1001 reviews | Need a Specific Revision?
Siemens 6GK5310-0FA10-2AA3 is a SCALANCE X310 managed Industrial Ethernet switch that links ten RJ45 segments and supervises redundant network paths.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 6GK5310-0FA10-2AA3
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 6GK5310-0FA10-2AA3

  • Manufacturer:
    Siemens
  • Part Number:
    6GK5310-0FA10-2AA3
  • Product Family:
    Siemens SCALANCE
  • Product Type:
    SCALANCE X310 Managed Industrial Ethernet Switch
  • Stock:
    1
  • RJ45 Ports:
    10
  • Fast Ethernet Ports:
    7 x 10/100 Mbps
  • Gigabit Ports:
    3 x 10/100/1000 Mbps
  • Transfer Rates:
    10, 100 and 1000 Mbps
  • Supply Voltage:
    24 V DC
  • Supply Range:
    18 to 32 V DC
  • Maximum Current Consumption:
    0.4 A
  • Rated Power Loss:
    9.6 W
  • Signaling Contact:
    2-pole terminal block
  • Configuration Medium:
    C-PLUG included
  • PROFINET Class:
    Conformance Class B
  • VLAN Capacity:
    255 maximum
  • Redundancy Protocols:
    MRP, HRP, STP, RSTP and MSTP
  • Protection Rating:
    IP30
  • Operating Temperature:
    -40 to +60 °C
  • Mounting:
    DIN rail, wall or S7-300 rail
  • Weight:
    3.199 lbs (1.451 kg)
  • Estimated shipping dimensions:
    30.5x48.3x4.4cm
  • Tariff Code:
    85176200
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Port Groups Ring Control Management Stored Settings

Features:

  • Seven Fast Ethernet and three gigabit RJ45 ports form the ten-port switching fabric.
  • PROFINET, VLAN and management functions separate process communication from administration.
  • MRP, HRP and spanning-tree options provide distinct redundancy methods.
Frames are forwarded according to port, VLAN and redundancy configuration rather than connector speed alone.

Controller diagnostics and switch-management protocols present different views of the same device.

The signaling contact and C-PLUG keep alarm reporting and stored configuration outside ordinary Ethernet traffic.

The Siemens 6GK5310-0FA10-2AA3 SCALANCE X310 Switch may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6GK5310-0FA10-2AA3 SCALANCE X310 Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Using Fast Ethernet and gigabit paths together

  • Fast Ethernet group: Seven RJ45 ports negotiate 10 or 100 Mbps links.
  • Gigabit group: Three RJ45 ports extend negotiation to 1000 Mbps.
  • Shared fabric: All ten ports participate in the configured managed switching structure.
  • End-point check: Cable category and the partner port determine the negotiated speed of each link.

Choosing one consistent redundancy method

  • MRP path: Media Redundancy Protocol can operate with the integrated redundancy manager.
  • HRP path: High Speed Redundancy supports manager and standby arrangements.
  • Tree path: STP, RSTP and MSTP control loops in spanning-tree topologies.
  • Configuration rule: Ports and partners must use the same intended redundancy design.

Separating configuration and controller diagnostics

  • Web and CLI: Browser and command-line interfaces provide device administration.
  • SNMP path: SNMP versions 1, 2 and 3 expose management information to monitoring tools.
  • PROFINET view: Conformance Class B diagnostics integrate the switch with the automation project.
  • Traffic control: Port mirroring, RMON and statistics support analysis without becoming process-data channels.

Keeping configuration on removable media

  • Included medium: The supplied C-PLUG can hold the device configuration.
  • Hardware separation: Stored settings remain separate from the switch electronics.
  • Identity match: The receiving hardware must be the intended SCALANCE X310 order number.
  • Commissioning check: Port, VLAN and redundancy behavior are verified after the stored configuration loads.
Description
Siemens 6GK5310-0FA10-2AA3 is the SCALANCE X310 managed Industrial Ethernet switch that combines seven Fast Ethernet RJ45 ports with three gigabit RJ45 ports for segmented plant networks.

Traffic entering 6GK5310-0FA10-2AA3 follows the configured VLAN, forwarding and redundancy rules before leaving another port. PROFINET IO device operation exposes switch diagnostics to the controller, while web, CLI and SNMP management handle separate configuration tasks.

The redundancy functions of 6GK5310-0FA10-2AA3 cover managed ring and spanning-tree paths. The active protocol determines which links forward frames normally and which path is released after a network interruption.

Power reaches 6GK5310-0FA10-2AA3 through its four-pole terminal block, and the two-pole signaling contact transfers a configured state to external monitoring. The included C-PLUG stores device configuration separately from the base switch.

Mounted on a DIN rail, wall or S7-300 rail, 6GK5310-0FA10-2AA3 operates as an IP30 device within the stated cabinet temperature range. Shipboard use adds the documented restriction against 35 mm rail mounting.
Alternative Names
6GK53100FA102AA3 6GK5310 0FA10 2AA3 6GK5 310-0FA10-2AA3 Siemens 6GK53100FA102AA3 SCALANCE X310 6GK5310-0FA10-2AA3 6GK5310-0FA10-2AA3 Ethernet Switch 6GK531O-0FA10-2AA3 6GK5310-OFA10-2AA3
Technical notes
Three gigabit uplinks and seven Fast Ethernet ports share the managed switching fabric of Siemens 6GK5310-0FA10-2AA3, while its signaling contact reports device conditions externally.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why can a device connected to a gigabit port on 6GK5310-0FA10-2AA3 still link at 100 Mbps?
The gigabit ports of 6GK5310-0FA10-2AA3 negotiate with the remote device and cable, so a 100 Mbps partner or unsuitable cabling limits the result. Check both endpoints rather than the switch label alone.
Which redundancy setting should be checked when a loop blocks traffic on 6GK5310-0FA10-2AA3?
Identify whether 6GK5310-0FA10-2AA3 is configured for MRP, HRP or a spanning-tree method, then compare the partner ports to that same design. Mixing ring roles can leave an unintended path blocked.
How does the C-PLUG help when a configured 6GK5310-0FA10-2AA3 is exchanged?
The included C-PLUG can retain the configuration outside 6GK5310-0FA10-2AA3. Confirm the exact receiving switch identity and verify ports, VLANs and redundancy after the stored settings are read.
What does the signaling contact on Siemens 6GK5310-0FA10-2AA3 report?
The contact on Siemens 6GK5310-0FA10-2AA3 transfers the configured device condition to external monitoring. It does not replace the detailed fault information provided through PROFINET or management protocols.
Can 6GK5310-0FA10-2AA3 be mounted on a standard rail in every certified installation?
No. Although 6GK5310-0FA10-2AA3 supports 35 mm DIN-rail mounting, the datasheet states that this method is not permitted for shipbuilding use. Select the mounting method for the actual approval context.
Where should a missing controller diagnostic be traced on 6GK5310-0FA10-2AA3?
For 6GK5310-0FA10-2AA3, confirm its PROFINET device identity and project configuration before changing physical port wiring. Web or SNMP access can work even when the controller-side device assignment is wrong.