Features:
- Uses a 2.5 in insertion depth for targets near the external case wall.
- Provides the package 04 single-plug connection arrangement.
- Retains a 0.5 m probe allowance within a stainless-steel protective housing.
This 025 version is the short-reach 24701 configuration selected for the current order.
It secures the probe close to the machine exterior while maintaining covered access to the connection.
Drawing 323933-30-02, standoff length and mounting thread must all match before the old housing is removed.
Apter Power can review sourcing, documentation and system matching for 24701-28-05-XX-025-04-XX MOD 323933-30-02.
Verified resources for Bently Nevada 24701-28-05-XX-025-04-XX MOD 323933-30-02:
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Compact bearing housings can use the short sleeve when the monitored shaft is close to the case surface.
- Machine upgrades can add an external protective cover without creating an unnecessarily long probe support.
- Routine probe-gap service can be performed from outside the equipment after the connection cover is opened.
- The probe and sealing arrangement must remain within the selected 3300 XL 8 mm temperature limits.
- Condensation control depends on intact threads and a fully seated external plug.
- Thermal growth of the machine case should be considered when setting the cold probe gap.
- The short housing still requires a complete thread-engagement and locking check before startup.
- Do not infer hazardous-area suitability unless the installed assembly carries the applicable approval marking.
- Isolation procedures should keep the machine stationary while the probe penetration and gap are adjusted.
- The housing protects the probe connection against accidental contact during normal operation.
- A sudden gap change after service can indicate incorrect locknut position or incomplete thread engagement.
- Cable and connector insulation should be tested if moisture is found beneath the external cover.