Features:
- 37 kW normal-use output rated 73 A
- Published 61 A / 30 kW heavy-duty point
- IP21 ACS580-01 construction in the R4 frame
ACS580-01-073A-4 3AUA0000080499 is the 37 kW R4 drive configuration for 380–480 V three-phase supplies.
Its control platform can translate plant references and permissives into variable motor operation while reporting status and faults to local or supervisory control.
Approval should depend on a documented duty cycle, ambient and altitude review, feeder coordination, motor-cable design, airflow study, signal list, safety validation, and controlled startup plan.
Availability is subject to Apter Power's current inventory and sourcing confirmation.
ABB ACS580-01-073A-4 3AUA0000080499 ACS580 General Purpose Wall-Mounted Drive Manuals, Datasheets, Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ABB ACS580-01-073A-4 3AUA0000080499 ACS580 General Purpose Wall-Mounted Drive Specs
General
- ManufacturerABB
- ModelACS580-01-073A-4 3AUA0000080499
- ConditionNew Original ready stock
- Product FamilyABB ACS580-01 Drives
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
R4 cooling assessment
- Heat source: Include drive losses at the real load and switching frequency in the enclosure model.
- Airflow: Maintain the documented direction and prevent hot-air recirculation.
- Ambient: Apply ABB derating when temperature or altitude exceeds the base conditions.
- Monitoring: Record drive temperature during acceptance at representative process load.
Reference and interlock design
- Speed reference: Define normal, fallback, and maintenance reference sources.
- Permissives: Map process-ready, safety, and equipment interlocks before logic testing.
- Feedback: Select the operating values and alarm states required by the plant system.
- Restart: Document restart behavior after faults, STO events, and supply restoration.
37 kW commissioning evidence
- Pre-power checks: Complete insulation, PE, terminal, and control-wiring inspections.
- No-load test: Verify direction, command sources, references, and safety behavior at low speed.
- Loaded run: Observe current, temperature, vibration, and process stability across the operating range.
- Handover: Freeze parameters, drawings, backups, alarms, and maintenance responsibilities.