S3960 GSI127 244-127-000-017 A1-B02

/ 4.9
1001 reviews | Need a Specific Revision?
Vibro-Meter 244-127-000-017 A1-B02 is a standard-area GSI127 galvanic separation unit with 1 V/mA conversion. It isolates a current-output measurement chain from the monitoring system.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for S3960 GSI127 244-127-000-017 A1-B02
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for S3960 GSI127 244-127-000-017 A1-B02

  • Manufacturer:
    Vibro-Meter
  • Part Number:
    S3960 GSI127 244-127-000-017 A1-B02
  • Product Family:
    GSI127 Galvanic Separation Units
  • Product Type:
    GSI127 Galvanic Separation Unit
  • Stock:
    1
  • Product function:
    Galvanic separation and signal conversion
  • Environment code:
    A1, standard area
  • Transfer option:
    B02
  • Transfer sensitivity:
    1 V/mA
  • Output offset:
    -5 VDC
  • Nominal conversion without diagnostics:
    12 mA input to 7 V output
  • Nominal conversion with diagnostics:
    13 mA input to 8 V output
  • Compatible input equipment:
    IPCxxx or VE210 with current output
  • Sensor-side supply:
    20 VDC ±1 VDC, 21 to 30 mA
  • Input dynamic range:
    2 to 20.75 mA
  • Output dynamic range:
    0.8 to 20.8 VDC with 10 kΩ load
  • Output impedance:
    Below 30 Ω, short-circuit protected
  • Input supply:
    24 VDC nominal, 20 to 28 VDC
  • Power consumption:
    Below 3.1 W
  • Current consumption:
    Below 130 mA at 24 VDC
  • Sensor-to-monitor isolation:
    4 kVRMS
  • Supply-to-output isolation:
    50 VRMS
  • DC transfer accuracy:
    ±1% at ambient temperature
  • Linearity error:
    Below 0.2% best straight-line INL
  • Weight:
    0.31 lbs (0.14 kg)
  • Estimated shipping dimensions:
    11.4 × 4.1 × 11.7 cm
  • Tariff Code:
    8537101190
  • Country of origin:
    Switzerland
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Applications Galvanic Isolation Safety Certifications

Features:

  • Provides galvanic separation for compatible Vibro-Meter signal and control circuits.
  • Preserves circuit isolation between the protected system and connected field-side equipment.
  • Uses the complete S3960 GSI127 244-127-000-017 A1-B02 ordering identity.
The selected configuration is the GSI127 galvanic separation unit identified by the A1-B02 suffix.

It separates connected circuits so measurement or control information can pass without a direct conductive reference.

Confirm signal direction, supply, terminal assignment, approvals and suffix before replacing the installed unit.

Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Vibro-Meter 244-127-000-017 A1-B02: Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Separates compatible monitoring circuits where different ground references must be maintained.
  • Supports machinery-protection wiring that requires a defined isolation boundary.
  • Provides an exact-suffix replacement for installed A1-B02 galvanic separation assemblies.
  • Electrical separation prevents a direct conductive path between the connected circuit sides.
  • Terminal groups must remain on their assigned input and output sides to preserve the isolation boundary.
  • Insulation integrity should be checked whenever wiring or enclosure work affects the module.
  • De-energize connected circuits and prove the absence of voltage before disturbing terminal wiring.
  • Maintain creepage, clearance and protective-earth arrangements specified for the cabinet installation.
  • Do not bypass the isolation path during testing or temporary commissioning.
  • Apply only the approvals documented for the complete A1-B02 order configuration.
  • Installation conditions associated with any safety or hazardous-area approval must be retained.
  • Use the product label and project certification schedule when confirming a replacement.
Description
Vibro-Meter 244-127-000-017 A1-B02 is a GSI127 galvanic separation unit for standard industrial environments. The B02 option converts the documented current-input measurement chain to a voltage signal while maintaining electrical separation between the sensor side and monitor side. The standard-area A1 construction and B02 transfer option must be considered together because the same GSI127 family supports several different signal types and installation classes.

The module can interface current-output IPCxxx or VE210 measurement equipment with compatible machinery-monitoring electronics. Its DC-to-20 kHz transfer bandwidth preserves both quasi-static and dynamic information while the low-impedance, short-circuit-protected output supports cabinet wiring to the receiving system. Galvanic isolation also limits frame-voltage influence between the measurement chain and monitor, which is valuable where long cable routes or dissimilar grounding points would otherwise affect the signal.

DIN-rail mounting and removable screw terminals simplify controlled replacement, but the environment and sensitivity codes remain essential. The power supply, input standing current, output scaling, shield termination and isolation arrangement should be verified before reconnecting a protection channel. After wiring, compare the expected standing current with the observed monitor voltage before enabling the channel; this simple check confirms both conversion offset and loop continuity.
Alternative Names
244-127-000-017 A1-B02 244127000017A1B02 244 127 000 017 A1 B02 GSI127 A1-B02 Vibro-Meter 244-127-000-017 GSI127 1 V/mA Galvanic Separation Unit 244-127-000-017 GSI127 Standard Version GSI127 B02 Current-to-Voltage Interface
Technical notes
Before replacing 244-127-000-017 A1-B02, confirm the standing current and B02 transfer function; the wrong transfer code changes the monitor voltage.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What does S3960 GSI127 244-127-000-017 A1-B02 convert?
It converts the documented current signal to a voltage output using the B02 1 V/mA transfer function.
Which measurement chains suit S3960 GSI127 244-127-000-017 A1-B02?
It supports IPCxxx or VE210 equipment using the specified current-output transmission arrangement.
Is S3960 GSI127 244-127-000-017 A1-B02 intended for hazardous areas?
No. Code A1 identifies the standard-area GSI127 configuration.
Can S3960 GSI127 244-127-000-017 A1-B02 be replaced by another GSI127 configuration?
No. Match the environment and transfer codes because they determine isolation use, conversion and zero shift.
Which manual covers S3960 GSI127 244-127-000-017 A1-B02?
Use the official GSI127 data sheet and the applicable measurement-chain installation manual.
What details are needed to quote S3960 GSI127 244-127-000-017 A1-B02?
Provide the full A1-B02 code, connected conditioner, input standing current, quantity and destination.