1001 reviews | Need a Specific Revision?
The Siemens 6SL3254-0AM00-0AA0 is a 64 MB Multi Media Card used to store and transfer parameter sets for supported SINAMICS and ET 200 frequency converters.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 6SL3254-0AM00-0AA0
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 6SL3254-0AM00-0AA0

  • Manufacturer:
    Siemens
  • Part Number:
    6SL3254-0AM00-0AA0
  • Product Family:
    Siemens SINAMICS
  • Product Type:
    SINAMICS 64 MB Multi Media Card
  • Stock:
    1
  • Storage Capacity:
    64 MB
  • Supported File System:
    FAT
  • Storage Function:
    External removable parameter storage
  • Transfer Directions:
    EEPROM upload and EEPROM download
  • Supported Control Families:
    CU240E, CU240S, CU240D, ET 200S FC, ET 200pro FC
  • Commissioning Mode:
    P0010 = 30
  • Clone File Selection:
    P0804
  • Manual Upload Command:
    P0802 = 2
  • Manual Download Command:
    P0803 = 2
  • Transfer State:
    Control unit powered and converter Ready
  • Weight:
    0.11 lbs (0.05 kg)
  • Estimated shipping dimensions:
    7.5×9.5×0.4cm
  • Tariff Code:
    85235191
  • Country of origin:
    Taiwan
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Parameter Upload Manual Download File Format Drive Families

Features:

  • The removable 64 MB MMC stores converter parameter sets outside the control-unit EEPROM.
  • Manual upload and download commands move a selected clone file in either direction.
  • FAT formatting is required for recognition by supported SINAMICS and ET 200 converters.
Siemens 6SL3254-0AM00-0AA0 provides a removable parameter carrier for supported first-generation drive control units.

Clone-file selection remains separate from the upload or download command, preserving a defined transfer direction for each operation.

Power, Ready-state, commissioning-mode, and file-system conditions must all be satisfied before the card transfer starts.

Apter Power assists with pricing and access to official manufacturer documentation for Siemens 6SL3254-0AM00-0AA0 SINAMICS 64 MB Multi Media Card.
Siemens 6SL3254-0AM00-0AA0 SINAMICS 64 MB Multi Media Card Manuals, Datasheets, Links Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

6SL3254-0AM00-0AA0 EEPROM Upload

  • Power condition: The control unit must remain powered before the transfer starts.
  • Operating state: Ready state is required for the manual procedure.
  • Commissioning mode: P0010 = 30 prepares the transfer function.
  • Upload command: P0802 = 2 copies EEPROM parameters to the selected clone file.

6SL3254-0AM00-0AA0 Parameter Restore

  • File selection: P0804 chooses the clone file to be read from the card.
  • Download command: P0803 = 2 starts the transfer to converter EEPROM.
  • Target path: The selected parameter set is written into the supported control unit.
  • Prerequisite: Power and Ready-state conditions apply before the command.

6SL3254-0AM00-0AA0 Storage Compatibility

  • Supported format: The converter recognizes the card when it uses FAT.
  • FAT32 boundary: FAT32 formatting is not supported.
  • NTFS boundary: NTFS formatting is not supported.
  • Card capacity: The removable Multi Media Card provides 64 MB of storage.

6SL3254-0AM00-0AA0 Control Coverage

  • CU240E: The MMC is listed for the CU240E control-unit family.
  • CU240S and CU240D: Both control-unit families are included in the documented coverage.
  • ET 200S FC: The card supports external parameter storage for ET 200S FC.
  • ET 200pro FC: ET 200pro FC is also part of the documented converter coverage.
Description
Siemens 6SL3254-0AM00-0AA0 is a removable 64 MB Multi Media Card within the SINAMICS parameter-storage architecture. It provides external storage for converter parameter sets used by supported CU240 and ET 200 frequency-converter control units.

Parameter data can be uploaded from converter EEPROM to 6SL3254-0AM00-0AA0 and later downloaded from the card into a supported control unit. The saved set therefore moves through the card rather than being re-entered at the destination.

Manual transfer with 6SL3254-0AM00-0AA0 requires the converter to be powered and in the Ready state. P0010 selects commissioning mode, P0804 selects the clone file, and P0802 or P0803 determines the upload or download direction.

The file-system boundary for 6SL3254-0AM00-0AA0 is FAT. FAT32 and NTFS are outside the supported format, so the card must retain FAT formatting before a parameter transfer is attempted.
Alternative Names
6SL32540AM000AA0 6SL 3254 0AM00 0AA0 6SL3254 0AM00 0AA0 Siemens 6SL3254-0AM00-0AA0 6SL3254-0AM00-0AA0 MMC Siemens 6SL3254-0AM00-0AA0 Memory Card 6SL3254-OAMOO-OAAO 6SL3254 0AM00 0AA0 SINAMICS 64MB Card
Technical notes
Siemens 6SL3254-0AM00-0AA0 must use FAT formatting, not FAT32 or NTFS. Start a manual parameter transfer only with the converter powered and in the Ready state.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why is 6SL3254-0AM00-0AA0 not recognized after it was reformatted on a computer?
Check the file system first: Siemens 6SL3254-0AM00-0AA0 must use FAT. FAT32 and NTFS are outside the documented converter-storage format.
Why does an upload to Siemens 6SL3254-0AM00-0AA0 fail to start?
Confirm that the converter is powered and Ready, set P0010 = 30, select the intended clone file with P0804, and then issue P0802 = 2 for 6SL3254-0AM00-0AA0.
How can the wrong parameter file be avoided when restoring from 6SL3254-0AM00-0AA0?
Before issuing P0803 = 2, verify the P0804 clone-file selection and confirm that the target control unit belongs to the supported family for Siemens 6SL3254-0AM00-0AA0.
Can 6SL3254-0AM00-0AA0 be used to move settings to a replacement control unit?
Yes, when the replacement belongs to a supported control family. Upload the source EEPROM set to 6SL3254-0AM00-0AA0, select that file, and use the documented download procedure at the replacement unit.
Which command direction should be used when parameters must be copied from the converter to 6SL3254-0AM00-0AA0?
For Siemens 6SL3254-0AM00-0AA0, P0802 = 2 uploads from converter EEPROM to the card; P0803 = 2 performs the opposite download direction.