Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports quotations, ABB documents, R4 airflow checks, and motor-duty review.

ACS510-01-072A-4

/ 4.9
1001 reviews | Need a Specific Revision?
ABB ACS510-01-072A-4 is a 37 kW, 72 A, 380-480 V IP21 ACS510 wall-mounted general purpose drive in frame R4.
In Stock
Ships by Friday, October 30
Fast Shipping Available
Get a quick price for ACS510-01-072A-4
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for ACS510-01-072A-4

  • Manufacturer:
    ABB
  • Part Number:
    ACS510-01-072A-4
  • Product Family:
    ABB Drives
  • Product Type:
    ACS510 General Purpose Wall-Mounted Drive
  • Stock:
    1
  • ABB Product ID:
    3ABD00015753-D
  • Input Voltage:
    380 ... 480 V AC
  • Input Frequency:
    47.5 ... 63 Hz
  • Number of Phases:
    3-phase
  • Normal Output Current:
    72 A
  • Normal Output Power:
    37 kW
  • Apparent Power Output:
    50 kV·A
  • Frame Size:
    R4
  • Degree of Protection:
    IP21
  • Enclosure Type:
    NEMA Type 1
  • Mounting:
    Wall-mounted
  • Efficiency Level:
    IE2
  • Standby Loss:
    17 W
  • Temperature Rating:
    40 °C
  • Built-in Communication:
    Modbus
  • Weight:
    22.5 kg
  • Estimated shipping dimensions:
    25.7 x 72.3 x 30.6 cm
  • Tariff Code:
    85044099
  • Country of origin:
    China
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Airflow Design Motor Duty Service Planning

Features:

  • 37 kW normal-use output rated 72 A
  • R4 IP21 wall-mounted drive format
  • 1120 W documented heat dissipation at rated operation
ACS510-01-072A-4 is the 72 A, 37 kW member of the R4 ACS510 range.

Its power section and control platform can integrate a larger motor feeder with process references, permissives, status, network supervision, and a planned maintenance strategy.

Selection should account for load torque and inertia, protection and conductors, R4 mounting and heat removal, stopping method, signal and communication ownership, inspection access, and formal commissioning evidence.

Availability is subject to Apter Power's current inventory and sourcing confirmation.
ABB ACS510-01-072A-4 ACS510 General Purpose Wall-Mounted Drive Manuals, Datasheets, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ABB ACS510-01-072A-4 ACS510 General Purpose Wall-Mounted Drive Specs

General

  • ManufacturerABB
  • ModelACS510-01-072A-4
  • ConditionNew Original ready stock
  • Product FamilyABB ACS510 Drives
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

R4 thermal operating margin

  • Heat loss: Include the documented losses and neighboring equipment in the calculation.
  • Air volume: Maintain the specified cooling-air quantity through the complete enclosure path.
  • Contamination: Select filtration and cleaning intervals for the actual site environment.
  • Derating: Apply ABB limits for elevated temperature, altitude, and switching frequency.

37 kW load and stopping review

  • Current: Use motor nameplate and measured duty current to verify selection.
  • Inertia: Calculate acceleration and deceleration torque over the required cycle.
  • Minimum speed: Protect motor cooling and process limits during extended low-speed operation.
  • Regeneration: Define coast, ramp, or approved braking hardware for the load.

Operational readiness for R4

  • Inspection: Schedule fan, airflow, terminal, cable, and contamination checks.
  • Backups: Keep accepted parameters, network configuration, and motor data under revision control.
  • Spares: Identify critical fan, panel, communication, and protection components.
  • Recovery: Document isolation, diagnosis, parameter restore, and return-to-service tests.
Description
ACS510-01-072A-4 places a 37 kW normal-use motor rating and 72 A output in the ACS510 R4 frame for three-phase 380-480 V industrial systems.

ACS510-01-072A-4 supports process-oriented speed control with local operation, configurable I/O, relay status, and Modbus communication for substantial fan, pump, conveyor, and utility loads.

ACS510-01-072A-4 requires early coordination of motor duty, enclosure heat and airflow, feeder and conductors, lifting and mounting, stop and braking behavior, process controls, service strategy, and site acceptance responsibilities.
Alternative Names
ACS510 01 072A 4 ACS51001072A4 3ABD00015753-D ABB ACS510-01-072A-4 ABB 3ABD00015753-D ACS510 37 kW drive 72 A R4 wall-mounted drive ABB general purpose drive 37 kW
Technical notes
Before assigning ACS510-01-072A-4 to a 37 kW load, confirm the documented 72 A rating against motor current and overload demand. The R4 installation requires the 80 A IEC fuse basis, 1120 W heat dissipation, 280 m³/h airflow, large-conductor and PE design, stopping-duty review, Modbus command boundaries, maintenance access, and loaded acceptance records.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How should ACS510-01-072A-4 be checked for a 37 kW pump or fan?
Compare actual motor current with the 72 A rating, then review the load curve, starting and stopping behavior, speed range, process limits, duty cycle, ambient and altitude, cable length, and protection. This confirms whether the R4 configuration fits the real pump or fan duty.
What does the 1120 W heat load of ACS510-01-072A-4 mean for its R4 cabinet?
ACS510-01-072A-4 combines 1120 W documented losses with a 280 m³/h airflow requirement. Include ambient temperature, enclosure rating, filter pressure drop, recirculation, fan performance, altitude, and neighboring heat sources so the 72 A drive retains an adequate thermal margin.
Why can motor current rise during reduced-speed ACS510-01-072A-4 operation?
For ACS510-01-072A-4, compare the observed value with the 72 A limit and investigate process torque, motor cooling, mechanical drag, resonance, motor data, voltage or phase issues, minimum-speed operation, and control settings. This distinguishes process overload from a configuration or motor problem.
Can ACS510-01-072A-4 be used for rapid cyclic stopping?
Only after calculating regenerative energy, repetition, thermal limits, DC-bus response, motor duty, and the required safe stopping method for the 37 kW load. Because this is an R4 drive, verify the external chopper and resistor scope rather than assuming a smaller-frame internal arrangement.
Which post-trip records are most useful for ACS510-01-072A-4?
Capture ACS510-01-072A-4 fault and event data, current relative to 72 A, speed, temperature, command source, process conditions, network state, and recent parameter or wiring changes before corrective testing. These records link the R4 trip to its actual load and control state.
What should be supplied when sourcing ACS510-01-072A-4?
Provide ACS510-01-072A-4, Product ID 3ABD00015753-D, the 37 kW and 72 A duty, R4 enclosure, 80 A IEC fuse basis, 1120 W thermal load, motor and cable data, braking, I/O and network scope, quantity, destination, inspection, and timing.

Product Browsing History