Features:
- Channel capacity: Provides 64 single-ended, 64 pseudo-differential or 32 differential inputs.
- Conversion: Performs 16-bit analog-to-digital conversion.
- Acquisition flexibility: Supports triggered, scanned and direct channel modes with programmable gain.
Choose the input topology and voltage range before wiring field signals.
Match the address, interrupt and conversion-format settings to the host software.
Retain the original gain-range jumpers and per-channel gain values when replacing an installed module.
Apter Power supports Xycom XVME-564 VMEbus Analog Input Module quotations, technical documents and installed-configuration matching.
Xycom XVME-564 VMEbus Analog Input Module Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Topology: Choose single-ended for dense common-reference wiring, pseudo-differential for separate returns, or differential for common-mode rejection; channel capacity changes with the choice.
- Voltage range: Use the smallest range that contains every expected signal; an undersized range clips peaks, while an oversized range reduces usable resolution.
- Data format: Choose straight-binary or two’s-complement conversion to match the host software.
- Gain range: Set the hardware gain range before assigning per-channel software gain.
- Single channel: Reserve the 100 kHz mode for one high-rate input; multi-channel scanning trades per-channel update rate for coverage.
- Autoscanning: Choose 8, 16, 32 or 64 channels to balance coverage against the required scan interval.
- External trigger: Use an external trigger when acquisition must align with another machine event.
- Channel sequencing: Use random sequencing for selected points or sequential operation for contiguous channel groups.
- Host requirement: Use a host processor and controller subsystem in the same VMEbus backplane.
- Bus transfer: The module operates as an A24/A16 D16 data-transfer-bus slave.
- Interrupt level: Select one VMEbus interrupt level or disable module interrupts with SW-2.
- Failure output: Choose whether the red fail indication is allowed to assert SYSFAIL.
- Temperature sensing: Supports RTDs, thermistors and temperature transmitters.
- Force measurement: Supports strain-gauge and load-cell signal acquisition.
- Motion feedback: Supports tach generators and slide-wire inputs.
- Laboratory signals: Supports microphones and analytical equipment.