Allen-Bradley 1756-L62 is a ControlLogix 4 MB memory controller that manages large-scale automation tasks and supports up to 128,000 I/O points.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 1756-L62
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 1756-L62

  • Manufacturer:
    Allen-Bradley
  • Part Number:
    1756-L62
  • Product Family:
    ControlLogix
  • Product Type:
    ControlLogix 4 MB Memory Controller
  • Stock:
    2
  • User memory:
    4 MB
  • I/O memory:
    478 KB
  • Optional nonvolatile memory storage:
    128 MB (1784-CF128)
  • Digital I/O, max:
    128,000
  • Analog I/O, max:
    4000
  • Total I/O, max:
    128,000
  • Replacement battery:
    Series A: 1756-BA1, 1756-BATM, 1756-BATA, Series B: 1756-BA2
  • Current draw @ 5.1V DC:
    1200 mA
  • Current draw @ 24V DC:
    14 mA
  • Power dissipation:
    3.5 W
  • Thermal dissipation:
    11.9 BTU/hr
  • Isolation voltage:
    30V (continuous), basic insulation type, RS-232 to system, Type tested at 720V DC for 60 s
  • Serial cables:
    1756-CP3 or 1747-CP3, right angle connector to controller, straight to serial port, 3 m (9.84 ft)
  • Slot width:
    1
  • Module location:
    Chassis-based, any slot
  • Chassis:
    1756-A4, 1756-A7, 1756-A10, 1756-A13, 1756-A17
  • Power supply, standard:
    1756-PA72, 1756-PA75, 1756-PB72, 1756-PB75
  • Power supply, redundant:
    1756-PA75R, 1756-PB75R, 1756-PSCA2
  • Wire category:
    2 - on RS-232 port
  • North American temperature code:
    T4A
  • Enclosure type rating:
    None (open-style)
  • Temperature, operating:
    0…60 °C (32…140 °F)
  • Temperature, storage:
    -40…85 °C (-40…185 °F)
  • Relative humidity:
    5…95% noncondensing
  • Vibration:
    2 g @ 10…500 Hz
  • Weight:
    0.34 kg
  • Estimated shipping dimensions:
    3.5x14x15.1cm
  • Tariff Code:
    9019101000
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Installation Environment Application Scenarios

Features:

  • Provides 4 MB of user memory and 478 KB of I/O memory to accommodate extensive ControlLogix programs.
  • Supports optional 1784-CF128 nonvolatile memory, enabling battery-free operation and preservation of saved tag data.
  • Works with several ControlLogix chassis sizes and supports both standard and redundant power supply arrangements.
Allen-Bradley 1756-L62 is widely used in manufacturing, process control, and large automation systems where a high number of I/O points must be managed reliably. The controller can support up to 128,000 total I/O points, making it suitable for applications that require significant expansion capability. Its open-style construction allows installation inside industrial control cabinets. Compatibility with redundant power supplies also helps improve system availability.

The architecture of Allen-Bradley 1756-L62 combines memory capacity with communication flexibility. The controller contains 4 MB of user memory and 478 KB dedicated to I/O functions. RS-232 connectivity is available through 1756-CP3 or 1747-CP3 cables, while electrical isolation of the serial interface reaches 30 V continuous. Optional CompactFlash storage can provide nonvolatile memory functionality and reduce dependence on batteries.

Allen-Bradley 1756-L62 is intended for demanding environments where temperature, humidity, and vibration resistance are important considerations. The unit operates between 0 and 60 °C and tolerates noncondensing humidity levels up to 95%. Storage capability extends down to -40 °C and up to 85 °C. Documentation also describes SFC reset behavior in Programmatic Reset and Automatic Reset modes, allowing final scan execution and shutdown processing when configured accordingly.

