ABB CI854BK01 3BSE069449R1 is a two-channel PROFIBUS DP-V1 communication interface package comprising the CI854B module and TP854 baseplate.
In Stock
Ships by Friday, October 30
Fast Shipping Available
Get a quick price for CI854BK01 3BSE069449R1
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for CI854BK01 3BSE069449R1

  • Manufacturer:
    ABB
  • Part Number:
    CI854BK01 3BSE069449R1
  • Product Family:
    ABB Advant OCS and Advant-800xA
  • Product Type:
    PROFIBUS DP-V1 Communication Interface
  • Stock:
    1
  • ABB article number:
    3BSE069449R1
  • Package contents:
    CI854B interface and TP854 baseplate
  • Protocol:
    PROFIBUS DP-V1
  • Communication channels:
    2
  • Network option:
    Line redundancy supported
  • Documented transmission range:
    9.6 kbit/s to 12 Mbit/s
  • Controller family:
    AC 800M
  • Weight:
    0.7 kg
  • Estimated shipping dimensions:
    5.9x18.5x12.75cm
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    Sweden
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals PROFIBUS Integration Redundant Topology Package Service Product Applications

Features:

  • Complete interface package: CI854B and TP854 are supplied under one article identity
  • Two network channels: the interface supports documented PROFIBUS DP-V1 integration
  • Redundancy option: line-redundant topology can be configured where the approved architecture requires it
ABB CI854BK01 3BSE069449R1 connects an AC 800M controller environment to documented PROFIBUS DP-V1 networks.

The package identity keeps the communication module and baseplate together so hardware scope is clear during procurement and service.

Selection must preserve controller compatibility, topology, channel use, addresses, rate, termination, project configuration, and complete ABB article number.

Apter Power supports document review, quotation, and procurement for the ABB CI854BK01 3BSE069449R1 PROFIBUS DP-V1 Communication Interface.
ABB CI854BK01 3BSE069449R1 PROFIBUS DP-V1 Communication Interface Manuals,Datasheets,Link
Important Notice: No qualified exact-model English PDF is attached. Use the complete product model in every document request.
  • DP-V1 interface: the module connects documented field devices to the AC 800M system.
  • Two channels: topology planning can separate or coordinate the available network paths.
  • Address control: every station identity must remain aligned with the controller project.
  • Rate agreement: the bus configuration and connected devices must share a supported transmission setting.
  • Line redundancy: the interface supports a documented redundant PROFIBUS arrangement.
  • Path evidence: both network routes and terminations should be labelled before service.
  • Single-fault test: commissioning should prove the designed response without disrupting the healthy path.
  • Boundary: redundant wiring does not replace controller and device configuration checks.
  • CI854B module: the communication electronics belong to the complete kit identity.
  • TP854 baseplate: receiving must include the documented mounting and connection base.
  • Project backup: preserve Control Builder and network settings before hardware work.
  • Diagnostic release: verify interface, bus, and device status before process return.
  • AC 800M fieldbus integration: connect documented PROFIBUS DP-V1 devices to the controller.
  • Redundant bus architecture: implement the approved two-path topology where availability requires it.
  • Installed-interface maintenance: replace the exact CI854B/TP854 package while retaining project data.
  • Network commissioning: verify addresses, rate, termination, diagnostics, and dependent devices as one controlled task.
Description
The article identity CI854BK01 3BSE069449R1 covers more than a loose interface module: ABB supplies CI854B together with the TP854 baseplate. Treating the pair as one package keeps receiving and installation scope unambiguous.

Two PROFIBUS DP-V1 channels allow CI854BK01 3BSE069449R1 to support the approved AC 800M network arrangement, including line redundancy where configured. Topology, station addresses, bus rate, termination, and project data must still agree before communication is restored.

Current ABB hardware-selector listing gives CI854BK01 3BSE069449R1 an active OEM sourcing path. It supports availability review for the exact article, while condition, stock, and delivery remain matters for quotation and incoming acceptance.
Alternative Names
ABB CI854BK01 ABB CI854B K01 ABB CI 854B K01 ABB 3BSE069449R1 ABB 3BSE 069449 R1 CI854BK01 3BSE069449 R1 CI854B TP854 PROFIBUS package AC 800M PROFIBUS DP-V1 interface ABB CI854BK01 kit
Technical notes
For CI854BK01 3BSE069449R1 installation, confirm the AC 800M controller context, CI854B and TP854 package scope, channel topology, line-redundancy design, station addresses, baud rate, termination, and Control Builder project before connection. Back up the configuration and complete network diagnostics before restoring dependent PROFIBUS devices to automatic operation.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Can CI854BK01 3BSE069449R1 be ordered as only a loose CI854B module?
The exact ABB article is a package containing CI854B and TP854. Clarify any offer that omits the documented baseplate or changes the approved scope.
What should stop installation of CI854BK01 3BSE069449R1 on an AC 800M network?
Stop if controller support, topology, station addresses, rate, termination, package contents, or project configuration conflicts with the approved design.
How should line redundancy be proved after fitting CI854BK01 3BSE069449R1?
Commission both documented paths, confirm stable device communication, then apply the approved single-path fault test while observing interface and controller diagnostics.
Why must the Control Builder project be backed up before changing CI854BK01 3BSE069449R1?
The hardware identity alone does not recreate channel, address, bus, or device settings; the project backup provides the configuration needed to restore the network.
Can CI854BK01 3BSE069449R1 be accepted when the TP854 baseplate is a different revision?
Hold the package until ABB documentation confirms the combination for the installed controller and topology; matching connectors do not prove a supported assembly.
What should a buyer provide when requesting CI854BK01 3BSE069449R1?
Provide the complete article, controller hardware and software context, topology and redundancy needs, network rate, device count, clear photos, condition requirement, and outage timing.