6AV6642-0AA11-0AX1

/ 4.9
1001 reviews | Need a Specific Revision?
Siemens 6AV6642-0AA11-0AX1 is a SIMATIC TP 177A operator panel that displays process screens and exchanges operator commands over MPI or PROFIBUS DP.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 6AV6642-0AA11-0AX1
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 6AV6642-0AA11-0AX1

  • Manufacturer:
    Siemens
  • Part Number:
    6AV6642-0AA11-0AX1
  • Product Family:
    Siemens Simatic HMI
  • Product Type:
    SIMATIC TP 177A 5.7-Inch Touch Panel
  • Stock:
    1
  • Display Technology:
    STN blue mode
  • Screen Diagonal:
    5.7 in
  • Display Resolution:
    320 x 240 pixels
  • Touch Technology:
    Analog resistive
  • Processor:
    ARM
  • User Data Memory:
    512 KB
  • Communication Interfaces:
    1 x RS422 and 1 x RS485
  • Maximum RS485 Data Rate:
    1.5 Mbit/s
  • Supported Fieldbus:
    MPI / PROFIBUS DP
  • Rated Current Consumption:
    0.24 A
  • Typical Power Input:
    6 W
  • Front Protection:
    IP65 / NEMA 4X when installed
  • Rear Protection:
    IP20
  • Operating Temperature:
    0 to 50 °C
  • Storage and Transport Temperature:
    -20 to 60 °C
  • Maximum Runtime Languages:
    5
  • Maximum Project Languages:
    32
  • Alarm Capacity:
    1000 messages
  • Recipe Capacity:
    5 recipes; 20 records each
  • Engineering Software:
    WinCC flexible Compact 2004 SP1 or higher
  • Weight:
    2.178 lbs (0.988 kg)
  • Estimated shipping dimensions:
    25.3x19.5x9.1cm
  • Tariff Code:
    85371098
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Display & Touch MPI & DP Project Resources Panel Mounting

Features:

  • The 5.7-inch blue-mode display presents configured process values, alarms, and operator controls.
  • Analog-resistive touch input replaces dedicated function keys with project-defined screen objects.
  • MPI and PROFIBUS DP exchange HMI tags and operator commands with supported SIMATIC controllers.
Siemens 6AV6642-0AA11-0AX1 turns controller data into configured screens and returns touch selections as project variables.

Flash storage in 6AV6642-0AA11-0AX1 retains the runtime project and recipe data without a removable card.

The installed front of 6AV6642-0AA11-0AX1 seals the operator side while the rear remains inside the cabinet.

The Siemens 6AV6642-0AA11-0AX1 SIMATIC TP 177A 5.7-Inch Touch Panel may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6AV6642-0AA11-0AX1 SIMATIC TP 177A 5.7-Inch Touch Panel Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Operator Screen and Input Surface

  • Display mode: The STN panel renders two blue levels at 320 x 240 pixels.
  • Touch layer: The analog-resistive surface converts pressure at a screen position into the configured operator action.
  • Screen objects: Text, I/O fields, bars, diagrams, graphics, and lists are placed by the HMI project.
  • Service tools: Touch calibration and clean-screen functions support alignment and maintenance.

Controller and Transfer Connections

  • RS485 path: The panel communicates with supported SIMATIC controllers through MPI or PROFIBUS DP.
  • Serial interface: The additional RS422 connection supports the documented service configuration.
  • Project transfer: Runtime data can be downloaded through MPI, PROFIBUS DP, or the serial route.
  • Data-rate limit: The RS485 connection operates up to 1.5 Mbit/s.

Screens, Alarms and Recipes

  • Process variables: Up to 500 configured variables connect screen objects with controller data.
  • Alarm handling: The project can contain 1000 messages with acknowledgment groups and process values.
  • Recipe storage: Five recipes use integrated flash for up to 20 records with 20 entries each.
  • Language selection: Five runtime languages can be selected from as many as 32 project languages.

Front Seal and Cabinet Side

  • Front boundary: The installed operator front reaches IP65 and NEMA 4X protection.
  • Rear boundary: The electronics behind the cutout remain IP20 and require enclosure protection.
  • Inclination limit: A vertical installation may incline up to 35 degrees without external ventilation.
  • Temperature range: The panel operates from 0 to 50 °C and stores or transports from -20 to 60 °C.
Description
Siemens 6AV6642-0AA11-0AX1 is a SIMATIC TP 177A operator panel for machine and process visualization. Its 5.7-inch blue-mode STN display and analog-resistive touch surface present configured values, alarms, recipes, and operator controls at the equipment interface.

Process data reaches 6AV6642-0AA11-0AX1 through its RS485-based MPI or PROFIBUS DP connection. The configured controller connection supplies tags and messages to the panel, while touch entries return operator commands and setpoints through the same project-defined path.

Projects for 6AV6642-0AA11-0AX1 are created with the supported WinCC flexible environment and transferred through MPI, PROFIBUS DP, or the serial service route. Integrated flash stores the runtime project, recipe records, and user data, but the software clock has no battery-backed retention.

Panel-mount installation places the IP65/NEMA 4X front of 6AV6642-0AA11-0AX1 outside the enclosure and leaves the IP20 rear within the cabinet. The permitted inclination and operating temperature therefore apply to the installed orientation rather than to the detached front alone.
Alternative Names
6AV66420AA110AX1 6AV6642 0AA11 0AX1 6AV 6642 0AA11 0AX1 Siemens 6AV6642-0AA11-0AX1 6AV6642-0AA11-0AX1 TP 177A Touch Panel 6AV6642-OAA11-0AX1 6AV6642-0AAII-0AX1 6AV6642-0AA11-OAXI
Technical notes
Siemens 6AV6642-0AA11-0AX1 combines a 5.7-inch resistive touch display, MPI/PROFIBUS DP communication, alarm handling, and recipe storage.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why can a new project fail to transfer to 6AV6642-0AA11-0AX1?
Confirm that 6AV6642-0AA11-0AX1 is selected as the target, the supported WinCC flexible version is used, and the chosen MPI/DP or serial path matches the panel settings.
Why does 6AV6642-0AA11-0AX1 display tags but not accept touch commands?
Recalibrate the 6AV6642-0AA11-0AX1 touch surface, check whether the object is enabled, and verify that its write tag and controller access permit changes.
What should be backed up before replacing 6AV6642-0AA11-0AX1?
Preserve the 6AV6642-0AA11-0AX1 WinCC flexible project, connection parameters, transfer settings, recipes, passwords, and any uploaded runtime data.
Why can alarms disappear after power loss on 6AV6642-0AA11-0AX1?
Siemens 6AV6642-0AA11-0AX1 uses a software clock without battery backup, so retained timestamps and history depend on the configured project and controller data.
Why can MPI communication work while PROFIBUS DP fails on 6AV6642-0AA11-0AX1?
The 6AV6642-0AA11-0AX1 bus address, baud rate, profile, cable termination, and controller connection must match the selected PROFIBUS DP project.
What must the enclosure provide behind 6AV6642-0AA11-0AX1?
Only the installed front of 6AV6642-0AA11-0AX1 is IP65/NEMA 4X; the IP20 rear requires cabinet protection, spacing, and ventilation.