Siemens 6SN1118-0DK23-0AA2
Siemens 6SN1118-0DK23-0AA2
Siemens 6SN1118-0DK23-0AA2
Siemens 6SN1118-0DK23-0AA2
Siemens 6SN1118-0DK23-0AA2
Siemens 6SN1118-0DK23-0AA2
Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Discontinued / Obsolete by OEM
    Apter Power supports quotations, technical documents, and SIMODRIVE 611 configuration checks for 6SN1118-0DK23-0AA2.

6SN1118-0DK23-0AA2

/ 4.9
1001 reviews | Need a Specific Revision?
Siemens 6SN1118-0DK23-0AA2 SIMODRIVE 611D two-axis high-performance control unit.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 6SN1118-0DK23-0AA2
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 6SN1118-0DK23-0AA2

  • Manufacturer:
    Siemens
  • Part Number:
    6SN1118-0DK23-0AA2
  • Product Family:
    Siemens SIMODRIVE
  • Product Type:
    SIMODRIVE 611D 2-Axis Control Unit
  • Stock:
    1
  • Product family:
    Siemens SIMODRIVE 611D
  • Control scope:
    Two axes
  • Performance class:
    High Performance
  • Feedback:
    Direct measuring system
  • Weight:
    0.5 kg
  • Estimated shipping dimensions:
    4.5 x 13.6 x 31.5 cm
  • Tariff Code:
    8473309000
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Control Architecture Feedback Interface Safety Data Product Applications

Features:

  • Two-axis control: documented for the SIMODRIVE 611D architecture.
  • High-performance class: includes direct measuring-system feedback.
  • Machine-data control: firmware, axis parameters, and connector layout must match.
6SN1118-0DK23-0AA2 performs the documented two-axis control function within a SIMODRIVE 611D drive system.

The module should be compared with the machine backup, axis configuration, and feedback wiring before service.

Commissioning should verify both axes, measuring-system feedback, drive diagnostics, and safety functions.

For Siemens 6SN1118-0DK23-0AA2 SIMODRIVE 611D 2-Axis Control Unit, Apter Power supports quotations, technical documents, and installed-system configuration checks.
Siemens 6SN1118-0DK23-0AA2 SIMODRIVE 611D 2-Axis Control Unit Manuals,Datasheets,Link
Important Notice: Verify the complete catalog number, document revision, and installed-system configuration before use.
  • Two-axis high-performance control unit for the SIMODRIVE 611D system.
  • Confirm the machine data set and axis allocation before installation.
  • Keep the installed firmware context with the service log.
  • Review both axis channels together when diagnosing asymmetric motion behavior.
  • Documented for direct measuring-system feedback.
  • Verify feedback connector type and axis assignment against machine drawings.
  • Inspect feedback cables and shielding before commissioning.
  • Use drive diagnostics to separate feedback faults from axis-data errors.
  • Siemens safety data lists a PFH value of 60 x 10^-9 per hour for this control-board class.
  • Machine-level safety validation remains required after service.
  • Follow the drive discharge and lockout procedure before handling.
  • Include both axes in the functional safety test after controller work.
  • Two-axis motion control in installed SIMODRIVE 611D systems.
  • Machine-tool and production-equipment drive maintenance.
  • Service requiring direct measuring-system feedback and verified machine data.
  • Motion systems where the original axis parameters and machine backup are available.
Description
6SN1118-0DK23-0AA2 is a Siemens SIMODRIVE 611D two-axis high-performance control unit documented for direct measuring-system feedback.

Within an installed drive, 6SN1118-0DK23-0AA2 links two-axis control with the machine's direct measuring-system feedback architecture.

For maintenance planning, 6SN1118-0DK23-0AA2 is best selected with the original firmware context, axis data, connectors, and machine backup available.
Alternative Names
Siemens 6SN1118-0DK23-0AA2 6SN11180DK230AA2 6SN1118 0DK23 0AA2
Technical notes
Siemens documentation identifies 6SN1118-0DK23-0AA2 as a SIMODRIVE 611D two-axis high-performance control unit with direct measuring-system feedback. Siemens also lists this catalog number among discontinued SIMODRIVE 611 components. Confirm firmware context, axis configuration, connectors, and machine data before installation.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What control function does 6SN1118-0DK23-0AA2 provide?
It provides two-axis high-performance control with direct measuring-system feedback in the SIMODRIVE 611D architecture.
How does the discontinued status of 6SN1118-0DK23-0AA2 affect a service project?
The project should plan around the exact installed catalog number, retained machine data, and available technical documentation.
Why is direct measuring feedback important for 6SN1118-0DK23-0AA2?
It closes the position or speed feedback path used by the two controlled axes, so interface and assignment accuracy matter.
Which machine data should accompany 6SN1118-0DK23-0AA2?
Axis allocation, firmware context, feedback type, connector details, and a current machine backup provide the useful commissioning baseline.
What can cause a fault after installing 6SN1118-0DK23-0AA2?
Common starting points are axis-data inconsistency, feedback assignment, connector condition, cable shielding, and firmware context.
How should the safety context of 6SN1118-0DK23-0AA2 be handled?
Use the documented control-board safety data within the machine's complete safety assessment and functional test.