Technical specifications for 1756-OF6VI

  • Manufacturer:
    Allen-Bradley
  • Part Number:
    1756-OF6VI
  • Product Family:
    ControlLogix
  • Product Type:
    ControlLogix 6-Point Isolated Voltage Analog Output Module
  • Stock:
    1
  • Output type:
    isolated voltage analog output
  • Output points:
    6
  • Output range:
    ±10.5 V
  • Channel isolation:
    250 V continuous per point
  • Status indicators:
    module health, calibration, and mode
  • Resolution:
    14 bits across 21 V, 1.3 mV; 13 bits across 10.5 V plus sign bit
  • Output impedance:
    Less than 1 Ω
  • Drive capability:
    Loads greater than 1000 Ω, 10 mA
  • Settling time:
    Less than 2 ms to 95% of final value with resistive loads
  • Calibrated accuracy:
    Better than 0.1% of range at 25 °C
  • Offset drift:
    60 µV/°C typical
  • Gain drift:
    50 ppm/°C nominal; 80 ppm/°C maximum
  • Module error:
    0.5% of range
  • Maximum scan time:
    25 ms floating point; 10 ms integer
  • Tariff Code:
    8538900000
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Voltage Loops Calibration Lifecycle Review Application
  • Provides six individually isolated voltage analog output channels
  • Supports configured signal scaling within the documented ±10.5 V range
  • Requires lifecycle review because the complete model is discontinued

1756-OF6VI is a discontinued Allen-Bradley ControlLogix six-point isolated voltage analog output module.

It is used where the engineered ControlLogix application requires isolated voltage outputs and preserved channel scaling.

Verify the loop documentation, configured ranges, calibration records, wiring, and lifecycle plan before replacement.

Availability, condition, price, and shipping time for 1756-OF6VI are confirmed during quotation.

Allen-Bradley 1756-OF6VI ControlLogix 6-Point Isolated Voltage Analog Output Module Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Match the receiving instrument to the documented voltage-output function
  • Preserve configured channel scaling during controller or module replacement
  • Verify polarity and signal reference at the field device
  • Use approved calibration records for each installed output loop
  • Review mode and calibration indicators before returning a channel to service
  • Confirm process response in a controlled operating condition
  • Recognize that Rockwell Automation lists this complete model as discontinued
  • Do not assume a different analog module is electrically or project compatible
  • Document any approved migration choice against the installed system
  • ControlLogix voltage analog signal loops with individual channel isolation
  • Process-command outputs requiring configured voltage scaling
  • Six-channel voltage output sections of compatible ControlLogix systems
Description
1756-OF6VI is a discontinued Allen-Bradley ControlLogix six-point individually isolated voltage analog output module.

It provides six ±10.5 V output channels with 250 V continuous isolation between outputs and module-health, calibration, and mode indicators.

Before replacement, preserve the controller project, per-channel ranges and scaling, wiring, calibration records, and process-loop acceptance criteria; do not assume a current-output module is interchangeable.
Revisions

Revision Part #

Also known as

1756-OF6VI Ser A
1756-OF6VI/A, Series A, Rev A
Alternative Names
1756-OF6VI 1756 OF6VI 1756OF6VI Allen-Bradley 1756-OF6VI Rockwell Automation 1756-OF6VI ControlLogix 1756-OF6VI
Technical notes
1756-OF6VI Series A is a discontinued isolated voltage-output module; preserve approved scaling and calibration records, and review lifecycle strategy before any replacement decision.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Can 1756-OF6VI provide current-loop outputs?
No. 1756-OF6VI is a voltage analog output module. Confirm the receiving device and the required signal type before selecting a replacement.
What must be preserved when replacing 1756-OF6VI in a calibrated process loop?
Preserve the controller project, channel scaling, output ranges, field wiring, loop documentation, and accepted calibration records before returning the loop to service.
Why can a 1756-OF6VI replacement produce an incorrect process response with no module fault?
Check the configured range, output scaling, external device input range, channel wiring, and loop calibration. A healthy module does not prove a correct analog signal application.
Can 1756-OF6VI be replaced with any six-point analog output module?
No. The replacement must match the voltage-only function, isolation needs, controller support, wiring, and the existing configured signal behavior.
What does an in-calibration indicator on 1756-OF6VI mean for plant operation?
Treat calibration status as part of controlled maintenance. Follow the site-approved procedure and verify the process effect before releasing a channel to automatic control.
Why is lifecycle review required before sourcing 1756-OF6VI?
Rockwell Automation lists 1756-OF6VI as discontinued. Verify the installed system's support plan and any approved migration strategy rather than assuming a drop-in substitute.
How should unused 1756-OF6VI channels be handled during replacement work?
Retain the approved project configuration and field-circuit treatment for unused channels; do not change signal scaling or wiring merely because the channel is unused.