Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Discontinued / Obsolete by OEM
    Apter Power supports IPC707 legacy sourcing, code checks and documentation.

IPC707 244-707-000-012 A1-B1-C9810-D3-E5-F2000-G2

/ 4.9
1001 reviews | Need a Specific Revision?
Vibro-Meter 244-707-000-012 A1-B1-C9810-D3-E5-F2000-G2 is an IPC707 signal conditioner for piezoelectric vibration chains. Its integrated conversion and filters deliver a current velocity output.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for IPC707 244-707-000-012 A1-B1-C9810-D3-E5-F2000-G2
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IPC707 244-707-000-012 A1-B1-C9810-D3-E5-F2000-G2

  • Manufacturer:
    Vibro-Meter
  • Part Number:
    IPC707 244-707-000-012 A1-B1-C9810-D3-E5-F2000-G2
  • Product Family:
    IPC707 Signal Conditioners
  • Product Type:
    Signal Conditioner
  • Stock:
    1
  • Product function:
    Piezoelectric sensor signal conditioner
  • Environment code:
    A1, standard area
  • Diagnostics code:
    B1, without diagnostics
  • Transfer sensitivity code:
    C9810
  • Transfer sensitivity:
    9,810 µA/pC·s
  • Transfer units code:
    D3, with integrator
  • Output measurement:
    Velocity
  • Signal transmission:
    Current output, 2-wire
  • High-pass filter:
    E5, 5 Hz
  • Low-pass filter:
    F2000, 2,000 Hz
  • Installation code:
    G2, with DIN-rail adapter
  • Frequency capability:
    0.5 Hz to 20 kHz, configuration dependent
  • Supply voltage:
    18 to 30 VDC
  • Current consumption:
    20 mA nominal
  • Transfer accuracy:
    ±3% maximum
  • Linearity error:
    Below 0.2%
  • Input dynamic range:
    Up to 50,000 pC below 10 kHz
  • Output dynamic signal:
    ±5 mA peak maximum
  • Operating and storage temperature:
    -40 to 85°C
  • Weight:
    0.39 lbs (0.175 kg)
  • Estimated shipping dimensions:
    7.94 × 5.4 × 4.5 cm
  • Tariff Code:
    8537101190
  • Country of origin:
    Switzerland
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Applications Configuration Performance Protection

Features:

  • Converts the documented input supply into the regulated power required by compatible monitoring hardware.
  • Provides a dedicated IPC707 power-interface function within the approved Vibro-Meter arrangement.
  • Uses order number 244-707-000-012 to distinguish the exact converter configuration.
The selected item is the IPC707 converter identified by its complete order number.

It supports the power path used by compatible monitoring equipment without replacing signal-processing functions.

Confirm input range, output requirements, terminal polarity, protection and enclosure cooling before installation.

Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Vibro-Meter 244-707-000-012: Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Supplies compatible monitoring and protection circuits from the specified cabinet power source.
  • Provides a model-specific replacement in machinery-monitoring panels using the IPC707 converter.
  • Supports controlled maintenance of the power interface without altering measurement-channel configuration.
  • Input supply and output connection must match the documented IPC707 terminal arrangement.
  • Polarity, protective devices and conductor sizing should be verified against the existing cabinet drawings.
  • Do not transfer field wiring until the exact 244-707-000-012 configuration is confirmed.
  • Regulated output supports stable operation of the connected monitoring electronics.
  • Power loading must remain within the documented converter capacity under normal and startup conditions.
  • Voltage should be checked at the load after installation to account for conductor drop and cabinet wiring.
  • Input and output circuits should retain the protective devices specified for the installed converter arrangement.
  • Correct polarity and conductor sizing reduce the risk of damaging the converter or connected monitoring electronics.
  • Investigate repeated protection operation before fitting a replacement unit or restoring power.
Description
Vibro-Meter 244-707-000-012 A1-B1-C9810-D3-E5-F2000-G2 is a factory-configured IPC707 for piezoelectric vibration measurement in a standard industrial area. Its C9810 and D3 options combine a 9,810 µA/pC·s transfer sensitivity with integration to create a current-output velocity signal. The complete sequence is essential because the base IPC707 number alone does not identify its diagnostics, conversion, filter limits or mounting hardware.

The conditioner powers and processes a compatible charge-output sensor while the 5 Hz high-pass and 2,000 Hz low-pass selections define the useful signal band. A two-wire output carries the conditioned measurement to suitable monitoring electronics, with the optional G2 adapter supporting DIN-rail cabinet installation. Integration converts acceleration-related charge into a velocity-proportional signal, giving the receiving system a conditioned variable suited to the selected machinery-monitoring strategy.

Ordering option B1 identifies a version without the internal diagnostic function, so condition validation must be performed by the connected monitoring system and commissioning tests. Because the configuration is fixed during manufacture, every option code must be matched when replacing the unit. A controlled injection or vibration check should confirm the configured band and scale at the monitor input, since a correct physical installation can still produce an incorrect engineering value.
Alternative Names
244-707-000-012 A1-B1-C9810-D3-E5-F2000-G2 244707000012A1B1C9810D3E5F2000G2 244 707 000 012 A1 B1 C9810 D3 E5 F2000 G2 IPC707 A1-B1-C9810-D3-E5-F2000-G2 Vibro-Meter 244-707-000-012 IPC707 9810 µA/pC·s Velocity Conditioner 244-707-000-012 IPC707 DIN-Rail Version IPC707 B1 No-Diagnostics Signal Conditioner
Technical notes
Before installing 244-707-000-012 A1-B1-C9810-D3-E5-F2000-G2, verify the sensor charge sensitivity and fixed C/D/E/F codes; this B1 version cannot report chain faults.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What output does IPC707 244-707-000-012 A1-B1-C9810-D3-E5-F2000-G2 produce?
C9810 with D3 produces an integrated current-output velocity signal at 9,810 µA/pC·s.
What measurement does 244-707-000-012 A1-B1-C9810-D3-E5-F2000-G2 provide?
Its D3 integrator converts acceleration-related charge signals into a velocity-related current output. Final sensitivity depends on the connected sensor.
Which filter band is configured for IPC707 244-707-000-012 A1-B1-C9810-D3-E5-F2000-G2?
The E5 and F2000 options set 5 Hz high-pass and 2,000 Hz low-pass filtering.
Is 244-707-000-012 A1-B1-C9810-D3-E5-F2000-G2 suitable for hazardous-area or SIL applications?
No. A1 is the standard non-Ex version, and B1 does not include diagnostics. Hazardous-area versions require A2 or A3, while SIL-related applications require the B2 diagnostic configuration.
Can IPC707 244-707-000-012 A1-B1-C9810-D3-E5-F2000-G2 be replaced by another configuration?
Only after every A-to-G option is matched; the factory-set transfer, filtering and diagnostics cannot be changed later.
What details support an IPC707 244-707-000-012 A1-B1-C9810-D3-E5-F2000-G2 quote?
Provide the full option code, connected sensor and charge sensitivity, required quantity and destination.