Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports quotations, ABB documentation, load-profile checks, and bypass review.

ACS510-01-025A-4

/ 4.9
1001 reviews | Need a Specific Revision?
ABB ACS510-01-025A-4 is an 11 kW, 25 A, 380-480 V IP21 ACS510 general purpose drive using frame R2.
In Stock
Ships by Friday, October 30
Fast Shipping Available
Get a quick price for ACS510-01-025A-4
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for ACS510-01-025A-4

  • Manufacturer:
    ABB
  • Part Number:
    ACS510-01-025A-4
  • Product Family:
    ABB Drives
  • Product Type:
    ACS510 General Purpose Wall-Mounted Drive
  • Stock:
    1
  • ABB Product ID:
    3ABD00015748-D
  • Input Voltage:
    380 ... 480 V AC
  • Input Frequency:
    47.5 ... 63 Hz
  • Number of Phases:
    3-phase
  • Normal Output Current:
    25 A
  • Normal Output Power:
    11 kW
  • Apparent Power Output:
    17 kV·A
  • Frame Size:
    R2
  • Degree of Protection:
    IP21
  • Enclosure Type:
    NEMA Type 1
  • Mounting:
    Wall-mounted
  • Efficiency Level:
    IE2
  • Standby Loss:
    13 W
  • Temperature Rating:
    40 °C
  • Built-in Communication:
    Modbus
  • Weight:
    8.8 kg
  • Estimated shipping dimensions:
    22.5 x 36.5 x 56.5 cm
  • Tariff Code:
    85044099
  • Country of origin:
    China
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Load Profile Bypass Design Fault Review

Features:

  • 11 kW normal-use power with 25 A output
  • R2 IP21 wall-mounted enclosure
  • Integrated Modbus and internal brake chopper
ACS510-01-025A-4 is the 25 A configuration for 11 kW applications within the R2 mechanical group.

Its control resources can join motor-speed regulation with process references, permissives, alarms, and serial communication in a coordinated automation design.

Release for purchase should follow motor-current and overload checks, protective-device and cable sizing, R2 airflow and access planning, braking review, bypass logic, network ownership, and acceptance criteria.

Availability is subject to Apter Power's current inventory and sourcing confirmation.
ABB ACS510-01-025A-4 ACS510 General Purpose Wall-Mounted Drive Manuals, Datasheets, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ABB ACS510-01-025A-4 ACS510 General Purpose Wall-Mounted Drive Specs

General

  • ManufacturerABB
  • ModelACS510-01-025A-4
  • ConditionNew Original ready stock
  • Product FamilyABB ACS510 Drives
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

11 kW duty verification

  • Current: Check measured or calculated motor current across the full process range.
  • Overload: Document peak torque, duration, repetition, and acceleration requirements.
  • Speed range: Confirm motor cooling and process limits at reduced speed.
  • Stopping: Evaluate coast, ramp, or dynamic braking against the machine risk assessment.

Contactor and interlock controls

  • Isolation: Prevent simultaneous drive output and bypass connection to the motor.
  • Sequence: Define safe transfer, stop, and restart conditions in the control logic.
  • Motor protection: Coordinate protection for both driven and bypass operating modes.
  • Status: Return verified contactor and drive states to the plant controller.

Evidence-based troubleshooting

  • History: Capture the fault code and operating data before any reset.
  • Mechanical load: Inspect binding, process blockage, inertia, and abnormal torque demand.
  • Electrical path: Check supply, motor cable, insulation, terminals, and output contactors.
  • Configuration: Compare motor data, limits, ramps, and command source with the accepted backup.
Description
ACS510-01-025A-4 is the 11 kW normal-use member of the ACS510 R2 range, delivering 25 A for three-phase 380-480 V industrial motor systems.

ACS510-01-025A-4 can coordinate variable-speed pump, fan, or conveyor operation through terminal commands, analog references, relay outputs, local setup, and the integrated Modbus interface.

ACS510-01-025A-4 requires an application review covering torque and overload behavior, bypass or contactor logic, the internal brake chopper, fuse and cable coordination, enclosure cooling, process interlocks, restart policy, and controlled fault recovery.
Alternative Names
ACS510 01 025A 4 ACS51001025A4 3ABD00015748-D ABB ACS510-01-025A-4 ABB 3ABD00015748-D ACS510 11 kW drive 25 A R2 wall-mounted drive ABB general purpose drive 11 kW
Technical notes
Before deploying ACS510-01-025A-4, confirm that the 25 A drive rating covers the motor current and transient load profile rather than relying on the 11 kW value alone. Coordinate the documented 25 A IEC fuse basis, R2 conductor and airflow requirements, bypass interlocks, internal brake-chopper duty, motor isolation, Modbus control ownership, and restart behavior.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How should ACS510-01-025A-4 be selected for a loaded conveyor?
Compare conveyor starting and breakaway torque with the 25 A normal-output rating, then review inertia, acceleration, speed range, stopping method, downhill or overhauling operation, interlocks, duty cycle, and ambient conditions. This verifies the 11 kW selection against the real mechanical load.
Can ACS510-01-025A-4 operate in a bypass-contactor scheme?
ACS510-01-025A-4 may be used only in an engineered, mechanically and electrically interlocked arrangement that prevents line voltage from reaching the drive output. Coordinate the 25 A motor duty, protection, transfer sequence, controls, and safe isolation before approving bypass operation.
Why can ACS510-01-025A-4 trip when a loaded conveyor starts?
Compare the measured starting current with the 25 A rating and review motor data, material loading, brake release, ramp time, current limit, supply dip, cable condition, and required acceleration torque. This determines whether the trip reflects mechanical demand or an electrical problem.
What must be validated after ACS510-01-025A-4 changes to Modbus control?
For ACS510-01-025A-4, test control-word mapping, reference scaling, address and serial settings, local or remote transfer, timeout behavior, permissives, stop priority, fault reset, controller restart, and loss-of-network response while observing the 25 A conveyor duty.
How should the cooling plan reflect the 337 W losses of ACS510-01-025A-4?
ACS510-01-025A-4 has documented 337 W heat dissipation and 88 m³/h cooling airflow in frame R2. Use both values with enclosure temperature, filtration, recirculation, neighboring heat sources, and maintenance intervals so contamination or filter restriction does not remove the required thermal margin.
Which project records distinguish ACS510-01-025A-4 in procurement?
Provide ACS510-01-025A-4, Product ID 3ABD00015748-D, the 11 kW and 25 A duty, R2 layout, 25 A IEC fuse basis, motor and conveyor schedule, bypass and braking scope, quantity, destination, inspection plan, and delivery target. These records prevent a similar R2 rating from being substituted.