Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports quotations, ABB documentation, duty review, and installation planning.

ACS880-01-145A-3 3AUA0000108026

/ 4.9
1001 reviews | Need a Specific Revision?
ABB ACS880-01-145A-3 3AUA0000108026 is a 75 kW, 145 A, 400 V ACS880-01 IP21 wall-mounted industrial drive in frame R6.
In Stock
Ships by Friday, October 30
Fast Shipping Available
Get a quick price for ACS880-01-145A-3 3AUA0000108026
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for ACS880-01-145A-3 3AUA0000108026

  • Manufacturer:
    ABB
  • Part Number:
    ACS880-01-145A-3 3AUA0000108026
  • Product Family:
    ABB Drives
  • Product Type:
    ACS880 Industrial Wall-Mounted Single Drive
  • Stock:
    1
  • ABB Product ID:
    3AUA0000108026
  • Nominal Motor Power:
    75 kW
  • Normal Output Current:
    145 A
  • Light-Duty Rating:
    138 A / 75 kW
  • Heavy-Duty Rating:
    105 A / 55 kW
  • Maximum Output Current:
    178 A
  • Frame Size:
    R6
  • Input:
    3-phase, 380–415 V AC
  • Input Frequency:
    47.5–63 Hz
  • Protection:
    IP21 / NEMA Type 1
  • Mounting:
    Wall-mounted
  • Control I/O:
    2 AI, 2 AO, 6 DI, 2 DO
  • Apparent Power Output:
    100 kVA
  • Power Consumption:
    1962 W
  • Sound Pressure:
    68 dB(A)
  • Maximum Temperature Rating:
    40 °C
  • Weight:
    42.2 kg
  • Estimated shipping dimensions:
    87x57.8x32.5cm
  • Tariff Code:
    85044087
  • Country of origin:
    Sweden
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Project Planning Motor & Braking Commissioning

Features:

  • 75 kW and 145 A normal-use rating at 400 V
  • R6 wall-mounted enclosure with IP21 protection
  • Direct Torque Control with built-in Safe Torque Off
ACS880-01-145A-3 3AUA0000108026 is the 75 kW, 145 A normal-use configuration in ABB’s ACS880-01 industrial drive range.

ACS880-01-145A-3 3AUA0000108026 uses the R6 mechanical format and provides the documented current ratings needed to evaluate normal, light-overload, and heavy-duty motor applications.

ACS880-01-145A-3 3AUA0000108026 should be ordered after the motor schedule, duty cycle, supply and earthing, protection, cabling, cooling, braking, safety circuit, and option scope have been approved.

Availability is subject to Apter Power's current inventory and sourcing confirmation.
ABB ACS880-01-145A-3 3AUA0000108026 ACS880 Industrial Wall-Mounted Single Drive Manuals, Datasheets, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ABB ACS880-01-145A-3 3AUA0000108026 ACS880 Industrial Wall-Mounted Single Drive Specs

General

  • ManufacturerABB
  • ModelACS880-01-145A-3 3AUA0000108026
  • ConditionNew Original ready stock
  • Product FamilyABB ACS880-01 Drives
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

R6 delivery and installation scope

  • Handling: Approve the delivery route, lifting method, mounting support, and final orientation for the R6 drive.
  • Electrical design: Coordinate the 145 A normal-use rating with the site fault-current, isolation, protection, and conductor studies.
  • Thermal plan: Provide the documented airflow and keep control, fan, power-terminal, and option-module access clear.
  • Responsibilities: Assign ownership for signals, networks, safety validation, commissioning, records, and maintenance.

75 kW duty review

  • Motor match: Compare nameplate current and load torque with the 145 A normal-use and 105 A heavy-duty points.
  • Acceleration: Calculate starting torque, inertia, ramp time, peak current, and process limits before startup.
  • Braking: Calculate regenerative energy, stopping time, repetition, chopper scope, resistor duty, and thermal protection.
  • Cabling: Verify motor insulation, cable construction, length, routing, shield termination, and bearing-current measures where required.

R6 acceptance controls

  • Pre-power checks: Verify identifiers, options, mounting, PE continuity, insulation, terminations, airflow, and Safe Torque Off wiring.
  • Motor data: Enter the complete motor nameplate values and follow the approved identification procedure.
  • Functional test: Prove direction, commands, references, interlocks, network loss behavior, limits, and loaded response.
  • Handover: Archive firmware, option codes, parameters, test results, fault baseline, drawings, and the recovery procedure.
Description
ACS880-01-145A-3 3AUA0000108026 is ABB’s 75 kW, 145 A normal-use ACS880-01 configuration, combining a 380–415 V three-phase input specification with an IP21 R6 wall-mounted enclosure.

ACS880-01-145A-3 3AUA0000108026 brings Direct Torque Control, hardwired control resources, Safe Torque Off, and the ACS880 option architecture into higher-power motor systems that require coordinated commands, feedback, protection, and plant communications.

ACS880-01-145A-3 3AUA0000108026 should be released only when the 138 A light-duty and 105 A heavy-duty points, transport and lifting, R6 support and clearances, feeder isolation, conductor terminations, cooling, braking, motor data, control ownership, and site acceptance have been approved.
Alternative Names
ACS880 01 145A 3 ACS88001145A3 3AUA0000108026 ABB ACS880-01-145A-3 ABB ACS880-01-145A-3 3AUA0000108026 ACS880 75 kW R6 wall mounted drive ACS880-01-145A-3 145 A industrial drive
Technical notes
Before moving ACS880-01-145A-3 3AUA0000108026, approve the R6 lifting method, transport route, mounting structure, and service clearances. Its 75 kW, 145 A installation also requires the 380–415 V protection study, high-current cable and lug design, PE and shield terminations, enclosure airflow, braking calculation, Safe Torque Off validation, option review, and controlled startup.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which load evidence distinguishes 145 A normal-use operation from the 105 A heavy-duty basis for ACS880-01-145A-3 3AUA0000108026?
Use measured or calculated motor current, torque-time profile, overload magnitude, acceleration demand, start frequency, and recovery period. Heavy-duty selection must be checked against 105 A and 55 kW, not inferred from the 75 kW label.
Before the enclosure cooling plan is approved, how should the 1962 W loss of ACS880-01-145A-3 3AUA0000108026 be verified?
Include the documented loss with site ambient, adjacent heat sources, ventilation performance, airflow recirculation, and ABB derating requirements. Confirm that R6 inlet, outlet, terminal, fan, and service areas remain clear.
What should engineers capture when ACS880-01-145A-3 3AUA0000108026 approaches its 178 A maximum output during a process transient?
Record current, speed, torque reference, motor values, ramp command, mechanical load, supply condition, event duration, and fault history. Determine whether the transient fits the approved duty before adjusting protection or control limits.
Which site-readiness checks are required before the R6 unit ACS880-01-145A-3 3AUA0000108026 is moved to its mounting position?
Approve the delivery path, lifting method, staging area, mounting support, orientation, clearances, cable approach, and service access. Keep the equipment protected and follow the ABB handling and installation instructions.
Why is another R6 drive not automatically a like-for-like replacement for ACS880-01-145A-3 3AUA0000108026?
The 145 A rating, protection and conductor design, terminals, cooling duty, motor and braking requirements, control I/O, options, firmware, parameters, safety circuit, and drawings must all match the approved project.
For a 75 kW application using ACS880-01-145A-3 3AUA0000108026, what defines the required braking arrangement?
Calculate regenerative energy, peak power, stopping time, repetition, motor speed range, and thermal duty. Then confirm the approved chopper, resistor, protection, and safe stopping scope instead of assuming a standard accessory package.