Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Discontinued / Obsolete by OEM
    Manuals, quotations, product selection, and model matching for 6GK5744-1AA60-2AA0 are coordinated by Apter Power.

6GK5744-1AA60-2AA0

/ 4.9
1001 reviews | Need a Specific Revision?
A wired industrial device joins a 2.4 or 5 GHz WLAN through Siemens 6GK5744-1AA60-2AA0, a SCALANCE W744-1PRO Ethernet client module.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 6GK5744-1AA60-2AA0
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 6GK5744-1AA60-2AA0

  • Manufacturer:
    Siemens
  • Part Number:
    6GK5744-1AA60-2AA0
  • Product Family:
    Siemens SCALANCE
  • Product Type:
    SCALANCE W744-1PRO IWLAN Ethernet Client Module
  • Stock:
    1
  • Wireless Role:
    Ethernet client
  • Client Capacity:
    1 wired station
  • Ethernet Interface:
    1 x RJ45
  • Wireless Standards:
    IEEE 802.11a/b/g/h
  • Frequency Bands:
    2.4 GHz and 5 GHz
  • Maximum Wireless Rate:
    54 Mbit/s
  • Security:
    WPA2 and IEEE 802.11i
  • Traffic Priority:
    IEEE 802.11e
  • Supplied Antennas:
    2 x ANT795-4MR
  • Power Options:
    24 V DC or Power over Ethernet
  • Hybrid Connector:
    IP67 connector included
  • Protection Rating:
    IP65
  • Operating Temperature:
    -20 to 60 °C
  • Weight:
    2.315 lbs (1.05 kg)
  • Estimated shipping dimensions:
    12.5x8x10cm
  • Tariff Code:
    85176200
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Client Bridge Radio Selection Security Priority Outdoor Assembly

Features:

  • One wired Ethernet device is presented to the WLAN through client-mode operation.
  • Dual-band 2.4 and 5 GHz radio support covers the documented IEEE 802.11 standards.
  • IP65 housing, two supplied antennas and alternative power paths suit distributed installation.
The Ethernet port and the radio interface form opposite sides of one client bridge.

Security settings control the WLAN association without changing the identity of the attached wired station.

Antenna, connector and power choices must remain consistent with the environmental protection of the assembled unit.

The Siemens 6GK5744-1AA60-2AA0 SCALANCE W744-1PRO IWLAN Client may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6GK5744-1AA60-2AA0 SCALANCE W744-1PRO Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Connecting one wired station to the radio network

  • Station side: The RJ45 interface connects the single wired Ethernet device.
  • Wireless side: The radio associates the client module with the configured IWLAN.
  • Role limit: The unit operates as an Ethernet client rather than an active access point.
  • Address path: Traffic from the attached device crosses the established wireless association.

Aligning frequency, standard and region

  • Frequency choice: The configured WLAN uses either the supported 2.4 GHz or 5 GHz channels.
  • Standard set: IEEE 802.11a, b, g and h define the documented radio modes.
  • Regional scope: This order configuration is specified for operation outside the USA.
  • Rate boundary: The maximum listed wireless transfer rate is 54 Mbit/s.

Separating access protection from traffic handling

  • Authentication: WPA2 and IEEE 802.11i protect the documented wireless association.
  • Traffic class: IEEE 802.11e provides radio-network prioritization.
  • Client identity: Security is applied at the wireless bridge used by the wired station.
  • Commissioning check: Network credentials and radio mode must match the selected infrastructure.

Preserving the IP65 installation

  • Antenna set: Two ANT795-4MR antennas belong to the supplied configuration.
  • Connector seal: The included hybrid connector maintains the documented cable entry arrangement.
  • Power route: Installation can use the stated 24 V DC or PoE supply option.
  • Environmental limit: Enclosure protection depends on fully assembled, suitable connectors and antennas.
Description
For a machine or cabinet device that lacks its own wireless interface, Siemens 6GK5744-1AA60-2AA0 is a SCALANCE W744-1PRO IWLAN Ethernet client that bridges one wired Ethernet station into an industrial WLAN.

The RJ45 side of 6GK5744-1AA60-2AA0 serves the attached station, while its radio uses the configured 2.4 GHz or 5 GHz network. The module operates as a client rather than providing an enabled access-point role.

Outdoor-style IP65 housing on 6GK5744-1AA60-2AA0 protects the electronics when the supplied antennas and documented connectors are installed correctly. Two ANT795-4MR antennas provide the radio connections specified for this order configuration.

Power for 6GK5744-1AA60-2AA0 can enter through the documented 24 V DC path or Power over Ethernet arrangement. WPA2 and IEEE 802.11i protect the wireless association, while IEEE 802.11e handles traffic priority on the radio network.
Alternative Names
6GK57441AA602AA0 6GK5744 1AA60 2AA0 6GK5 744-1AA60-2AA0 Siemens 6GK57441AA602AA0 SCALANCE W744-1PRO 6GK5744-1AA60-2AA0 6GK5744-1AA60-2AA0 IWLAN Client 6GK5744-1AA6O-2AA0 W744-1PRO Ethernet Client Module
Technical notes
The single Ethernet station behind Siemens 6GK5744-1AA60-2AA0 shares the selected IWLAN client association; confirm regional radio settings, antenna placement and the chosen power entry.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Can Siemens 6GK5744-1AA60-2AA0 create an access point for several clients?
No. Siemens 6GK5744-1AA60-2AA0 is the Ethernet-client configuration for one wired station and does not provide the enabled access-point role described for other SCALANCE variants.
Which frequency should be configured when 6GK5744-1AA60-2AA0 cannot join the WLAN?
Match the selected 2.4 or 5 GHz band and IEEE 802.11 mode on 6GK5744-1AA60-2AA0 to the infrastructure channel. Also verify that the regional radio settings permit that channel.
What protects the wireless association of 6GK5744-1AA60-2AA0?
The documented security set for 6GK5744-1AA60-2AA0 includes WPA2 and IEEE 802.11i. Credentials and authentication settings must agree with the target industrial WLAN.
Why must both antennas remain connected to 6GK5744-1AA60-2AA0?
The supplied configuration of 6GK5744-1AA60-2AA0 includes two ANT795-4MR antennas for its radio arrangement. Leaving a required antenna path open can impair the intended wireless connection.
Is a separate 24 V cable always required for 6GK5744-1AA60-2AA0?
Not in every documented arrangement. Siemens 6GK5744-1AA60-2AA0 supports the stated 24 V DC path or a Power over Ethernet option, but the connector and upstream source must match the chosen method.
How is the IP65 rating maintained when installing 6GK5744-1AA60-2AA0?
Use the specified antennas and sealed connector arrangement on 6GK5744-1AA60-2AA0, keep all entries fully assembled, and remain inside the documented temperature range. An open cable entry defeats the enclosure protection.