Features:
- Two High Feature channels measure ten thermocouple families or a direct ±80 mV signal.
- Internal or channel-specific external compensation follows the installed terminal arrangement.
- Selectable interference suppression, smoothing, and diagnostics govern conversion and fault reporting.
Siemens 6ES7134-4NB00-0AB0 combines thermocouple linearization and high-resolution conversion in a narrow ET 200S module.
Sensor-family selection and reference-junction compensation form one measurement configuration rather than independent assumptions.
The chosen suppression frequency and smoothing stage set the timing behavior before diagnostic status and measured data reach the station.
Apter Power assists with pricing and access to official manufacturer documentation for Siemens 6ES7134-4NB00-0AB0 SIMATIC ET 200S Thermocouple Input Module.
Siemens 6ES7134-4NB00-0AB0 SIMATIC ET 200S Thermocouple Input Module Manuals, Datasheets, Links
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
6ES7134-4NB00-0AB0 Sensor Selection
- Thermocouple range: Types B, C, E, J, K, L, N, R, S, and T are configurable.
- Millivolt mode: A direct ±80 mV measurement range is also available.
- Linearization: The selected thermocouple family determines the characteristic curve.
- Resolution: Both channels convert measurements with 15 bits plus sign.
6ES7134-4NB00-0AB0 Reference Junction
- Internal method: Specified AT terminal modules provide internal compensation.
- External method: One compensation box is assigned to each channel.
- Parameter choice: The compensation mode is selected in the module configuration.
- Installation match: The setting must correspond to the installed terminal arrangement.
6ES7134-4NB00-0AB0 Timing Sequence
- Frequency rejection: Interference suppression can be set for 50 or 60 Hz.
- Integration time: The corresponding intervals are 20 ms or 16.7 ms.
- Conversion time: Per-channel conversion takes 80 ms or 66 ms respectively.
- Smoothing: Four stages are available for the transferred measurement.
6ES7134-4NB00-0AB0 Fault Evaluation
- Wire break: Sensor-circuit continuity can be monitored.
- Group error: The red SF indicator reports a module group fault.
- Range status: Overflow and underflow identify values beyond the configured range.
- Parameter control: Diagnostic functions are assigned in the module configuration.