Features:
- One wired Ethernet device is presented to the WLAN through client-mode operation.
- Dual-band 2.4 and 5 GHz radio support covers the documented IEEE 802.11 standards.
- IP65 housing, two supplied antennas and alternative power paths suit distributed installation.
The Ethernet port and the radio interface form opposite sides of one client bridge.
Security settings control the WLAN association without changing the identity of the attached wired station.
Antenna, connector and power choices must remain consistent with the environmental protection of the assembled unit.
The Siemens 6GK5744-1AA60-2AA0 SCALANCE W744-1PRO IWLAN Client may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6GK5744-1AA60-2AA0 SCALANCE W744-1PRO Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Connecting one wired station to the radio network
- Station side: The RJ45 interface connects the single wired Ethernet device.
- Wireless side: The radio associates the client module with the configured IWLAN.
- Role limit: The unit operates as an Ethernet client rather than an active access point.
- Address path: Traffic from the attached device crosses the established wireless association.
Aligning frequency, standard and region
- Frequency choice: The configured WLAN uses either the supported 2.4 GHz or 5 GHz channels.
- Standard set: IEEE 802.11a, b, g and h define the documented radio modes.
- Regional scope: This order configuration is specified for operation outside the USA.
- Rate boundary: The maximum listed wireless transfer rate is 54 Mbit/s.
Separating access protection from traffic handling
- Authentication: WPA2 and IEEE 802.11i protect the documented wireless association.
- Traffic class: IEEE 802.11e provides radio-network prioritization.
- Client identity: Security is applied at the wireless bridge used by the wired station.
- Commissioning check: Network credentials and radio mode must match the selected infrastructure.
Preserving the IP65 installation
- Antenna set: Two ANT795-4MR antennas belong to the supplied configuration.
- Connector seal: The included hybrid connector maintains the documented cable entry arrangement.
- Power route: Installation can use the stated 24 V DC or PoE supply option.
- Environmental limit: Enclosure protection depends on fully assembled, suitable connectors and antennas.