GSI127 244-127-000-017-A2-B01
GSI127 244-127-000-017-A2-B01
GSI127 244-127-000-017-A2-B01
GSI127 244-127-000-017-A2-B01
GSI127 244-127-000-017-A2-B01
GSI127 244-127-000-017-A2-B01
Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Discontinued / Obsolete by OEM
    Apter Power reviews exact suffix, approvals, condition, documentation, and replacement evidence.

GSI127 244-127-000-017-A2-B01

/ 4.9
1001 reviews | Need a Specific Revision?
Vibro-Meter GSI127 244-127-000-017-A2-B01 is a galvanic separation unit configured for explosive-environment use and CExxx current-output sensors.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for GSI127 244-127-000-017-A2-B01
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for GSI127 244-127-000-017-A2-B01

  • Manufacturer:
    Vibro-Meter
  • Part Number:
    GSI127 244-127-000-017-A2-B01
  • Product Family:
    GSI127 Galvanic Separation Units
  • Product Type:
    Galvanic Separation Unit for Current-Output Sensors
  • Stock:
    1
  • Manufacturer part number:
    244-127-000-017
  • Configuration:
    A2-B01
  • A2 meaning:
    Explosive-environment configuration
  • B01 transfer:
    1 V/mA
  • B01 reference point:
    5 mA input to 7 V output
  • Sensor family:
    CExxx current-output sensors
  • Module function:
    Galvanic separation
  • Published successor family:
    244-127-000-021
  • Weight:
    0.15 kg
  • Estimated shipping dimensions:
    2.2x11.5x11.8cm
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    Switzerland
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Signal Transfer Hazardous Area Service Boundary Product Applications

Features:

  • Galvanic separation: isolates the current-output sensor path from monitoring electronics
  • A2 configuration: the suffix identifies the documented explosive-environment version
  • B01 transfer: official data assigns the 1 V/mA response for CExxx current sensors
Vibro-Meter GSI127 244-127-000-017-A2-B01 is a precisely coded sensor-interface unit rather than a generic GSI127 variant.

The suffix links hazardous-area configuration and transfer behaviour to the connected CExxx current-output measurement chain.

Selection must retain the complete code, approvals, sensor family, supply, grounding, wiring, transfer check, and obsolete-family replacement boundary.

Apter Power supports document review, quotation, and procurement for the Vibro-Meter GSI127 244-127-000-017-A2-B01 Galvanic Separation Unit for Current-Output Sensors.
Vibro-Meter GSI127 244-127-000-017-A2-B01 Galvanic Separation Unit for Current-Output Sensors Manuals,Datasheets,Link
Important Notice: No qualified exact-model English PDF is attached. Use the complete product model in every document request.
  • Current input: the B01 variant is paired with CExxx current-output sensors.
  • Voltage output: the documented transfer is 1 V for each milliampere.
  • Reference point: official data shows 5 mA input corresponding to 7 V output.
  • Configuration stop: another B suffix must not be assumed to provide the same behaviour.
  • A2 identity: the configuration belongs to the documented explosive-environment version.
  • Approval record: certificate and installation conditions must match the site classification.
  • Grounding path: separation, shield, and earth arrangements follow the approved system drawing.
  • Work control: isolation and inspection requirements remain part of the hazardous-area procedure.
  • Older family: 244-127-000-017 is identified in the manufacturer replacement notice.
  • Published successor: the notice points to the 244-127-000-021 family.
  • No automatic equivalence: suffix, approvals, transfer, and wiring still require engineering review.
  • Commissioning proof: inject the approved current and confirm the expected voltage and monitoring value.
  • Vibration sensor isolation: separate CExxx current signals from monitoring electronics.
  • Hazardous-area measurement: maintain the approved A2 interface configuration.
  • Legacy spare service: replace the exact B01 transfer variant without suffix drift.
  • Migration review: evaluate the published successor against approvals, wiring, and channel behaviour.
Description
Between a current-output vibration sensor and downstream monitoring electronics, GSI127 244-127-000-017-A2-B01 provides the documented galvanic separation boundary. Its A2 code identifies the explosive-environment configuration, while B01 identifies the 1 V/mA transfer used with CExxx current-output sensors.

The conversion detail matters when GSI127 244-127-000-017-A2-B01 is compared with nearby B02 or other GSI127 variants. Official documentation associates B01 with a 5 mA input producing a 7 V output, so suffix agreement, field wiring, supply, grounding, and connected sensor type must precede any functional test.

Meggitt published a replacement path from the older 244-127-000-017 family to 244-127-000-021, but that notice does not make GSI127 244-127-000-017-A2-B01 automatically interchangeable. A migration decision still needs hazardous-area review, transfer behaviour, terminal mapping, approvals, and the monitoring-system acceptance procedure.
Alternative Names
Vibro Meter GSI127 A2 B01 Vibro-Meter 244127000017 A2 B01 GSI 127 244-127-000-017 A2-B01 GSI127 244127000017A2B01 Meggitt GSI127 A2-B01 GSI127 galvanic separation unit B01 244-127-000-017-A2-B01 module GSI127 current output separator GSI127 A2B01
Technical notes
For GSI127 244-127-000-017-A2-B01 service, preserve the complete A2-B01 suffix, CExxx sensor identity, supply, terminal map, grounding, hazardous-area documentation, input current, output voltage, and monitoring-channel configuration. Do not substitute a B02 or newer 244-127-000-021 unit solely from family name; verify transfer behaviour, approvals, and wiring before commissioning.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What does B01 mean in GSI127 244-127-000-017-A2-B01?
Official Vibro-Meter data identifies B01 as the 1 V/mA configuration for CExxx current-output sensors, including a documented 5 mA to 7 V reference point.
Can GSI127 244-127-000-017-A2-B01 be replaced by a B02 variant?
Not without qualified engineering evidence. The suffix defines transfer behaviour and sensor pairing, so family similarity alone cannot establish electrical or functional equivalence.
What does A2 indicate for GSI127 244-127-000-017-A2-B01?
A2 identifies the documented explosive-environment configuration, making certificate, installation-condition, grounding, and site-classification review part of the selection.
How should GSI127 244-127-000-017-A2-B01 be functionally checked?
With the channel safely isolated, apply an approved current stimulus, confirm the expected voltage transfer, then verify the downstream monitoring value and diagnostics.
Is 244-127-000-021 an automatic replacement for GSI127 244-127-000-017-A2-B01?
No. The manufacturer publishes a successor family, but the exact suffix, transfer, approvals, terminals, wiring, and system acceptance still require comparison.
What should accompany a request for GSI127 244-127-000-017-A2-B01?
Provide the full configuration, sensor model, hazardous-area classification, wiring and grounding record, supply, required condition, quantity, destination, and outage timing.