Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power provides 6GK5216-0BA00-2AB2 quotations, manuals, selection, and exact-switch matching.

6GK5216-0BA00-2AB2

/ 4.9
1001 reviews | Need a Specific Revision?
Siemens 6GK5216-0BA00-2AB2 is a SCALANCE XB216 managed Layer 2 switch that connects sixteen 10/100 Mbit/s Ethernet devices and manages their network traffic.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 6GK5216-0BA00-2AB2
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 6GK5216-0BA00-2AB2

  • Manufacturer:
    Siemens
  • Part Number:
    6GK5216-0BA00-2AB2
  • Product Family:
    Siemens SCALANCE
  • Product Type:
    SCALANCE XB216 Managed Layer 2 Industrial Ethernet Switch
  • Stock:
    1
  • Copper Ethernet Ports:
    16 RJ45
  • Port Speed:
    10/100 Mbit/s
  • Console Port:
    1 RJ11
  • Management Port:
    1 RJ45
  • Rated Supply Voltage:
    24 V DC
  • Permissible Supply Range:
    19.2 to 28.8 V DC
  • Redundant Supply Connection:
    Supported
  • Maximum Current Consumption:
    0.28 A
  • Rated Power Loss:
    6.7 W
  • PROFINET Role:
    IO device, conformity class B
  • EtherNet/IP:
    Supported
  • Management Methods:
    CLI, web-based management and STEP 7
  • Redundancy Protocols:
    HRP, MRP, STP, RSTP and RSTP+
  • Security Functions:
    SSH, HTTPS and IEEE 802.1X
  • VLAN Capacity:
    257 maximum
  • Enclosure Protection:
    IP20
  • Operating Temperature:
    0 to 60 °C
  • Mounting Method:
    35 mm DIN rail
  • Weight:
    0.9744 lbs (0.442 kg)
  • Estimated shipping dimensions:
    14x12.5x15cm
  • Tariff Code:
    85176200
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Port Roles Managed Traffic Redundancy Paths Diagnostics

Features:

  • Sixteen copper ports forward 10/100 Mbit/s traffic between connected Industrial Ethernet devices.
  • CLI, web management and STEP 7 configure switching, VLAN and diagnostic behavior.
  • Dual supply input and ring protocols address power-path and network-path interruptions separately.
Managed forwarding keeps physical link state separate from VLAN and access decisions.

Console and management interfaces support service access without becoming ordinary field ports.

Port statistics, error counters and Syslog records help locate traffic or cabling problems.

The Siemens 6GK5216-0BA00-2AB2 SCALANCE XB216 Managed Ethernet Switch may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6GK5216-0BA00-2AB2 SCALANCE XB216 Ethernet Switch Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Separating traffic ports from service connections

  • Network ports: Sixteen RJ45 interfaces connect Industrial Ethernet stations at 10 or 100 Mbit/s.
  • Console access: The RJ11 console provides local service access for supported management tasks.
  • Management access: A dedicated RJ45 management path serves the configured administration interface.
  • Port state: Link and diagnostic information identify the physical condition of each connection.

Controlling which frames cross the switch

  • VLAN assignment: Port-based VLANs divide the physical switch into defined logical traffic groups.
  • Management tools: CLI, web-based management and STEP 7 apply and inspect the switch configuration.
  • Device protocols: PROFINET, EtherNet/IP and standard Ethernet services use the forwarding plane.
  • Access control: HTTPS, SSH and IEEE 802.1X protect supported management or endpoint access.

Distinguishing power backup from network recovery

  • Supply inputs: Redundant 24 V feeds keep the switch energized when one approved source is lost.
  • MRP and HRP: Ring protocols supervise eligible links and reopen a forwarding path after a break.
  • Spanning tree: STP and RSTP variants prevent loops while retaining alternate network routes.
  • Fault scope: A healthy power path cannot repair a broken cable, and a ring cannot replace lost supply power.

Tracing link, traffic and configuration conditions

  • Port counters: Packet and error statistics reveal activity on an individual copper interface.
  • Syslog events: Configured event messages record switch and network state changes.
  • PROFINET diagnosis: The controller can receive supported device and port diagnostic information.
  • Loopback check: Diagnostic functions help separate a local interface issue from an upstream network fault.
Description
Siemens 6GK5216-0BA00-2AB2 is the SCALANCE XB216 managed Layer 2 Industrial Ethernet switch that joins sixteen 10/100 Mbit/s copper devices in one controlled network segment. It forwards Ethernet frames between the RJ45 ports while exposing configuration and diagnostics to the automation system.

Management on 6GK5216-0BA00-2AB2 is separated from ordinary device traffic through its console and management access paths. CLI, web-based management and STEP 7 configure port behavior, VLANs and diagnostic reporting without turning those service connections into additional field-device ports.

Redundancy features in 6GK5216-0BA00-2AB2 address different failure points. The dual 24 V supply connection maintains switch power after one feed is lost, while HRP, MRP, STP and RSTP family protocols re-establish a forwarding path after an eligible network link changes.

For station diagnostics, 6GK5216-0BA00-2AB2 reports port states, traffic statistics, errors and Syslog events through the configured management service. VLAN and access-control settings determine which traffic can cross the switch, so an active link LED alone does not prove that two endpoints share an allowed logical path.
Alternative Names
6GK52160BA002AB2 6GK5 216-0BA00-2AB2 6GK5216 0BA00 2AB2 Siemens 6GK5216-0BA00-2AB2 SCALANCE XB216 6GK5216-0BA00-2AB2 XB216 Managed Switch 6GK5216-0BA00-2AB2 6GK5216-0BAOO-2AB2 6GKS216-0BA00-2AB2
Technical notes
Sixteen RJ45 data ports on Siemens 6GK5216-0BA00-2AB2 are distinct from its console and management connections. The redundant 24 V input preserves switch power when one approved supply path is lost, while ring protocols supervise network-path recovery.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why can a port link on 6GK5216-0BA00-2AB2 be active while devices still cannot communicate?
The 6GK5216-0BA00-2AB2 link LED confirms the physical connection but not VLAN or access permission. Compare both port assignments, endpoint addressing and any configured security rules before changing cables.
How do the redundant power terminals help 6GK5216-0BA00-2AB2?
The 6GK5216-0BA00-2AB2 can remain energized when one approved 24 V supply path is lost. This does not repair a failed Ethernet link, which requires the configured network-redundancy mechanism.
Which connection should be used for local service on 6GK5216-0BA00-2AB2?
Use the documented console or management access on 6GK5216-0BA00-2AB2 for the supported administration method. Do not count those service interfaces as additional field-device ports in the network design.
What should be reviewed after a ring fault on 6GK5216-0BA00-2AB2?
Check the 6GK5216-0BA00-2AB2 ring ports, protocol role and partner configuration, then read the diagnostics for the failed path. Every switch in the ring must use a compatible MRP or HRP arrangement.
How can traffic errors be traced on 6GK5216-0BA00-2AB2?
Read the 6GK5216-0BA00-2AB2 port statistics, error counters and Syslog events for the affected connection. Compare those records with cable condition, negotiated speed and endpoint traffic before replacing the switch.