Features:
- 4 kW normal-use output rated 9.4 A
- Compact R1 wall-mounted IP21 construction
- Built-in Modbus interface and assistant control panel
ACS510-01-09A4-4 is the 9.4 A entry for compact 4 kW motor-control duties on 380-480 V networks.
Its R1 construction suits smaller panels, but final sizing still depends on actual motor current, load behavior, ambient conditions, and the required acceleration and stopping profile.
Project preparation should cover protective-device coordination, PE and shield termination, control wiring, motor data, parameter ownership, and a safe first-run sequence.
Availability is subject to Apter Power's current inventory and sourcing confirmation.
ABB ACS510-01-09A4-4 ACS510 General Purpose Wall-Mounted Drive Manuals, Datasheets, Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ABB ACS510-01-09A4-4 ACS510 General Purpose Wall-Mounted Drive Specs
General
- ManufacturerABB
- ModelACS510-01-09A4-4
- ConditionNew Original ready stock
- Product FamilyABB ACS510 Drives
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Compact-drive selection checks
- Motor current: Use the nameplate current and load duty rather than selecting by 4 kW alone.
- Starting demand: Review inertia, breakaway torque, ramp time, and available current before commissioning.
- Braking: Decide whether the internal chopper requires an approved resistor for the stopping duty.
- Derating: Apply ABB instructions when temperature, altitude, or switching frequency exceeds the base conditions.
Signals and serial communication
- Control source: Define whether commands originate from the panel, terminals, or Modbus.
- Analog reference: Verify signal type, scaling, shielding, and loss behavior before connecting the speed reference.
- Digital inputs: Map run, enable, direction, reset, and interlocks to the approved logic.
- Modbus: Document address, baud rate, parity, command ownership, and timeout response.
R1 commissioning sequence
- Isolation: Confirm safe isolation and PE continuity before touching power or motor terminals.
- Motor data: Enter the complete nameplate values and verify rotation under controlled conditions.
- Interlocks: Test stop, enable, process permissives, and fault reset before applying load.
- Records: Archive accepted parameters, wiring, fault history, and initial operating readings.