Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power reviews limited supply, exact identity, condition, documentation, and migration evidence.

CI547 3BNP004429R1

/ 4.9
1001 reviews | Need a Specific Revision?
ABB CI547 3BNP004429R1 is a MasterBus 300/300E interface module with slave CPU for Advant Master and Advant OCS control-system communication.
In Stock
Ships by Friday, October 30
Fast Shipping Available
Get a quick price for CI547 3BNP004429R1
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for CI547 3BNP004429R1

  • Manufacturer:
    ABB
  • Part Number:
    CI547 3BNP004429R1
  • Product Family:
    ABB Advant OCS and Advant-800xA
  • Product Type:
    MasterBus 300/300E Interface Module
  • Stock:
    1
  • ABB product ID:
    3BNP004429R1
  • Interface:
    MasterBus 300 / MasterBus 300E
  • Processing:
    Includes slave CPU
  • System family:
    Advant Master / Advant OCS
  • Lifecycle phase:
    Limited from 1 July 2025
  • Supply basis:
    While Supplies Last
  • Weight:
    0.16 kg
  • Estimated shipping dimensions:
    2.1x17x10.1cm
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    Sweden
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals MasterBus Role Limited Supply Bus Restoration Product Applications

Features:

  • Dual bus context: the interface supports documented MasterBus 300 and 300E communication
  • Dedicated processing: ABB includes a slave CPU in the exact module identity
  • Limited lifecycle: supply and services continue only on a best-practical, while-supplies-last basis
ABB CI547 3BNP004429R1 is the documented communication interface for an installed Advant Master or Advant OCS bus position.

Its onboard slave CPU separates interface processing from the broader controller task while preserving the MasterBus node design.

Selection must align the full Product ID, controller and slot, bus version, cabling, node record, software context, and Limited-phase supply risk.

Apter Power supports document review, quotation, and procurement review for the ABB CI547 3BNP004429R1 MasterBus 300/300E Interface Module while OEM supply remains available on a limited, while-supplies-last basis.
ABB CI547 3BNP004429R1 MasterBus 300/300E Interface Module Manuals,Datasheets,Link
Important Notice: No qualified exact-model English PDF is attached. Use the complete product model in every document request.
  • MB300 connection: the module provides the documented interface for the installed bus.
  • MB300E context: the exact identity also covers the enhanced MasterBus environment.
  • Slave processing: the included CPU supports the interface task within the module.
  • Node evidence: bus address and endpoint records must stay with the hardware change.
  • Phase date: ABB places the product in Limited from 1 July 2025.
  • No new manufacture: new modules are no longer produced in this lifecycle phase.
  • Best-practical support: parts and services depend on remaining capability and inventory.
  • Planning consequence: a tested spare and migration study reduce future outage exposure.
  • Before removal: capture controller, slot, node, cables, and diagnostics.
  • Physical release: inspect connectors and cable ends before another module is fitted.
  • Configuration return: restore the approved bus and software records, not a guessed default.
  • Network proof: verify communication and dependent nodes before process release.
  • Advant Master communication: interface a documented controller position with MasterBus 300.
  • Advant OCS maintenance: replace an exact CI547 identity while preserving node and software records.
  • Legacy spare strategy: qualify remaining OEM or tested stock during the Limited phase.
  • Migration preparation: capture the current bus architecture before support availability narrows further.
Description
A legacy Advant controller reaches MasterBus 300 or 300E through CI547 3BNP004429R1, which includes a slave CPU for the interface task. This hardware identity keeps network processing tied to the expected controller and bus position.

Supply planning now shapes the value of CI547 3BNP004429R1. ABB places the product in Limited phase, with new manufacture ended and remaining parts and services offered on a best-practical, while-supplies-last basis.

Before an outage depends on CI547 3BNP004429R1, the controller, slot, node settings, cable endpoints, diagnostics, and software record should be captured and the spare tested. The same evidence also defines a starting point for a longer-term migration decision.
Alternative Names
ABB CI547 ABB CI 547 ABB 3BNP004429R1 ABB 3BNP 004429 R1 CI547 3BNP004429 R1 CI 547 3BNP004429R1 MasterBus 300E interface module MasterBus 300 interface with slave CPU Advant OCS MasterBus interface with slave CPU
Technical notes
For CI547 3BNP004429R1 service, preserve the Advant controller identity, module slot, MasterBus 300/300E configuration, cable endpoints, node records, diagnostics, and software backup. ABB’s Limited phase means new manufacture has ended and supply is while stocks last, so test the spare and document a longer-term migration plan before outage dependence increases.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Can CI547 3BNP004429R1 be treated as an actively manufactured ABB module?
No. ABB’s Limited phase states that new modules are no longer manufactured; parts and services are best-practical and while supplies last.
What should be captured before removing CI547 3BNP004429R1 from an Advant controller?
Capture controller and slot identity, bus version, node and endpoint records, cable labels, diagnostics, and the software or configuration backup.
Should installation proceed if CI547 3BNP004429R1 arrives with an unreadable Product ID?
No. Hold it until the full 3BNP004429R1 identity and module condition are verified, because the shortened family name alone does not close the legacy configuration.
How should a spare CI547 3BNP004429R1 be prepared for an outage?
Bench-check it where the approved procedure permits, preserve test evidence, confirm the exact bus and controller context, and stage cables and rollback records before shutdown.
What must be proven after CI547 3BNP004429R1 is exchanged?
Verify module diagnostics, MasterBus communication, node visibility, dependent controller data paths, and stable operation before releasing the process.
Why should a migration study accompany procurement of CI547 3BNP004429R1?
ABB’s Limited and while-supplies-last position creates increasing future availability risk, so current sourcing should be paired with an architecture and replacement-path record.