Features:
- The 15.4-inch widescreen panel combines analog-resistive touch input with high-resolution visualization.
- PROFINET and MPI/PROFIBUS DP paths connect the operator station to supported controller networks.
- WinCC Comfort runtime organizes alarms, recipes, trends, archives, and process values on the panel.
Siemens 6AV2124-0QC02-0AX2 is the TP1500 Comfort order number for a 15.4-inch touch-operated SIMATIC HMI station.
Its switched and independent Ethernet connections work alongside the combined RS 422/485 port to cover the documented network paths.
The configured runtime stores HMI project content locally and uses USB or SD media for supported transfer and service operations.
The Siemens 6AV2124-0QC02-0AX2 SIMATIC HMI TP1500 Comfort Panel may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6AV2124-0QC02-0AX2 SIMATIC HMI TP1500 Comfort Panel Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
How Touch Input Reaches the Runtime
- The analog-resistive surface provides single-point touch operation for configured buttons, fields, and navigation objects.
- The widescreen layout accommodates process pictures, alarms, trends, and recipe views within one local station.
- Direct-touch-key functions can be assigned as controller inputs when the project uses that documented mechanism.
Controller and Service Connections
- A switched Ethernet pair supports line-oriented network connections through one panel interface.
- The independent Ethernet port provides a separate path rather than a third port on the same switch.
- The combined serial interface carries the supported MPI or PROFIBUS DP connection selected for the project.
Routes Used to Move Panel Data
- Ethernet transfer links the engineering station to the configured panel address.
- USB connections accept supported transfer media and peripherals without occupying an SD position.
- Two SD slots separate removable panel storage roles from the onboard configuration memory.
Functions Managed at the Operator Station
- Alarm handling presents current and historical events within the engineered runtime.
- Recipe and trend objects organize operator-adjustable data and time-based process views.
- OPC UA client and server services are available when they are enabled and configured in the project.