Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power offers exact-suffix review, official documents, responsive quotation support, and compact-drive sourcing coordination.

25B-D010N104

/ 4.9
1001 reviews | Need a Specific Revision?
Compact Frame B construction and a non-filtered input identify Allen-Bradley 25B-D010N104 as the 4 kW PowerFlex 525 configuration with embedded EtherNet/IP.
In Stock
Ships by Tuesday, November 3
Fast Shipping Available
Get a quick price for 25B-D010N104
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 25B-D010N104

  • Manufacturer:
    Allen-Bradley
  • Part Number:
    25B-D010N104
  • Product Family:
    PowerFlex
  • Product Type:
    AC Drive
  • Stock:
    1
  • Input:
    380–480 V AC, three phase
  • Output current:
    10.5 A
  • Motor rating:
    4 kW / 5 HP
  • Frame:
    B
  • Enclosure:
    IP20 NEMA/Open Type
  • EMC filter:
    Not included
  • Communication:
    Embedded EtherNet/IP
  • Weight:
    1.6 kg
  • Estimated shipping dimensions:
    8.7 × 18.0 × 17.2 cm
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Ethernet Integration Branch Protection Frame B Mounting Product Applications

Features:

  • Compact identity: Frame B PowerFlex 525 for the documented 4 kW / 5 HP duty
  • Catalog boundary: N104 denotes the non-filtered input configuration
  • Control access: embedded EtherNet/IP supports documented command and diagnostic exchange
This catalog number is the smallest physical frame in the current batch, making its mounting format an immediate identification point.

Its network interface and safety input belong to the complete drive architecture; neither changes the motor-current or enclosure limits attached to the exact row.

Selection therefore starts with the full suffix and motor duty, then proceeds to cabinet, protection, and commissioning decisions without borrowing assumptions from a filtered unit.

Apter Power can review 25B-D010N104 identity, official documents, quotation details, and compact-drive sourcing requirements.
25B-D010N104 Manuals, Datasheets, Links Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Network role: use the embedded EtherNet/IP interface for documented drive integration
  • Address record: preserve the commissioned IP settings with the machine files
  • Fault boundary: separate network loss from drive or motor faults before hardware replacement
  • Protection basis: select fuses or circuit breakers from the official 520-Series tables
  • Source details: record voltage, available fault current, and local code requirements
  • Stop condition: do not energize until disconnecting and protective devices are approved
  • Mounting method: use the documented DIN-rail or screw-mount options for Frame B
  • Thermal path: maintain the required airflow and ambient-temperature limits
  • Grounding: connect protective earth and motor ground as shown in the installation instructions
  • Standalone machines: apply variable-speed motor control within the documented 4 kW / 5 HP rating
  • Simple integration: connect the drive to a supported EtherNet/IP control architecture
  • Machine maintenance: retain exact drive and motor data for replacement and recommissioning
Description
Built around the compact Frame B package, 25B-D010N104 serves 4 kW / 5 HP variable-speed motor duties on 380–480 V three-phase supplies. The 10.5 A catalog row and N104 suffix identify the exact non-filtered PowerFlex 525 configuration.

Machine builders can use embedded EtherNet/IP on 25B-D010N104 for supported drive commands and diagnostics while retaining the integral brake transistor and Safe Torque Off function. Each feature remains subject to the official wiring, network, and safety instructions.

The compact format of 25B-D010N104 helps where panel space is limited, but motor duty, branch protection, grounding, and cabinet temperature still govern the final installation. A nearby PowerFlex 525 rating or filtered suffix is not an equivalent order identity.
Revisions

Revision Part #

Also known as

25B-D010N104 Series 1
25B-D010N104 Series 1
Alternative Names
Allen-Bradley 25B-D010N104 Rockwell Automation 25B-D010N104 25B D010 N104 25BD010N104 PowerFlex 525 4 kW drive PowerFlex 525 5 HP drive
Technical notes
The N104 suffix is the decisive selection risk for 25B-D010N104 because it identifies the non-filtered configuration. If the panel specification requires an EMC filter, do not substitute an N114 assumption or an adjacent catalog number; resolve the filter, grounding, and leakage-current design from the documented installation before release.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How should 25B-D010N104 be validated against a 4 kW machine motor before an RFQ?
Compare the motor voltage, full-load current, frequency, duty profile, acceleration demand, and enclosure conditions with the 10.5 A drive record. Stop the selection if the load or overload requirement exceeds the documented rating.
Why can 25B-D010N104 lose EtherNet/IP control while the drive still appears healthy locally?
Local status can remain normal while the controller connection, IP settings, command source, or I/O mapping interrupts network control. Compare the active local and network states, restore only the documented connection, and test the machine under a controlled start condition.
Why can an N114 catalog number not automatically replace 25B-D010N104 in an EMC-sensitive cabinet?
The N104 code is non-filtered, while N114 denotes a filtered configuration. Confirm the site EMC design, grounding, leakage-current implications, and exact order requirement before changing catalog codes.
What cabinet checks reduce thermal trips after 25B-D010N104 is installed?
Verify Frame B orientation, airflow, surrounding temperature, enclosure heat load, and documented spacing. If the cabinet exceeds the published ambient or derating boundary, correct the enclosure design before running the motor.
How should branch protection be selected for 25B-D010N104 rather than copied from a nearby drive?
Use the exact 520-Series protection table with the actual supply and regional code, then document the selected fuse, breaker, and disconnect. A similar frame or horsepower label is not a substitute for the current catalog row.
What information makes a 25B-D010N104 quotation technically actionable?
Provide the full catalog number, Series 1 requirement, motor nameplate, supply voltage, enclosure condition, network role, braking need, and requested documentation. Ask the supplier to confirm the exact label and configuration offered.

Product Browsing History