Technical specifications for 1783-ETAP2F

  • Manufacturer:
    Allen-Bradley
  • Part Number:
    1783-ETAP2F
  • Product Family:
    Stratix Managed Switches
  • Product Type:
    1+2 Port EtherNet/IP Taps
  • Stock:
    1
  • Description:
    EtherNet/IP tap:copper port+2 fiber ports
  • Tap type:
    Fiber, dual-port
  • Current consumption, max:
    260 mA @ 24V DC
  • DC power supply voltage rating:
    24V DC (20.4…27.6V DC) CL 2/SELV
  • Isolation voltage:
    30V (continuous), basic insulation type, network channels to power and network channels to network channels, Type tested at 853V AC for 60 s
  • Power consumption, max:
    6.24 W
  • Power dissipation:
    6.24 W
  • Ethernet connections:
    RJ45 connector according to IEC 60603-7, 2- or 4-pair Category 5e minimum cable according to TIA 568-B.1 or Category 5 cable according to ISO/IEC 24702
  • DC power connections:
    One 0.33…3.3 mm2 (22…12 AWG) or two 0.33…1.3 mm2 (22…16 AWG) solid or stranded copper wire rated at 75 °C (167 °F) or greater, 1.2 mm (3/64 in.) insulation max
  • Torque:
    0.6…0.8 N•m (5…7 lb•in) on power connectors
  • Wiring category:
    1 - on power ports, 2 - on communication ports
  • North American temp code:
    T4
  • IEC temp code:
    T4
  • Fiber transceiver type:
    100Base-FX IEEE802.3u
  • Optical wavelength:
    1310 nm no cap
  • Receiver sensitivity, min:
    -31.8 dBm
  • Receiver sensitivity, max:
    -14 dBm
  • Temperature, operating:
    -25…60 °C (-13…140 °F)
  • Temperature, surrounding air, max:
    60° C (140 °F)
  • Temperature, nonoperating:
    -40…85 °C (-40…185 °F)
  • Relative humidity:
    5…95% non condensing
  • Vibration:
    5 g @ 10…500 Hz
  • Shock:
    30 g (operating), 50 g (non operating)
  • Weight:
    0.2 kg
  • Estimated shipping dimensions:
    3.5x10.5x13.7cm
  • Tariff Code:
    7307210000
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Diagnostics Configuration Application Scenarios

Features:

  • Combines copper and dual fiber ports enabling flexible EtherNet/IP network topology configuration.
  • Supports high-speed ring communication with less than 3 ms make/break time and integrated diagnostic capability.
  • Includes IEEE 1588 PTP and QoS functions for synchronized and prioritized industrial network data transmission.
Allen Bradley EtherNet/IP tap 1783-ETAP2F is designed for structured industrial Ethernet communication systems requiring both copper and fiber connectivity. It integrates one copper port and two fiber ports to support EtherNet/IP network architecture under defined electrical and optical parameters. The device operates on 24V DC supply with controlled power consumption and isolation characteristics. The Allen Bradley EtherNet/IP tap 1783-ETAP2F maintains standardized electrical and communication configurations across network layers. It is designed for use in structured communication environments requiring stable signal transmission.

In system configuration, Allen Bradley EtherNet/IP tap 1783-ETAP2F supports linear and device level ring (DLR) topology options. It enables fast recovery communication behavior with defined performance characteristics under ring operation. The device includes diagnostic capability to support structured network monitoring functions. Fiber communication is based on 100Base-FX standard with defined wavelength and sensitivity range. The Allen Bradley EtherNet/IP tap 1783-ETAP2F maintains controlled optical and electrical integration within EtherNet/IP systems.

From a communication architecture perspective, Allen Bradley EtherNet/IP tap 1783-ETAP2F supports IEEE 1588 synchronization and QoS data prioritization functions. It ensures structured data transmission across multiple network nodes with standardized interoperability support. Environmental resistance includes defined operating temperature, humidity, vibration, and shock limits. Electrical installation follows specified wiring and torque requirements for consistent connection integrity. The Allen Bradley EtherNet/IP tap 1783-ETAP2F provides structured network connectivity within industrial Ethernet systems.

The 1783-ETAP2F Allen-Bradley 1+2 Port EtherNet/IP Taps may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Allen-Bradley 1783-ETAP2F 1+2 Port EtherNet/IP Taps Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Allen-Bradley 1783-ETAP2F 1+2 Port EtherNet/IP Taps Specs

