Features:
- The PCI processor adds PROFINET controller and device functions to an industrial PC.
- Four 100 Mbit/s RJ45 ports form an integrated real-time Ethernet switch.
- ERTEC 400 hardware handles cyclic and isochronous communication outside the host CPU.
Siemens 6GK1161-6AA00 moves process data between host memory and the configured PROFINET network.
The integrated switch of 6GK1161-6AA00 connects four line or ring segments without a separate managed switch layer.
Engineering resources on 6GK1161-6AA00 define device counts, submodules, I/O volume, and real-time behavior.
The Siemens 6GK1161-6AA00 CP 1616 PROFINET PCI Communication Processor may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6GK1161-6AA00 CP 1616 PROFINET PCI Communication Processor Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Card Power and Host Exchange
- Bus format: The card installs in a compatible 32-bit PCI slot operating at 33 or 66 MHz.
- Voltage signaling: The host connector supports the documented 3.3 V and 5 V PCI signaling.
- Normal power: The PCI backplane supplies the communication processor during host operation.
- External feed: A 6 to 9 V DC connector supports the documented separate service or commissioning condition.
Controller and Device Operation
- Controller mode: The processor coordinates the configured group of PROFINET IO devices.
- Device mode: The same card can expose the documented I/O image as a PROFINET device.
- IRT capacity: Isochronous real-time operation is limited by the documented device and data resources.
- Engineering boundary: The selected role, station name, addresses, and I/O modules must agree with the project.
Real-Time Ethernet Forwarding
- Port group: Four RJ45 interfaces operate at 100 Mbit/s.
- Integrated forwarding: The card switches PROFINET frames between the connected segments.
- Management scope: The integrated switch is unmanaged rather than a standalone configurable Layer 2 switch.
- Ring participation: Configured ports can take the documented MRP client or redundancy-manager role.
Resource and Network Verification
- Topology discovery: LLDP exposes neighboring devices and port relationships to the engineering system.
- Device naming: DCP assigns and identifies the PROFINET station parameters.
- Status monitoring: SNMPv1 and Siemens diagnostics report supported processor and network conditions.
- Resource check: Device count, submodule count, and total I/O bytes are validated before commissioning.