Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Discontinued / Obsolete by OEM
    Apter Power supports option audits, condition verification, official documents, legacy sourcing, and successor coordination.

20F11ND022AA0NNNNN

/ 4.9
1001 reviews | Need a Specific Revision?
Allen-Bradley 20F11ND022AA0NNNNN is a 480 V PowerFlex 753 drive with 22 A output, built-in I/O, three option slots, and a 15 HP normal-duty rating.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 20F11ND022AA0NNNNN
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 20F11ND022AA0NNNNN

  • Manufacturer:
    Allen-Bradley
  • Part Number:
    20F11ND022AA0NNNNN
  • Product Family:
    PowerFlex
  • Product Type:
    PowerFlex 753 AC Drive
  • Stock:
    1
  • Input:
    480 V AC, three phase
  • Output current:
    22 A
  • Normal-duty rating:
    15 HP
  • Heavy-duty rating:
    10 HP
  • Frame:
    2
  • Enclosure:
    IP20 / IP00 open type
  • Built-in I/O:
    Included
  • Option slots:
    3
  • Dynamic braking:
    Transistor included
  • Weight:
    7.8 kg
  • Estimated shipping dimensions:
    13.45x42.42x21.2cm
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Built-In I/O Option Cards Migration Product Applications

Features:

  • Application I/O: built-in points support machine-level control assignments
  • Three option slots: installed cards define feedback, communication, safety, or I/O scope
  • Official successor: 20F11ND022JA0NNNNN is listed as the direct replacement
This PowerFlex 753 page is organized around the installed application hardware, not only the 22 A power rating.

A field unit can depend on its option-card combination, so the slot inventory and wiring record must be captured before removal.

The direct-replacement notice narrows sourcing, but machine acceptance still has to prove the inherited control and safety functions.

Apter Power can support 20F11ND022AA0NNNNN option-card identification, official documents, condition review, and successor quotation coordination.
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Signal map: record every used input, output, reference, and common
  • Control source: identify local, terminal, network, and automatic ownership
  • Acceptance: test permissives, interlocks, limits, and fault reset after replacement
  • Card identity: photograph catalog numbers and installed slot positions
  • Engineering role: map each card to feedback, safety, communication, or I/O
  • Successor fit: verify card support and firmware context on the replacement build
  • OEM path: compare the AA0 and JA0 catalog configurations in full
  • Transfer record: preserve parameters, wiring, motor, braking, and safety evidence
  • Commissioning: execute controlled functional, fault, stop, and restart tests
  • Machine-level control: use built-in I/O for documented drive and process signals
  • Option-based systems: add supported feedback, communication, safety, or I/O cards
  • Legacy 480 V equipment: maintain 15 HP normal-duty or 10 HP heavy-duty applications during migration
Description
Designed for application flexibility, 20F11ND022AA0NNNNN is a 480 V PowerFlex 753 drive rated at 22 A, 15 HP normal duty, and 10 HP heavy duty. The Frame 2 open-type unit combines built-in I/O with three option slots.

The application-focused architecture of 20F11ND022AA0NNNNN lets an installed machine assign feedback, communication, safety, or additional I/O through its actual option-card set. A precharge-equipped AC input, filtered common-mode configuration, and braking transistor complete the documented base power build.

Rockwell Automation discontinued 20F11ND022AA0NNNNN on June 30, 2024 and lists 20F11ND022JA0NNNNN as the direct replacement. The replacement notice should be supported by label, option, wiring, parameter, motor, safety, and commissioning checks before the machine is released.
Alternative Names
Allen-Bradley 20F11ND022AA0NNNNN 20F11 ND022 AA0 NNNNN PowerFlex 753 480 V 22 A drive PF753 Frame 2 15 HP drive
Technical notes
Migration scope is the key risk for discontinued 20F11ND022AA0NNNNN. Rockwell Automation identifies 20F11ND022JA0NNNNN as a direct replacement, but the installed I/O, option cards, parameter file, motor, safety circuit, braking, enclosure, and control ownership still require comparison. Prove the replacement through a documented machine acceptance test.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Does the Rockwell direct-replacement notice for 20F11ND022AA0NNNNN eliminate machine-level commissioning?
No. The successor still has to reproduce the installed I/O, option-card, motor, braking, safety, and control relationships before the machine is released.
If a built-in input on 20F11ND022AA0NNNNN changes state in software but the machine does not respond, what should be traced?
Trace the signal from its terminal and common through the assigned function, permissives, and active command source. Replace the drive only after that path shows the input is not being processed correctly.
What is the safe way to transfer an option card from 20F11ND022AA0NNNNN during migration?
First establish official support for the card, destination slot, and firmware context. Preserve its wiring and machine role, and stop the transfer if the replacement documentation does not confirm that combination.
How should a lost parameter set for 20F11ND022AA0NNNNN be rebuilt?
Rebuild it from the actual motor and approved machine design, not from a nearby drive. Use the schematics and operating sequence to restore only the I/O, option, safety, braking, and process functions that are documented.
Which information is most useful before resetting a nuisance trip on 20F11ND022AA0NNNNN?
Preserve the exact fault and the operating state at the time it occurred. Compare current, DC-bus behavior, load condition, and active control path before reset; repeated trips require a controlled stop.
What should a buyer request when sourcing 20F11ND022AA0NNNNN for a legacy line?
The full catalog code and installed option-card inventory are essential. Add the motor-duty requirement and official documentation, and do not accept a 22 A match as proof of functional equivalence.