For SIMATIC HMI systems, Siemens 6AV6545-0DA10-0AX0 is an MP 370 12-inch touch Multi Panel for visualization and operator input.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 6AV6545-0DA10-0AX0
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 6AV6545-0DA10-0AX0

  • Manufacturer:
    Siemens
  • Part Number:
    6AV6545-0DA10-0AX0
  • Product Family:
    Siemens Simatic HMI
  • Product Type:
    MP 370 12-inch Touch Multi Panel
  • Stock:
    1
  • Display:
    12.1-inch TFT
  • Resolution:
    800 × 600 pixels
  • Color Depth:
    256 colors
  • Touch Technology:
    Analog resistive
  • Processor:
    64-bit RISC
  • Operating System:
    Windows CE
  • User Flash:
    12 MB
  • WinCC Flexible Project Area:
    Up to 7 MB
  • Removable Storage:
    CompactFlash and PC Card slots
  • Controller Interfaces:
    MPI/PROFIBUS DP; RS232/TTY; RS422/485
  • Ethernet:
    10/100 Mbit/s
  • USB:
    1 host interface
  • Supply Voltage:
    24 V DC, −15%/+20%
  • Current Draw:
    0.6 A typical; 0.9 A maximum
  • Protection:
    IP65/NEMA 4X front; IP20 rear
  • Operating Temperature:
    0–50 °C vertical; 0–35 °C inclined
  • Weight:
    9.92 lbs (4.5 kg)
  • Tariff Code:
    8537101190
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Touch Control Data Storage Network Setup Installation

Features:

  • Twelve-inch touch operation presents an 800 × 600 HMI workspace.
  • Windows CE separates the panel runtime from controller execution.
  • Card slots support CompactFlash and PC Card removable media.
The analog-resistive touch surface provides the primary operator input method for this MP 370 version.

A 64-bit RISC platform runs the visualization project from internal flash memory.

Ethernet, fieldbus, serial and USB paths give the panel distinct roles for control and peripheral communication.

The Siemens 6AV6545-0DA10-0AX0 MP 370 12-inch Touch Multi Panel may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6AV6545-0DA10-0AX0 MP 370 12-inch Touch Multi Panel Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Operator-input behavior

  • Touch Surface: Analog-resistive sensing converts screen pressure into an input position.
  • Calibration: The runtime calibration aligns the physical touch point with the displayed target.
  • Screen Format: The project is composed for an 800 × 600 pixel workspace.
  • Color Presentation: The TFT panel renders the configured visualization in 256 colors.

Internal and removable data areas

  • Flash Area: Runtime project and user data use the internal 12 MB memory.
  • Project Limit: WinCC flexible configurations occupy up to 7 MB of the flash area.
  • CompactFlash: One slot accepts supported CompactFlash media.
  • PC Card: A separate slot provides the second removable-card format.

Controller-link selection

  • Ethernet: The 10/100 interface carries configured TCP/IP communication.
  • MPI/PROFIBUS: The fieldbus interface connects the panel to the selected SIMATIC network.
  • Serial Links: RS232/TTY and RS422/485 serve their configured peer connections.
  • USB Host: Supported peripherals use the host port rather than the PLC network path.

Mechanical and environmental limits

  • Panel Opening: The enclosure cutout must match the MP 370 touch-panel dimensions.
  • Front Seal: Correct clamping and gasket contact establish IP65/NEMA 4X front protection.
  • Rear Space: The IP20 rear area requires clearance for connectors and ventilation.
  • Mounting Angle: The permitted angle determines whether the 50 °C or 35 °C operating limit applies.
Description
The SIMATIC HMI MP 370 platform uses Siemens 6AV6545-0DA10-0AX0 as its 12.1-inch touch-operated Multi Panel. A 64-bit RISC processor and Windows CE runtime support graphical operator functions on an 800 × 600 TFT display.

Project and user data in 6AV6545-0DA10-0AX0 occupy a 12 MB flash area, with WinCC flexible configurations using up to 7 MB. CompactFlash and PC Card slots provide separate removable-media options for supported data and project operations.

Network selection on 6AV6545-0DA10-0AX0 can follow Ethernet 10/100, MPI/PROFIBUS DP or serial RS232/TTY and RS422/485 paths. The USB host connection is independent of these controller links and serves supported peripheral devices.

The front of 6AV6545-0DA10-0AX0 is designed for IP65/NEMA 4X protection when correctly mounted, while the rear is IP20. Its 24 V DC supply and permitted mounting angle must be considered together with the temperature limits of the installed enclosure.
Alternative Names
6AV65450DA100AX0 6AV 6545 0DA10 0AX0 6AV6545 0DA10 0AX0 Siemens 6AV6545-0DA10-0AX0 SIMATIC MP370 Touch 12 MP 370 12-inch Touch Panel 6AV654S-0DA10-0AX0 6AV6545-0DA1O-0AX0
Technical notes
Siemens 6AV6545-0DA10-0AX0 is an MP 370 touch HMI with Windows CE, removable-card storage and multiple controller interfaces.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What project details must match before loading Siemens 6AV6545-0DA10-0AX0?
Set Siemens 6AV6545-0DA10-0AX0 as the target MP 370 panel, then verify the engineering version, screen resolution and configured controller interface before transfer.
How can shifted touch points on Siemens 6AV6545-0DA10-0AX0 be corrected?
Run the touch calibration provided by Siemens 6AV6545-0DA10-0AX0 and complete each target point without changing the project communication settings.
Which storage medium should be prepared for Siemens 6AV6545-0DA10-0AX0?
Choose a supported CompactFlash or PC Card for Siemens 6AV6545-0DA10-0AX0 according to whether the task involves project data, backups or removable files.
Why can Siemens 6AV6545-0DA10-0AX0 reach Ethernet but not the PLC?
On Siemens 6AV6545-0DA10-0AX0, the Ethernet address, PLC connection object and subnet parameters must agree; a live link alone does not establish the configured controller session.
What enclosure checks are needed when installing Siemens 6AV6545-0DA10-0AX0?
Maintain the cutout, mounting angle, ventilation space and front sealing conditions required by Siemens 6AV6545-0DA10-0AX0 to preserve its environmental limits.
How should a USB device issue on Siemens 6AV6545-0DA10-0AX0 be isolated?
Verify that the peripheral is supported by the Windows CE USB host on Siemens 6AV6545-0DA10-0AX0 and is not being confused with a controller communication port.