Siemens 6ES7193-6AR00-0AA0 is the SIMATIC ET 200SP BA 2xRJ45 BusAdapter with two PROFINET copper ports. It supports line-topology connections within the compatible ET 200SP station.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 6ES7193-6AR00-0AA0
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 6ES7193-6AR00-0AA0

  • Manufacturer:
    Siemens
  • Part Number:
    6ES7193-6AR00-0AA0
  • Product Family:
    Siemens Simatic ET 200SP
  • Product Type:
    SIMATIC ET 200SP BA 2xRJ45 BusAdapter
  • Stock:
    1
  • Product designation:
    BA 2xRJ45
  • Network interface:
    PROFINET, two RJ45 ports
  • Maximum copper segment:
    100 m
  • Weight:
    0.054 kg
  • Estimated shipping dimensions:
    6.7x7.5x2.9cm
  • Tariff Code:
    85366990
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Port Layout Network Cabling ET 200SP Fit Product Applications

Features:

  • Two-port PROFINET: Provides two RJ45 copper interfaces for an ET 200SP station.
  • Line topology: Allows the network path to continue through the compatible station.
  • Exact station fit: Mounts as the BA 2xRJ45 option for supported ET 200SP interface hardware.
The BusAdapter defines the physical network connection, while the interface module and project retain the station configuration.

Both RJ45 paths, cable condition, shielding, and station name should be checked during commissioning.

The complete Siemens order number is the safest boundary when a visually similar BusAdapter is offered.

Apter Power supports Siemens 6ES7193-6AR00-0AA0 SIMATIC ET 200SP BA 2xRJ45 BusAdapter quotations, technical documents, and network matching.
Siemens 6ES7193-6AR00-0AA0 SIMATIC ET 200SP BA 2xRJ45 BusAdapter Manuals, Datasheets, Links
Important Notice: Manuals and supporting documents are provided for identification and engineering review. Confirm the complete product code before ordering.
  • Port count: Two RJ45 ports provide the copper PROFINET path.
  • Topology: The ports support line connections through the ET 200SP station.
  • Identity: Use BA 2xRJ45 and the full article number together.
  • Segment length: Siemens specifies copper segments up to 100 m.
  • Connection quality: Check cable category, shielding, bend condition, and RJ45 seating.
  • Troubleshooting: Compare link indicators on both sides before replacing hardware.
  • Interface module: Confirm the BusAdapter option supported by the installed interface module.
  • Station record: Retain the configured device name and network assignment.
  • Commissioning: Verify communication with upstream and downstream stations after service.
  • Distributed I/O: Connects ET 200SP remote I/O stations to PROFINET.
  • Machine networks: Supports compact line topologies inside automation cabinets.
  • Maintenance spares: Restores an installed BA 2xRJ45 position when the exact station design is retained.
Description
The Siemens 6ES7193-6AR00-0AA0 is a SIMATIC ET 200SP BA 2xRJ45 BusAdapter that provides the station’s copper PROFINET connection. Its two RJ45 ports allow the compatible interface module to continue a line topology without a separate cabinet switch.

For an installed ET 200SP station, 6ES7193-6AR00-0AA0 should be matched to the interface-module position, connector orientation, network topology, and approved copper segment. Siemens specifies PROFINET transmission through the two 100 Mbps RJ45 ports, with cable length considered at the network-design level.

During replacement or expansion, 6ES7193-6AR00-0AA0 should be commissioned with the station name, network path, and link diagnostics checked against the saved project. Apter Power can support exact-model quotations, technical documentation, and configuration review.
Alternative Names
6ES71936AR000AA0 6ES7 193-6AR00-0AA0 6ES7193 6AR00 0AA0 6ES7193-6AROO-0AA0 6ES7193-6AR00-OAA0 Siemens BA 2xRJ45 BA 2xRJ45 ET 200SP 6ES7I93-6AR00-0AA0
Technical notes
For 6ES7193-6AR00-0AA0, keep the BusAdapter identity linked to the ET 200SP interface module, station name, copper topology, and connector photographs. Link loss should be isolated across both RJ45 paths before the adapter is condemned. Apter Power can review these records before preparing documents and a quotation.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What does 6ES7193-6AR00-0AA0 do in an ET 200SP station?
It provides the two-port RJ45 PROFINET connection used by a compatible ET 200SP interface module.
Can 6ES7193-6AR00-0AA0 be selected only by its two RJ45 connectors?
The connector count alone is insufficient; the complete order number, supported ET 200SP interface module, station layout, and orientation should agree.
How should a line topology be checked after installing 6ES7193-6AR00-0AA0?
Commissioning should compare both link indicators, the station name, neighboring-device communication, and the copper segment with the network project.
What can cause intermittent communication around 6ES7193-6AR00-0AA0?
Damaged patch leads, loose RJ45 seating, excessive cable length, shielding problems, or an incorrect station configuration can interrupt the path.
Does 6ES7193-6AR00-0AA0 guarantee redundancy because it has two ports?
Two ports support a line topology, while redundancy depends on the complete network design and controller configuration.
What should accompany an RFQ for 6ES7193-6AR00-0AA0?
A useful request includes the station label, interface-module number, network topology, quantity, destination, and required documentation.