ABB 3BHB005243R0105 KU C755 AE105
ABB 3BHB005243R0105 KU C755 AE105
ABB 3BHB005243R0105 KU C755 AE105
ABB 3BHB005243R0105 KU C755 AE105
ABB 3BHB005243R0105 KU C755 AE105
ABB 3BHB005243R0105 KU C755 AE105
Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports exact GUSP variant review, documentation and quotation.

3BHB005243R0105 KU C755 AE105

/ 4.9
1001 reviews | Need a Specific Revision?
ABB 3BHB005243R0105 KU C755 AE105 is a complete KU C755 AE105 GUSP gate unit power supply listed for ABB drive service.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for 3BHB005243R0105 KU C755 AE105
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 3BHB005243R0105 KU C755 AE105

  • Manufacturer:
    ABB
  • Part Number:
    3BHB005243R0105 KU C755 AE105
  • Product Family:
    ABB Drives
  • Product Type:
    Gate Unit Power Supply GUSP
  • Stock:
    1
  • ABB Product ID:
    3BHB005243R0105
  • ABB Type Designation:
    KU C755 AE105:GUSP
  • Catalog function:
    Gate Unit Power Supply
  • Documented family:
    ABB ACS6000 GUSP
  • Status indication:
    Green and yellow LEDs
  • Part type:
    New
  • Minimum order quantity:
    1 piece
  • Weight:
    3.68 kg
  • Estimated shipping dimensions:
    27.6x18.7x18.8cm
  • Tariff Code:
    85049090
  • Country of origin:
    Finland
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals GUSP Variant LED Diagnosis Converter Service Product Applications

Features:

  • Complete GUSP unit: ABB catalogs the exact R0105 build as a gate unit power supply.
  • Variant-specific identity: AE105 remains distinct from neighboring KUC755 builds.
  • Documented LED states: green and yellow indications support initial fault assessment.
The complete KU C755 AE105 enclosure is the supplied GUSP unit, not only its internal subboard.

ABB maintenance guidance gives the two status LEDs a defined role in checking voltage and load conditions.

Replacement control relies on the exact R0105 suffix, host position, and a verified mechanical and connector match.

Apter Power supports ABB 3BHB005243R0105 KU C755 AE105 Gate Unit Power Supply GUSP documentation, quotation and sourcing coordination.
ABB 3BHB005243R0105 KU C755 AE105 Gate Unit Power Supply GUSP Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Exact Product ID: require 3BHB005243R0105 on the complete unit.
  • Type suffix: preserve KU C755 AE105 rather than shortening to the family name.
  • Variant boundary: other AE10x builds require separate approval.
  • Voltage indication: the yellow LED reports the stabilized-voltage condition.
  • Load indication: the green LED reports whether the load is connected.
  • Fault pattern: flashing indicators can point to a load short circuit.
  • Stored energy: isolate the gate-unit supply and allow discharge before handling.
  • Position record: document the installed converter location and cable arrangement.
  • Restart check: confirm normal LED behavior and the approved converter test sequence.
  • ACS6000 gate-unit supply: service a matching KU C755 AE105 GUSP position.
  • Fault isolation: use the documented LED pattern to guide initial checks.
  • Planned spare: retain an exact R0105 unit for a documented converter build.
Description
ABB maps 3BHB005243R0105 KU C755 AE105 to type KU C755 AE105:GUSP and catalogs it as a gate unit power supply. The R0105 suffix distinguishes this complete unit from other KUC755 variants.

ACS6000 maintenance information for 3BHB005243R0105 KU C755 AE105 describes the GUSP status LEDs used to distinguish stabilized-voltage, connected-load, short-circuit, and no-supply conditions. Those indications provide a documented diagnostic starting point without authorizing internal repair.

Apter Power can support exact-unit quotation for 3BHB005243R0105 KU C755 AE105 when the host converter position and complete label are available.
Alternative Names
3BHB005243R0105 KUC755AE105 3BHB005243R0105 KU C755 AE105 GUSP ABB KUC755 AE105
Technical notes
For 3BHB005243R0105 KU C755 AE105, preserve the R0105 suffix and complete GUSP type before service. Isolate the converter, wait for stored energy to discharge, and record both LED states before removal. Compare enclosure, connectors, mounting, and host position with the spare; do not mix AE103, AE106, AE107, or AE108 builds.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Can 3BHB005243R0106 replace 3BHB005243R0105 KU C755 AE105 during an outage?
Not without manufacturer-supported evidence for the installed converter. The different product ID and AE suffix identify another build, so hold the swap until engineering approves it.
What do both flashing LEDs mean on 3BHB005243R0105 KU C755 AE105?
ABB maintenance guidance associates both flashing LEDs with stabilized voltage being present while the load has a short circuit. Isolate the equipment and follow the approved diagnostic procedure.
Is the small 3BHB005245R0101 subboard the same supplied item as 3BHB005243R0105 KU C755 AE105?
No. ABB identifies 3BHB005245R0101 as a sub-PCBA of complete KUC755 GUSP units. The R0105 order is the complete KU C755 AE105 GUSP.

Product Browsing History