Features:
- Attenuates conducted emissions across the 150 kHz to 30 MHz range.
- Operates with the line reactor assigned to the selected Line Module.
- Allows horizontal or vertical installation without changing its rating.
Select 6SL3000-0BE23-6DA1 by Line Module power and topology rather than by enclosure appearance.
The LINE and LOAD markings keep the incoming supply separate from the filtered converter path.
A grounded-neutral supply or an isolating transformer defines the permitted system boundary.
The Siemens 6SL3000-0BE23-6DA1 Basic Line Filter may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6SL3000-0BE23-6DA1 Basic Line Filter Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Conducted-Noise Path
- Frequency focus: The filter acts mainly from 150 kHz to 30 MHz.
- Reactor relationship: Filtering is coordinated with the associated line reactor.
- System assessment: Cable-length limits belong to the complete Line Module combination.
- Compliance boundary: Final machine EMC conformity remains a system-level responsibility.
Power-Path Separation
- Incoming side: L1, L2 and L3 receive the three-phase supply.
- Outgoing side: L1′, L2′ and L3′ feed the filtered downstream path.
- Conductor interface: Both sides use three-pole screw terminals for 35 mm² conductors.
- Clamping range: The main terminals are tightened between 3.2 and 3.7 Nm.
Supply and PE Rules
- Permitted networks: Direct connection requires a TN or TT supply with grounded neutral.
- Other systems: An isolating transformer establishes the required supply boundary.
- PE attachment: Either M6 protective-conductor stud may be used.
- Routing restriction: The PE connection cannot be looped through to the line reactor.
Rating Alignment
- Basic Line path: The documented pairing is a 40 kW Basic Line Module.
- Smart Line path: The same filter article is assigned to a 36 kW Smart Line Module.
- Active Line path: A 36 kW Active Line Module is included in the product assignment.
- Selection check: Power class and module topology must both match before connection.