Features:
- Kinetix 5100 400 V-class EtherNet/IP indexing Servo Drive
- Dual-port EtherNet/IP with standard I/O and standalone control modes
- Safe Torque Off and auxiliary-feedback interfaces
Allen-Bradley
2198-E4055-ERS accepts 342...528 V rms three-phase input and delivers 5.5 kW, with 24.8 A rms continuous and 37.65 A rms peak output current for up to 1.8 seconds.
Official selection data publishes TLP-B145-250 and TLP-B200-300 motor torque-speed curves for this drive.
Confirm the motor curve, feedback and brake interfaces, 24 V control power, conductor sizing, controller configuration, cable set, branch protection, axis duty, regeneration, enclosure cooling, grounding, and STO wiring before selection or replacement.
Availability, condition, price, and shipping time for 2198-E4055-ERS are confirmed during quotation.
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Maximum power loss is 342 W at the documented 380 V condition
- Maximum power loss is 363 W at the documented 480 V condition
- Line-loss ride-through is documented as 20 ms
- The status display presents drive information and diagnostic messages
- Navigation push buttons provide access to drive display menus
- Separate Module, Network, and Charge indicators report drive status
- Short-circuit current rating is 5000 A rms symmetrical
- UL and CSA input-protection references include the LPJ-35SP fuse and 1489-M3D350 circuit breaker
- The hardwired STO connector provides SB+, SB-, S1/S1C, S2/S2C, and SS+/SS- terminals
- Standalone motion applications using pulse-train, digital-I/O, or analog-I/O control
- Single-axis indexing applications controlled by Micro800 or MicroLogix controllers
- Logix5000 controller applications integrated through Kinetix 5100 Add-On Instructions