General

  • Manufacturer Allen-Bradley
  • Model 1783-ETAP2F
  • Condition New Original ready stock
  • Product Family 1783-ETAP3T,1783-ETAP,1783-ETAP1F
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Status Indication: Real-time monitoring of module operation, ring network integrity, and port connection status via OK, Link, and Network status LEDs on the panel.
  • Fault Warning: When a partial fault is detected, the module automatically adjusts the LNK indicator and prevents the last active port from being disabled to maintain basic communication.
  • Debugging Mode: The device port debugging mode can be enabled via RSLinx software, allowing technicians to directly analyze traffic and troubleshoot locally accessed devices.
  • Management Interface: A built-in web interface allows users to remotely view statistics, port attributes, and network configurations, improving maintenance efficiency.
  • Hardware DIP Switches: Operating modes can be quickly set via DIP switches on the side of the module, such as enabling or disabling the Ring Supervisor function.
  • IP Assignment: Supports IP address assignment via BootP/DHCP or static settings to meet the needs of different network management strategies.
  • Software Integration: Add-on Profiles (AOPs) can be downloaded and configured in the Studio 5000 environment for seamless integration with the Logix control system.
  • Factory Reset: Supports quick factory reset via specific switch combinations, resetting IP addresses to default values ​​for easy device redeployment.
  • DLR Ring Network Access: Securely connects individual devices (such as frequency converters or I/O modules) that do not support embedded switching technology to a Device-Level Ring Network (DLR) to achieve network redundancy.
  • Optical-to-Electronic Media Conversion: Utilizes its two fiber optic ports to bridge long-distance, highly interference-resistant fiber optic backbone networks with local copper cable devices in industrial environments.
  • Topology Expansion: Acts as a node in complex linear or star topologies, enabling flexible expansion of local devices without additional backplanes.
  • System Segmentation Isolation: Connects specific control subsystems to existing EtherNet/IP networks via splitters without interrupting main network operation, reducing cabling complexity and cost.
Description
The Allen Bradley EtherNet/IP tap 1783-ETAP2F is a 1+2 port network tap combining copper and dual fiber connectivity for EtherNet/IP communication systems. It supports 24V DC power supply within 20.4…27.6V DC range and operates with a maximum current consumption of 260 mA. The unit is designed with 6.24 W power consumption and power dissipation under defined electrical limits. Isolation voltage is specified at 30V continuous with basic insulation type between network channels and power channels. The Allen Bradley EtherNet/IP tap 1783-ETAP2F is structured for controlled network signal separation and power management.

Communication design includes RJ45 Ethernet connection compliant with IEC 60603-7 and Category 5e or Category 5 cabling standards. Fiber communication is based on 100Base-FX IEEE802.3u with 1310 nm optical wavelength. Receiver sensitivity ranges from -31.8 dBm to -14 dBm under defined optical conditions. Wiring categories are defined as category 1 for power ports and category 2 for communication ports. The Allen Bradley EtherNet/IP tap 1783-ETAP2F maintains standardized Ethernet physical layer integration.

Environmental specifications define operating temperature from -25 to 60°C and surrounding air maximum temperature of 60°C. Non-operating temperature ranges from -40 to 85°C with relative humidity between 5 and 95% non-condensing. Mechanical performance includes vibration resistance of 5 g at 10…500 Hz and shock resistance of 30 g operating and 50 g non-operating. The Allen Bradley EtherNet/IP tap 1783-ETAP2F is built under defined industrial environmental constraints.

The device supports topology configuration options including linear and device level ring (DLR) structures. It enables high-performance ring operation with make/break time less than 3 ms and diagnostic functions with fast recovery capability. IEEE 1588 precision time protocol (PTP) and Quality of Service (QoS) are included for synchronization and data prioritization. The system is designed with open standard technology supporting third-party interoperability. The Allen Bradley EtherNet/IP tap 1783-ETAP2F ensures structured network communication behavior within defined protocol standards.

Network architecture flexibility is provided through copper and fiber port combination design. Fiber transceiver type supports structured optical transmission within specified wavelength parameters. Electrical connection supports solid or stranded copper wire rated at 75°C or higher with defined insulation limits. Torque requirements for power connectors are specified between 0.6…0.8 N·m. The Allen Bradley EtherNet/IP tap 1783-ETAP2F maintains standardized installation and connection parameters.
Alternative Names
1783-ETAP3T 1783-ETAP1T2SFP 1783-ETAP 1783-ETAP1F 1783ETAP2F 17B3-ETAP2F 17B3ETAP2F I783-ETAP2F I783ETAP2F
Technical notes
Allen Bradley 1783-ETAP2F is a 1+2 port EtherNet/IP tap with copper port and 2 fiber ports, 24V DC supply (20.4…27.6V DC), max current 260 mA, power consumption and dissipation 6.24 W, isolation voltage 30V continuous basic insulation tested at 853V AC for 60 s, RJ45 Ethernet connector per IEC 60603-7 with Category 5e or Category 5 cabling, 100Base-FX IEEE802.3u fiber transceiver, 1310 nm wavelength, receiver sensitivity -31.8 to -14 dBm, operating temperature -25…60°C, storage -40…85°C, humidity 5…95% non-condensing, vibration 5 g 10…500 Hz, shock 30 g operating and 50 g non-operating, torque 0.6…0.8 N·m, wiring category 1 power ports and 2 communication ports.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How does the 1783-ETAP2F handle power input requirements?
It operates on 24V DC with a range of 20.4…27.6V DC and 260 mA maximum current.
What type of network connections does the device support?
It supports one copper port and two fiber ports for EtherNet/IP communication.
What is the function of isolation voltage in this device?
It provides 30V continuous basic insulation between network channels and power channels.
What type of cable is required for Ethernet connections?
Category 5e or Category 5 cable according to IEC and ISO/IEC standards is required.