ABB ACS880-01-105A-3 3AUA0000108025 is a 55 kW, 105 A, 400 V ACS880-01 IP21 wall-mounted industrial drive in frame R6.
In Stock
Ships by Friday, October 30
Fast Shipping Available
Get a quick price for ACS880-01-105A-3 3AUA0000108025
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for ACS880-01-105A-3 3AUA0000108025

  • Manufacturer:
    ABB
  • Part Number:
    ACS880-01-105A-3 3AUA0000108025
  • Product Family:
    ABB Drives
  • Product Type:
    ACS880 Industrial Wall-Mounted Single Drive
  • Stock:
    1
  • ABB Product ID:
    3AUA0000108025
  • Nominal Motor Power:
    55 kW
  • Normal Output Current:
    105 A
  • Light-Duty Rating:
    100 A / 55 kW
  • Heavy-Duty Rating:
    87 A / 45 kW
  • Maximum Output Current:
    148 A
  • Frame Size:
    R6
  • Input:
    3-phase, 380–415 V AC
  • Input Frequency:
    47.5–63 Hz
  • Protection:
    IP21 / NEMA Type 1
  • Mounting:
    Wall-mounted
  • Control I/O:
    2 AI, 2 AO, 6 DI, 2 DO
  • Apparent Power Output:
    73 kVA
  • Power Consumption:
    1215 W
  • Sound Pressure:
    68 dB(A)
  • Maximum Temperature Rating:
    40 °C
  • Weight:
    42.2 kg
  • Estimated shipping dimensions:
    87x57.8x32.5cm
  • Tariff Code:
    85044087
  • Country of origin:
    Sweden
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Project Planning Motor & Braking Commissioning

Features:

  • 55 kW and 105 A normal-use rating at 400 V
  • R6 wall-mounted enclosure with IP21 protection
  • Direct Torque Control with built-in Safe Torque Off
ACS880-01-105A-3 3AUA0000108025 is the 55 kW, 105 A normal-use configuration in ABB’s ACS880-01 industrial drive range.

ACS880-01-105A-3 3AUA0000108025 uses the R6 mechanical format and provides the documented current ratings needed to evaluate normal, light-overload, and heavy-duty motor applications.

ACS880-01-105A-3 3AUA0000108025 should be ordered after the motor schedule, duty cycle, supply and earthing, protection, cabling, cooling, braking, safety circuit, and option scope have been approved.

Availability is subject to Apter Power's current inventory and sourcing confirmation.
ABB ACS880-01-105A-3 3AUA0000108025 ACS880 Industrial Wall-Mounted Single Drive Manuals, Datasheets, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ABB ACS880-01-105A-3 3AUA0000108025 ACS880 Industrial Wall-Mounted Single Drive Specs

General

  • ManufacturerABB
  • ModelACS880-01-105A-3 3AUA0000108025
  • ConditionNew Original ready stock
  • Product FamilyABB ACS880-01 Drives
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

R6 delivery and installation scope

  • Handling: Approve the delivery route, lifting method, mounting support, and final orientation for the R6 drive.
  • Electrical design: Coordinate the 105 A normal-use rating with the site fault-current, isolation, protection, and conductor studies.
  • Thermal plan: Provide the documented airflow and keep control, fan, power-terminal, and option-module access clear.
  • Responsibilities: Assign ownership for signals, networks, safety validation, commissioning, records, and maintenance.

55 kW duty review

  • Motor match: Compare nameplate current and load torque with the 105 A normal-use and 87 A heavy-duty points.
  • Acceleration: Calculate starting torque, inertia, ramp time, peak current, and process limits before startup.
  • Braking: Calculate regenerative energy, stopping time, repetition, chopper scope, resistor duty, and thermal protection.
  • Cabling: Verify motor insulation, cable construction, length, routing, shield termination, and bearing-current measures where required.

R6 acceptance controls

  • Pre-power checks: Verify identifiers, options, mounting, PE continuity, insulation, terminations, airflow, and Safe Torque Off wiring.
  • Motor data: Enter the complete motor nameplate values and follow the approved identification procedure.
  • Functional test: Prove direction, commands, references, interlocks, network loss behavior, limits, and loaded response.
  • Handover: Archive firmware, option codes, parameters, test results, fault baseline, drawings, and the recovery procedure.
Description
ACS880-01-105A-3 3AUA0000108025 is the 55 kW, 105 A normal-use ACS880-01 drive configuration in ABB’s larger R6 wall-mounted frame for 380–415 V three-phase installations, with IP21 enclosure protection.

ACS880-01-105A-3 3AUA0000108025 uses Direct Torque Control and the documented I/O and control-unit resources to coordinate high-power motor operation with process commands, feedback, permissives, network interfaces, and Safe Torque Off functions.

ACS880-01-105A-3 3AUA0000108025 must be planned as an R6 installation covering handling, mounting support, 100 A light-duty and 87 A heavy-duty requirements, fault-current protection, large-conductor terminations, heat removal, braking, option scope, safety testing, and maintenance access.
Alternative Names
ACS880 01 105A 3 ACS88001105A3 3AUA0000108025 ABB ACS880-01-105A-3 ABB ACS880-01-105A-3 3AUA0000108025 ACS880 55 kW R6 wall mounted drive ACS880-01-105A-3 105 A industrial drive
Technical notes
Approve the handling route and R6 mounting support before ACS880-01-105A-3 3AUA0000108025 reaches site. The 55 kW, 105 A installation requires a verified 380–415 V feeder study, protective device and high-current cable design, PE and shield terminations, airflow, braking duty, Safe Torque Off wiring, communication ownership, and a controlled commissioning baseline.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
When should the 87 A heavy-duty point override the 55 kW normal-use label during selection of ACS880-01-105A-3 3AUA0000108025?
Use the heavy-duty basis when the process torque and overload profile exceed normal-use assumptions. Compare motor current, peak torque, acceleration, repetition, and recovery with 87 A and 45 kW before confirming the drive.
How should 1215 W of documented loss be incorporated into the installation design for ACS880-01-105A-3 3AUA0000108025?
Add it to the enclosure or room heat balance with ambient conditions, neighboring equipment, ventilation capacity, airflow direction, and ABB derating rules. Maintain the R6 clearances and service access used by the approved design.
A high-inertia load pushes ACS880-01-105A-3 3AUA0000108025 toward 148 A during acceleration; which evidence determines whether this is a setup or sizing issue?
Review motor data, speed and current traces, torque demand, inertia, ramp time, mechanical condition, supply quality, and event duration. Compare the result with 105 A normal-use and 87 A heavy-duty operation before changing limits.
Which differences must be resolved before an existing R6 installation accepts ACS880-01-105A-3 3AUA0000108025?
Check full identifiers, current and duty ratings, mounting support, terminal and conductor requirements, cooling, protection, motor and braking data, I/O, option codes, firmware, parameters, safety functions, and approved drawings.
Before large conductors are ordered, what must the cable plan prove for ACS880-01-105A-3 3AUA0000108025?
Confirm approved conductor and PE sizing, terminal capacity, lug arrangement, bending space, entry direction, shielding, separation from control wiring, protective device coordination, and safe access for installation and maintenance.
How should option codes and parameter ownership be controlled when ACS880-01-105A-3 3AUA0000108025 joins a plant network?
Verify each option against the official order record, assign owners for commands, references, interlocks, Safe Torque Off, feedback, and network-loss behavior, then archive firmware, parameters, drawings, and the accepted recovery copy.