ARS15M-310

/ 4.9
1001 reviews | Need a Specific Revision?
Yokogawa ARS15M-310 is a DIN-rail 32-point solid-state relay input board for 10 to 30 V DC signals for CENTUM VP FIO Relay Boards.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for ARS15M-310
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for ARS15M-310

  • Manufacturer:
    Yokogawa
  • Part Number:
    ARS15M-310
  • Product Family:
    Centum CS-Centum VP
  • Product Type:
    Solid State Relay Board (32 Solid State Inputs)
  • Stock:
    1
  • Signal Service:
    Solid-state relay voltage input
  • Input Variant:
    10 to 30 V DC
  • Contact Points:
    32 points
  • Field Terminals:
    Pressure clamp
  • Connectable Modules:
    ADV151 with ATD5A; ADV161
  • Signal Cables:
    AKB331 for 32-point; AKB337 for 64-point
  • Ordering Code:
    -3 DC input; 1 DIN rail mountable; 0 basic type
  • ON Signal:
    10 to 30 V DC
  • OFF Signal:
    1 V DC or less
  • Internal Circuit Supply:
    24 V DC, maximum 1.0 A
  • Insulation Resistance:
    At least 10 megohm at 500 V DC
  • Withstanding Voltage:
    2.3 kV AC for 1 minute between power and field terminals
  • Ambient Temperature:
    0 to 50 C
  • Relative Humidity:
    10 to 90% RH
  • Other Official Variants:
    ARS15M-110: 100 V AC; ARS15M-210: 220 V AC
  • Weight:
    3 kg
  • Estimated shipping dimensions:
    43.6 x 12.54 x 9.8 cm
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    Japan
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Input Range Terminal Wiring Variant Review

Features:

  • DC input variant: The -310 code identifies 10 to 30 V DC input service.
  • Pressure-clamp field wiring: Thirty-two input points use the official clamp-terminal arrangement.
  • Documented redundant path: ADV161 uses two boards and two AKB337 cables in the stated configuration.

ARS15M-310 is the DC-input member of the Yokogawa ARS15M solid-state relay board family.

The -110 and -210 variants use different AC input ranges and should not be treated as equivalent to the -310 configuration.

Before purchase, check the installed suffix, signal voltage, pressure-clamp wiring, module path, and internal 24 V DC supply.

Availability is subject to Apter Power's current inventory and sourcing confirmation.

Yokogawa ARS15M-310 Solid State Relay Board (32 Solid State Inputs) Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Yokogawa ARS15M-310 Solid State Relay Board (32 Solid State Inputs) Specs

General

  • ManufacturerYokogawa
  • ModelARS15M-310
  • ConditionNew and factory sealed
  • Product FamilyCENTUM VP FIO Relay Boards

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

DC signal verification

  • ON signal: Confirm 10 to 30 V DC.
  • OFF signal: Confirm 1 V DC or less.
  • Signal polarity: Follow the official terminal A/B assignment.
  • Commissioning: Test each point against the documented thresholds.

Pressure-clamp preparation

  • Point count: Retain the 32-point input schedule.
  • Terminal method: Use the official pressure-clamp preparation.
  • Internal supply: Provide 24 V DC within the 1.0 A maximum.
  • Redundancy: Wire both documented paths when ADV161 redundancy is used.

ARS15M suffix comparison

  • ARS15M-110: Official 100 V AC input variant.
  • ARS15M-210: Official 220 V AC input variant.
  • ARS15M-310: Official 10 to 30 V DC input variant.
  • Ordering: Do not select the family from appearance alone.
Description

The Yokogawa ARS15M-310 is a DIN-rail 32-point solid-state relay input board for 10 to 30 V DC signals in the CENTUM VP FIO Relay Boards family.

Official documentation for ARS15M-310 confirms this configuration. Its -3 suffix defines the DC input module, while the remaining suffix positions define DIN-rail mounting and the basic type.

Before ordering ARS15M-310, verify the 10 to 30 V DC signal range, -310 suffix, pressure-clamp wiring, FIO module, and cable path.

Alternative Names
Yokogawa ARS15M-310 ARS15M-310 ARS15M ARS15M 310 ARS15M310 ARS15M-310 Solid State Relay Board (32 Solid State Inputs) ARS15M-310 CENTUM VP ARS15M CENTUM VP FIO Relay Boards
Technical notes
ARS15M-310 is a DIN-rail 32-point solid-state relay input board for 10 to 30 V DC signals. Confirm the complete suffix, connected hardware, and documented field interface before procurement.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What input signal does ARS15M-310 accept?
Yokogawa specifies 10 to 30 V DC for ON and 1 V DC or less for OFF.
How does ARS15M-310 differ from ARS15M-110 and ARS15M-210?
ARS15M-310 is the DC-input variant; -110 is 100 V AC and -210 is 220 V AC.
Which modules can connect to ARS15M-310?
The official specification lists ADV151 with ATD5A and ADV161, using the documented signal cable path.
How can buyers verify the correct ARS15M-310?
Check the complete -310 code, pressure-clamp terminals, DC signal range, module, cable, and nameplate.
Can ARS15M-110 directly replace ARS15M-310?
No direct replacement is claimed. Their official input voltage ranges differ and require an engineering review.