The 1756-L62 Allen-Bradley ControlLogix 4 MB Memory Controller may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Allen-Bradley 1756-L62 ControlLogix 4 MB Memory Controller Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Allen-Bradley 1756-L62 ControlLogix 4 MB Memory Controller Specs

General

  • Manufacturer Allen-Bradley
  • Model 1756-L62
  • Condition New Original ready stock
  • Product Family 1756-L61,1756-L63,1756-L64
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Must be inserted into any available slot in the ControlLogix rack.
  • After insertion, ensure that the locking clips at both ends of the module are fully closed.
  • Before first use, connect the internal lithium battery to prevent program loss.
  • Connect to a serial or industrial network via the front-end channel or communication module.
  • The ambient temperature during module operation must be maintained between 0 and 60 degrees Celsius.
  • Unused modules must not be stored in environments exceeding -40 to 85 degrees Celsius.
  • The relative humidity of the surrounding air should be maintained between 5% and 95% without condensation.
  • Possesses industrial-grade physical defense for stable operation under vibration interference across the entire 2G frequency band.
  • Suitable for systems requiring the handling of up to 128,000 analog or digital I/O points.
  • Perfectly suited for multi-axis servo collaborative motion control in packaging and high-precision machine tools.
  • Commonly used in large control networks requiring cross-workshop data exchange, such as in automotive assembly lines.
  • Widely deployed in critical dual-machine hot standby control systems in industries such as chemical manufacturing where downtime is not permitted.
Description
Allen-Bradley 1756-L62 belongs to the ControlLogix 5560 family and combines 4 MB of user memory with 478 KB of I/O memory to support complex control strategies. The controller can accommodate as many as 128,000 total I/O points, including up to 4,000 analog I/O channels, making it suitable for extensive process and machine control systems. Each controller is supplied with a battery and a 1747-KY key.

Optional nonvolatile memory is available through a 1784-CF64 or 1784-CF128 industrial CompactFlash card. When nonvolatile memory is installed, Allen-Bradley 1756-L62 can operate without a battery. In that configuration, current tag data remains in the state recorded when the nonvolatile memory was last saved, providing additional protection for application data.

Allen-Bradley 1756-L62 can be mounted in any slot of a 1756-A4, 1756-A7, 1756-A10, 1756-A13, or 1756-A17 chassis. Standard power supplies include 1756-PA72, 1756-PA75, 1756-PB72, and 1756-PB75, while redundant operation is supported by 1756-PA75R, 1756-PB75R, and 1756-PSCA2. The controller occupies one slot and communicates through an RS-232 interface using 1756-CP3 or 1747-CP3 serial cables.

Electrical characteristics include a current draw of 1200 mA at 5.1 V DC and 14 mA at 24 V DC. Power dissipation is rated at 3.5 W, with thermal dissipation reaching 11.9 BTU/hr. The RS-232 interface provides 30 V continuous isolation and has been type tested at 720 V DC for 60 seconds. The controller carries a North American temperature code of T4A and features an open-style enclosure.

Allen-Bradley 1756-L62 operates within temperatures from 0 to 60 °C and can be stored between -40 and 85 °C. Relative humidity ranges from 5 to 95% noncondensing, and vibration resistance reaches 2 g over the 10 to 500 Hz range. Documentation also notes that under specific SFC configurations, reset actions can cause target logic to execute a final scan, allowing timers to continue timing and logic to perform shutdown operations during Automatic Reset or Programmatic Reset modes.
Revisions

Revision Part #

Also known as

1756-L62 Ser A
1756-L62/A, Series A, Rev A
1756-L62 Ser B
1756-L62/B, Series B, Rev B
Alternative Names
1756L62 I756-L62 I756L62 1756-L61 1756-L63 1756-L63XT 1756-L64 1756-L65
Technical notes
The Allen-Bradley 1756-L62 ControlLogix processor maximizes industrial automation efficiency by delivering 4 MB of built-in user memory for seamless handling of complex data-intensive applications.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What memory capacity does Allen-Bradley 1756-L62 provide?
Allen-Bradley 1756-L62 includes 4 MB of user memory and 478 KB of I/O memory for ControlLogix applications requiring substantial program and data storage.
Why can Allen-Bradley 1756-L62 operate without a battery?
Installing a 1784-CF64 or 1784-CF128 industrial CompactFlash card gives Allen-Bradley 1756-L62 nonvolatile memory capability, allowing operation without a battery while preserving saved tag data.
How many I/O points can 1756-L62 support?
The controller handles up to 128,000 total I/O points and allows as many as 4,000 analog I/O channels.
Can 1756-L62 be installed in different chassis sizes?
Yes. 1756-L62 may be placed in any slot of 1756-A4, 1756-A7, 1756-A10, 1756-A13, and 1756-A17 chassis assemblies.