Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Discontinued / Obsolete by OEM
    For 6GK5324-0GG10-3AR2, Apter Power can coordinate quotations, manual access, and SCALANCE model matching.

6GK5324-0GG10-3AR2

/ 4.9
1001 reviews | Need a Specific Revision?
Built for 19-inch network racks, Siemens 6GK5324-0GG10-3AR2 is a SCALANCE XR324-12M managed Industrial Ethernet switch that links modular copper or fiber segments and supervises redundant networks.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 6GK5324-0GG10-3AR2
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 6GK5324-0GG10-3AR2

  • Manufacturer:
    Siemens
  • Part Number:
    6GK5324-0GG10-3AR2
  • Product Family:
    Siemens SCALANCE
  • Product Type:
    SCALANCE XR324-12M Managed Industrial Ethernet Switch
  • Stock:
    1
  • Transfer Rate:
    10/100/1000 Mbit/s
  • Media Module Slots:
    12
  • Maximum Electrical Ports:
    24
  • Maximum Optical Ports:
    24
  • Operator Console:
    1 x RJ11
  • Signaling Contact:
    1 x 2-pole connection
  • C-PLUG:
    Included
  • Rated Supply Voltage:
    230 V AC
  • Supply Voltage Range:
    85-264 V AC
  • Maximum Current Consumption:
    0.8 A
  • Power Consumption:
    50 W
  • Input Fuse:
    3.15 A / 250 V
  • PROFINET Conformance:
    Class B
  • VLAN Capacity:
    Up to 255
  • Management Access:
    CLI, WBM, SNMP v1/v2/v3
  • Network Redundancy:
    HRP, MRP, STP, RSTP, MSTP, PRP
  • Degree of Protection:
    IP20
  • Operating Temperature:
    -40 to 70 °C, subject to media-module and mounting limits
  • Weight:
    15.21 lbs (6.9 kg)
  • Estimated shipping dimensions:
    30.5x48.3x4.4cm
  • Tariff Code:
    85176200
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Media Modules Redundancy Network Setup Diagnostics

Features:

  • Twelve media-module positions create a selectable copper or fiber port layout.
  • Managed 10/100/1000 Mbit/s traffic is carried through the installed two-port modules.
  • Integrated redundancy functions supervise alternate paths in a managed Industrial Ethernet network.
The one-unit rack format places media modules, indicators, and service access on the front of the switch.

Each installed module contributes its own pair of network connections, so empty positions do not represent fixed active ports.

Stored configuration and runtime fault reporting are handled separately through the C-PLUG, LEDs, and signaling contact.

The Siemens 6GK5324-0GG10-3AR2 SCALANCE XR324-12M Managed Industrial Ethernet Switch may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6GK5324-0GG10-3AR2 SCALANCE XR324-12M Managed Industrial Ethernet Switch Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Modular Port Arrangement

  • Slot role: Each front position receives a two-port media module rather than exposing a permanently assigned connector pair.
  • Media choice: The installed module determines whether its two connections carry electrical or optical Ethernet.
  • Port build: Network capacity is assembled across the occupied positions, so the configured port mix follows the selected modules.
  • Front access: Cabling and module placement remain accessible from the rack front for the installed network layout.

Managed Recovery Paths

  • Ring control: The integrated redundancy manager coordinates supported ring structures instead of requiring an external ring controller.
  • Industrial rings: HRP and MRP functions provide ring-specific recovery procedures for compatible network designs.
  • Tree control: STP, RSTP, and MSTP manage alternate bridged paths and prevent unintended forwarding loops.
  • Parallel paths: PRP and link aggregation are available when the surrounding network is engineered for those procedures.

Addressing and Segmentation

  • Device discovery: DCP and LLDP expose network identity and neighboring-device information during commissioning.
  • Address assignment: DHCP client functions and supported DHCP options participate in centralized address and boot-file handling.
  • Traffic groups: Port-based and dynamic VLAN functions separate logical traffic domains across the physical port arrangement.
  • Multicast handling: IGMP and GMRP functions control multicast membership and registration within the managed network.

Fault and Service Visibility

  • Port state: Port diagnostics expose connection-specific conditions without reducing all faults to one device-level message.
  • Local indication: Front LEDs separate switch and interface states for checks made at the rack.
  • Remote reporting: SNMP, SysLog, and PROFINET IO diagnostics deliver status information to supported management or automation tools.
  • External alarm: The two-pole signaling contact transfers a selected fault state to an external monitoring circuit.
Description
Siemens 6GK5324-0GG10-3AR2 is a SCALANCE XR324-12M managed Industrial Ethernet switch for a 19-inch rack. It concentrates modular network connections in a one-unit chassis and manages traffic, diagnostics, and redundancy for the connected Ethernet segments.

Across the front of 6GK5324-0GG10-3AR2, twelve positions accept two-port media modules. The module selected for each position determines whether that section of the switch presents electrical or optical connections, allowing the port arrangement to follow the installed cable media rather than a fixed connector mix.

Redundant paths on 6GK5324-0GG10-3AR2 are coordinated through its integrated ring-management functions and supported spanning-tree and media-redundancy procedures. VLAN, IGMP, DHCP, DCP, and LLDP functions organize addressing, segmentation, and device discovery without changing the physical module layout.

Local LEDs and the signaling contact of 6GK5324-0GG10-3AR2 separate visible device or port states from an external fault indication. Configuration and diagnostic access are available through the console, web-based management, command-line, SNMP, and PROFINET IO channels, while the C-PLUG remains part of the device configuration arrangement.
Alternative Names
6GK53240GG103AR2 6GK5324 0GG10 3AR2 6GK 5324-0GG10-3AR2 Siemens 6GK5324-0GG10-3AR2 6GK5324-0GG10-3AR2 SCALANCE XR324-12M 6GK5324-OGG10-3AR2 6GK5324-0GG1O-3AR2 SCALANCE XR324-12M 3AR2
Technical notes
Siemens 6GK5324-0GG10-3AR2 is a 19-inch SCALANCE XR324-12M managed switch with twelve front media-module positions. Its selected two-port modules form the copper or fiber network interfaces.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How should the copper and fiber port mix be determined for 6GK5324-0GG10-3AR2?
The port mix of 6GK5324-0GG10-3AR2 is determined by the two-port media module installed in each of its twelve front positions; use electrical or optical modules to match the planned cabling.
Does 6GK5324-0GG10-3AR2 provide twenty-four active network connectors without media modules?
No. 6GK5324-0GG10-3AR2 obtains its network connectors from the installed two-port media modules, so the populated module arrangement defines the active interfaces.
Which redundancy design must be checked before placing 6GK5324-0GG10-3AR2 into an existing ring?
Confirm whether the network uses HRP, MRP, STP, RSTP, MSTP, or PRP, because 6GK5324-0GG10-3AR2 must be configured for the procedure used by the surrounding switches.
Can a vertically mounted 6GK5324-0GG10-3AR2 use the same upper temperature limit as its standard rack orientation?
The vertical-mounting limit for 6GK5324-0GG10-3AR2 is lower than the general maximum, and the selected media modules can impose additional temperature restrictions.
What separates a local port problem from a device fault on 6GK5324-0GG10-3AR2?
6GK5324-0GG10-3AR2 combines port diagnostics and front LEDs with a separate signaling contact, allowing interface states and an external device-level alarm to be reviewed independently.
Which details should be recorded before replacing an installed 6GK5324-0GG10-3AR2?
Record the media-module population, port assignments, redundancy mode, VLAN configuration, and C-PLUG arrangement of 6GK5324-0GG10-3AR2 before matching the installed network layout.

Product Browsing History