Features:
- Two LC multimode-fiber ports connect the ET 200iSP station to PROFINET IO.
- MRP, S2 and R1 provide separate media and system-redundancy options.
- Stored parameters and substitute values are distributed during station startup.
Siemens
6ES7152-1BA00-0AB0 sits at the head of the ET 200iSP station and exchanges controller data with the installed electronic modules.
The integrated fiber switch in
6ES7152-1BA00-0AB0 uses two LC ports for multimode links, keeping PROFINET communication separate from the station's internal module bus.
Status indicators on
6ES7152-1BA00-0AB0 separate run, error, maintenance, link and supply conditions so commissioning can identify the affected path.
The Siemens 6ES7152-1BA00-0AB0 ET 200iSP IM 152-1PN Interface Module may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6ES7152-1BA00-0AB0 ET 200iSP IM 152-1PN Interface Module Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
PROFINET Exchange Through the Station Head
- Controller input: The PROFINET IO controller sends network data to the IM 152-1PN interface.
- Output preparation: 6ES7152-1BA00-0AB0 prepares controller data for the station's electronic modules.
- Input return: Data from the electronic modules returns through the same station interface.
- Address allocation: The station provides 244 bytes for inputs and 244 bytes for outputs.
Optical Links and Redundancy Modes
- Optical switch: Two LC ports form the integrated multimode-fiber PROFINET switch.
- Fiber distance: The path can extend to 3000m with the documented cable types.
- Media redundancy: MRP supplies the ring redundancy function.
- System redundancy: S2 and R1 support the documented redundant controller architectures.
Parameter Transfer Before Data Exchange
- Parameter delivery: Stored parameters are sent to the electronic modules during station startup.
- Substitute outputs: Saved substitute values are applied before controller data exchange begins.
- Live outputs: Controller data replaces substitute values after the IO controller enters data exchange.
- Firmware level: Version V1.0.4 identifies the documented operating configuration.
Status Indicators and Hazardous-Area Marking
- Module state: RUN, ERROR and MAINT distinguish operation, fault and maintenance conditions.
- Fiber state: LINK indicators report the condition of the two optical connections.
- Supply state: PWR reports the interface module's power condition.
- Ex marking: Ex ib IIC T4 Gb and Ex ib I Mb apply to the documented hazardous-area installation.