Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for ASR133-S00

  • Manufacturer:
    Yokogawa
  • Part Number:
    ASR133-S00
  • Product Family:
    Centum CS-Centum VP
  • Product Type:
    RTD/POT Input Module with Built-In Barrier
  • Stock:
    1
  • Input Channels:
    8 isolated
  • RTD Wiring:
    2-, 3-, or 4-wire
  • RTD Types:
    Pt50/100/200/500/1000; Ni100/120/200
  • POT Input:
    3-wire, 0–10 kΩ
  • Measurement Current:
    150 µA
  • Update Period:
    1 s maximum
  • Terminal Block:
    ATSR3□
  • Operating Temperature:
    -20 to 70 °C
  • Weight:
    0.661 lbs (0.3 kg)
  • Estimated shipping dimensions:
    3.28 × 10.75 × 13.0 cm
  • Tariff Code:
    8537101190
  • Country of origin:
    Japan
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Input Options Measurement Installation

Features:

  • Eight Individually Isolated RTD/POT Input Channels
  • Supports Two-, Three-, and Four-Wire RTD Connections
  • Accepts Three-Wire Potentiometers from 0 to 10 kΩ
The Yokogawa ASR133-S00 acquires resistance-based temperature and potentiometer signals for FIO Field Control Units. Supported platinum and nickel RTDs can be selected by channel together with the documented wiring method.

For resistance measurement, the module accepts three-wire potentiometers across the specified 0 to 10 kΩ range. The built-in barrier provides galvanic separation between field and system interfaces.

Before ordering the Yokogawa ASR133-S00, confirm the complete suffix code, channel requirements, terminal block, and Field Control Unit configuration.

Yokogawa ASR133-S00 Manuals, Datasheets, Drivers, Link Important Notice: Manuals, accessories, cables, calibration data, and software are not included unless specifically listed in the quotation or product description. Please confirm documentation and accessory requirements before ordering.
Yokogawa ASR133-S00 RTD/POT Input Module with Built-In Barrier Specs

General

  • Manufacturer Yokogawa
  • Model ASR133-S00
  • Condition New Original ready stock
  • Product Family ASR133-S00, ASR133, FIO Built-In Barrier Modules
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Eight isolated input channels
  • RTD connection supports two-, three-, or four-wire methods
  • Supported Pt sensors: Pt50, Pt100, Pt200, Pt500, and Pt1000
  • Supported Ni sensors: Ni100, Ni120, and Ni200
  • Three-wire potentiometer input range: 0 to 10 kΩ
  • Measurement current: 150 µA
  • Update period: 1 second maximum
  • Burnout direction can be configured
  • Specified for Zone 2 or Division 2 installation
  • Pressure clamp terminal connection through ATSR3□
  • Operating ambient temperature: -20 to 70 °C
  • Approximate module dimensions: 32.8 × 107.5 × 130 mm
Description
The Yokogawa ASR133-S00 is an eight-channel RTD/POT input module with a built-in barrier for CENTUM VP Field Control Units. It accepts supported resistance-temperature detectors and three-wire potentiometer inputs.

The module supports two-, three-, and four-wire RTD connections using documented platinum and nickel sensor types. Each channel can be selected individually, while potentiometer measurement covers 0 to 10 kΩ.

Galvanic isolation separates the field interface from the system, and the input channels are individually isolated. Yokogawa specifies Zone 2 or Division 2 installation under documented conditions.
Alternative Names
Yokogawa ASR133-S00 ASR133 S00 ASR133S00 Yokogawa ASR133 ASR133 RTD Input Module ASR133 POT Input Module CENTUM VP ASR133-S00
Technical notes
Yokogawa ASR133-S00 provides eight isolated RTD/POT input channels with selectable sensor type, wiring method, and burnout direction.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What is the Yokogawa ASR133-S00?
The ASR133-S00 is a rtd/pot input module with built-in barrier with eight isolated RTD or potentiometer input channels.
Which system is Yokogawa ASR133-S00 compatible with?
Yokogawa documents it for FIO Field Control Units, including AFV30S and AFV30D configurations.
What should be checked before replacing Yokogawa ASR133-S00?
Verify the complete order code, channel configuration, wiring, connector requirements, and controller compatibility before replacement.
What is the lifecycle status of Yokogawa ASR133-S00?
Yokogawa includes the model in current FIO documentation; availability is confirmed during quotation.
Is the Yokogawa ASR133-S00 manual available with a quotation?
Apter Power can provide relevant official technical documentation with the quotation when available.
How can I request price and availability for Yokogawa ASR133-S00?
Send the complete model, required quantity, destination, and any revision requirements to Apter Power for confirmation.
Which RTD wiring methods does Yokogawa ASR133-S00 support?
The module supports two-, three-, and four-wire RTD connections using the documented sensor types.