Features:
- A 7-inch touch display and eight illuminated function keys share the handheld operator surface.
- Enabling, key-switch, pushbutton, and emergency controls support the approved safety architecture.
- PROFINET, USB, and SD-card interfaces separate controller, peripheral, and storage paths.
The 6AV2125-2GB23-0AX0 combines mobile HMI operation with hardware controls intended for a safety-related panel system.
Its PROFIsafe function depends on the complete compatible cable, connection box, controller, and configured safety project.
WinCC engineering supplies screens, alarms, recipes, archives, and user administration for the panel runtime.
The Siemens 6AV2125-2GB23-0AX0 SIMATIC HMI KTP700F Mobile Operator Panel may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6AV2125-2GB23-0AX0 SIMATIC HMI KTP700F Mobile Operator Panel Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Panel-Side Safety Operating Elements
- Enabling device: A three-stage button supplies the documented acknowledgement path.
- Emergency control: The enclosure includes the specified emergency-stop or STOP element.
- Key selection: A key-operated switch provides a separate physical mode input.
- System boundary: Safety performance requires the complete approved PROFIsafe installation.
Touch and Hardware Key Interaction
- Visual area: The 7-inch TFT presents an 800 x 480 project screen.
- Touch entry: Onscreen controls and keyboards handle configured process input.
- Function keys: Eight illuminated keys remain available outside the touchscreen.
- Pushbutton: The illuminated physical button supplies another project-assigned operator input.
Engineering and Removable Storage
- Engineering route: WinCC Comfort V13 SP1 or later configures the HMI project.
- Runtime memory: The panel provides 12 MB of user data memory.
- SD path: The memory-card slot supports removable project and runtime data handling.
- USB path: USB 2.0 connects supported peripherals or removable media separately from Ethernet.
Controller and Service Communication
- Primary network: One PROFINET/Industrial Ethernet interface carries controller traffic.
- Safety channel: PROFIsafe transports the configured safety-related communication.
- Open protocols: TCP/IP services, Modbus, and EtherNet/IP are available within the documented functions.
- Excluded interface: The panel does not provide a separate serial or PROFIBUS connection.