Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Discontinued / Obsolete by OEM
    Apter Power provides documentation, quotations, and model verification for 6ES7412-2XG04-0AB0.

6ES7412-2XG04-0AB0

/ 4.9
1001 reviews | Need a Specific Revision?
Control logic, S7-400 rack I/O and PROFIBUS DP stations are coordinated by Siemens 6ES7412-2XG04-0AB0, a SIMATIC CPU 412-2 central processor.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 6ES7412-2XG04-0AB0
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 6ES7412-2XG04-0AB0

  • Manufacturer:
    Siemens
  • Part Number:
    6ES7412-2XG04-0AB0
  • Product Family:
    Siemens Simatic S7-400
  • Product Type:
    SIMATIC S7-400 CPU 412-2 Central Processor
  • Stock:
    1
  • Total Work Memory:
    256 KB
  • Program Memory:
    128 KB
  • Data Memory:
    128 KB
  • Expandable FEPROM:
    Up to 64 MB
  • Expandable RAM:
    Up to 16 MB
  • Process Image Inputs:
    Default 128 bytes; adjustable up to 4 KB
  • Process Image Outputs:
    Default 128 bytes; adjustable up to 4 KB
  • I/O Address Area:
    4 KB
  • First Interface:
    MPI/PROFIBUS DP up to 12 Mbit/s
  • Second Interface:
    Isolated PROFIBUS DP up to 12 Mbit/s
  • Maximum DP Slaves:
    64
  • DP Data per Slave:
    Up to 244 bytes input and 244 bytes output
  • Backplane Current at 5 V DC:
    Typically 1 A
  • Maximum Backplane Current:
    1.2 A
  • Power Loss:
    4.5 W
  • Firmware Version:
    V4.0
  • Weight:
    1.5873 lbs (0.72 kg)
  • Estimated shipping dimensions:
    2.5x29x21.9cm
  • Tariff Code:
    85371091
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Memory Layout MPI and DP Process Images Rack Operation

Features:

  • A 256 KB work-memory resource is divided equally between program and data.
  • The first interface supports MPI or PROFIBUS DP at rates up to 12 Mbit/s.
  • An isolated second PROFIBUS DP interface supplies a separate distributed-I/O path.
The CPU 412-2 controls S7-400 rack modules and distributed stations from one cyclic program.

Adjustable process images relate cyclic input and output data to the configured peripheral address space.

Backplane power, rack communication and diagnostic records remain tied to the installed S7-400 assembly.

The Siemens 6ES7412-2XG04-0AB0 SIMATIC S7-400 CPU 412-2 may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6ES7412-2XG04-0AB0 SIMATIC S7-400 CPU 412-2 Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Separating executable code from runtime data

  • Program section: One half of the work memory contains executable blocks and program structures.
  • Data section: The other half holds data blocks and runtime values used by the program.
  • Load memory: A compatible memory card expands nonvolatile storage for the project.
  • Retention: Battery-backed areas preserve configured values when the rack supply is interrupted.

Assigning the two integrated communication paths

  • First interface: MPI or PROFIBUS DP can connect engineering, operator or distributed stations.
  • Second interface: The isolated PROFIBUS DP port provides a separate fieldbus connection.
  • Bus speed: Each documented PROFIBUS route operates up to 12 Mbit/s.
  • DP stations: The second interface can coordinate the documented number of distributed slaves.

Moving cyclic I/O data through the CPU

  • Input image: Module input states are copied into the process image before program processing.
  • Program access: Logic reads the stored input image and calculates output results.
  • Output image: Calculated states remain in the output image until transfer to the modules.
  • Adjustable size: The image ranges can be expanded to match the configured cyclic address requirement.

Relating backplane resources to CPU status

  • Power source: The CPU receives 5 V DC operating power from the S7-400 backplane.
  • Module exchange: Rack buses carry data between the processor and installed modules.
  • Diagnostic buffer: Recorded events identify processor, module and communication conditions.
  • Front indicators: Status LEDs distinguish operating mode, faults and communication activity.
Description
Siemens 6ES7412-2XG04-0AB0 is the SIMATIC S7-400 CPU 412-2 central processor. It executes the user program, exchanges process data with rack modules and coordinates distributed stations through its integrated communication interfaces.

Working storage in 6ES7412-2XG04-0AB0 is divided between program and data memory, so executable blocks and runtime values occupy defined parts of the same CPU resource. Load-memory cards extend the nonvolatile program store, while battery-backed areas preserve configured data when rack power is removed.

The first interface on 6ES7412-2XG04-0AB0 can serve MPI or PROFIBUS DP communication for engineering, operator access or distributed I/O. Its isolated second PROFIBUS DP interface provides another bus path, allowing field stations to be separated from the programming and peer-communication route.

Process images inside 6ES7412-2XG04-0AB0 collect input states before the program cycle and hold output results until they are transferred to the modules. Their adjustable size relates the cyclic data area to the configured I/O address space rather than forcing every peripheral address into the default image.

Installed in the S7-400 rack, 6ES7412-2XG04-0AB0 takes its operating power from the 5 V backplane and communicates with adjacent modules over the rack buses. Diagnostic buffers and status indicators record processor, communication and module events so a bus fault can be separated from a program stop.
Alternative Names
6ES74122XG040AB0 6ES7 412-2XG04-0AB0 6ES7412 2XG04 0AB0 Siemens 6ES7412-2XG04-0AB0 CPU 412-2 6ES7412-2XG04-0AB0 S7-400 6ES7412-2XG04-0AB0 6ES7412-2XGO4-0AB0 6ES74I2-2XG04-0AB0
Technical notes
Siemens 6ES7412-2XG04-0AB0 divides 256 KB of work memory equally between program and data. Its second communication interface is an isolated PROFIBUS DP master/slave port.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How is work memory divided in 6ES7412-2XG04-0AB0?
The 256 KB work memory of 6ES7412-2XG04-0AB0 assigns 128 KB to program code and 128 KB to data.
Why does 6ES7412-2XG04-0AB0 have two communication interfaces?
The first 6ES7412-2XG04-0AB0 interface can handle MPI or DP, while the isolated second interface provides a separate PROFIBUS DP path.
Can 6ES7412-2XG04-0AB0 expand its nonvolatile program storage?
A compatible FEPROM memory card expands the load memory used by 6ES7412-2XG04-0AB0.
What happens before the user program reads inputs on 6ES7412-2XG04-0AB0?
The 6ES7412-2XG04-0AB0 copies configured module states into its input process image before cyclic logic uses them.
Where does 6ES7412-2XG04-0AB0 receive operating power?
The 6ES7412-2XG04-0AB0 receives 5 V DC from the SIMATIC S7-400 rack backplane.
How can a technician separate a bus fault from a CPU stop on 6ES7412-2XG04-0AB0?
Check the status indicators and diagnostic buffer of 6ES7412-2XG04-0AB0 for processor, module and communication events.