Features:
- Combines a configurable mix of 16–24 inputs and 8–16 outputs.
- Provides a typical 0.3 ms digital-input response.
- Includes SYNIN and SYNOUT connections for IP257 synchronization.
The 4UA11 execution is defined by its mixed point allocation and synchronization interface. The installed split must be recorded rather than inferred from the family number.
One card can read machine states, drive selected 24 V loads and exchange timing signals with the IP257 application.
Preserve switch S2, the SYN wiring and the output-group current calculation. Test input bits and driven loads separately before enabling synchronized operation.
6ES5482-4UA11 is sourced with its actual mixed-I/O allocation and IP257 wiring documented.
Verified resources for Siemens 6ES5482-4UA11:
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Combine fast status acquisition and discrete actuation in a space-limited S5 rack.
- Coordinate machine events through the IP257 SYNIN/SYNOUT signal path.
- Maintain a legacy mixed-I/O station without changing its process-image organization.
- Represent the installed input/output split correctly in the S5 process-image assignment.
- Cross-reference every driven output and sensed input before moving the 42-pin connector.
- Keep synchronized logic associated with the IP257 separate from ordinary cyclic I/O tests.
- Use SYNIN and SYNOUT only with the documented IP257 synchronization arrangement.
- Set switch S2 to the position required by the established application.
- Match the 4UA11 field and timing interface rather than substituting another 482 variant.
- One front connection carries the mixed 24 V input, output and reference conductors.
- Output wiring is organized in groups of eight with a 4 A total allowance per group.
- The common fault path and red indication should remain traceable in the panel drawings.