- Compact member of the Bulletin 1305 adjustable-frequency drive family
- Input phase determines the applicable published motor and output-current rating
- Documented SCANport connection supports compatible operator and communication adapters
Allen-Bradley 1305-AA03A provides programmable induction-motor speed control in the compact 200/230 V Bulletin 1305 range.
The approved machine configuration establishes the command source, terminal functions, speed reference, frequency limits, stopping method, motor-protection settings, and external adapter arrangement.
Check the complete catalog number, input phase, hardware Series, firmware, saved parameter set, motor data, terminal wiring, protection, grounding, filtering, and installation clearances before commissioning.
Availability, condition, price, and shipping time for 1305-AA03A are confirmed during quotation.
Allen-Bradley 1305-AA03A Bulletin 1305 AC Drive Manuals, Datasheets, Links
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Branch-circuit protection must be selected from the official drive instructions for the installed supply
- Motor overload settings must be based on the connected motor nameplate
- Ground-fault or overcurrent trips require inspection of both the motor leads and motor before drive replacement
- The drive chassis and motor frame require the grounding arrangement specified in the installation manual
- Shielded signal wiring should be terminated according to Rockwell Automation guidance
- RFI-filter effectiveness depends on a short mounting path and solid ground connection
- Start, stop, direction, and speed-reference functions are assigned through documented terminals and parameters
- Two-wire and three-wire control arrangements must not be interchanged without checking the circuit
- The saved parameter set must be compared with the machine drawing before returning the axis to service
- Low-power variable-speed induction-motor control
- 200/230 V machines using documented Bulletin 1305 terminal logic
- Service replacement where the original parameters and hardware Series can be confirmed