Features:
- Serves as the Power Interface Between AC Input and the 3300 Rack Backplane
- Performs AC/DC Power Conversion with Integrated Line Noise Filtering
- Powers Up to 12 Standard 3300 Monitors and Their Associated Transducers
The Bently Nevada 3300/12 AC Power Supply Module serves as the critical interface between the universal AC power source and the 3300 rack backplane, delivering reliable DC power to all connected monitors and transducers within the system. The 3300/12 combines AC/DC power conversion capability with integrated line noise filtering, ensuring clean and stable power distribution throughout the rack. It operates in conjunction with all standard 3300 series monitors and their associated proximity transducers, providing a unified power solution for complete machinery protection systems.
The 3300/12 AC Power Supply Module operates as the primary power source in a 3300 rack, continuously converting incoming AC power (115 Vac or 220 Vac) into regulated DC voltages used by the monitors installed in the rack. The 3300/12 distributes this converted power through the rack backplane to support steady state operation of all connected modules and transducers. Unlike systems requiring redundant power configurations, the 3300/12 is designed so that a second power supply in the same rack is never required, simplifying installation and reducing system complexity while maintaining reliable power delivery.
The 3300/12 provides essential power functions common to the entire 3300 rack, and is a critical component of the monitoring path, directly affecting the proper, normal operation of the overall monitor system. One 3300/12 power supply is required per rack, as the module is engineered to fully support up to 12 monitors and their transducers without additional power units. The 3300/12 occupies the left-most location (position 1) in the 3300 rack, which is the dedicated power supply slot, ensuring optimal power distribution to all installed monitoring modules.
The 3300/12 Bently Nevada AC Power Supply Module may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Bently Nevada 3300/12 AC Power Supply Module Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Bently Nevada 3300/12 AC Power Supply Module Specs
General
- Manufacturer Bently Nevada
- Model 3300/12
- Condition New Original ready stock
- Product Family 3300/20,3300/14,3300/16
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Centralized Rack Powering: Drives up to 12 individual monitors and connected transducers from a single chassis position.
- Chassis Slot Requirement: Installs exclusively in the designated left-most slot (Position 1) of the 3300 series rack.
- Transducer Voltage Supply: Outputs regulated power for standard -24 Vdc proximity sensors and older legacy -18 Vdc hardware.
- Critical Asset Protection: Empowers real-time monitoring systems for industrial gas turbines, steam turbines, large pumps, and compressors.
- Operating Temperature: 0°C to +65°C (+32°F to +150°F).
- Storage Temperature: -40°C to +85°C (-40°F to +185°F).
- Relative Humidity: Maximum 95%, non-condensing.
- Harsh Environment Resilience: Features a sealed housing design with optional conformal coating to resist corrosive atmospheric contaminants.
- Line Noise Filtering: Standard internal filtration blocks incoming electrical spikes and baseline power grid noise.
- Overcurrent Shielding: Employs a 1.5 Amp slow-blow fuse to absorb transient power-up inrush currents reaching 26 Amps peak.
- Voltage Status Monitoring: Features a front-panel "Supplies OK" LED that automatically deactivates if internal DC voltage outputs drift.
- False Alarm Invalidation: Enforces a 2-second automatic alarm inhibit upon startup to let voltages stabilize before monitoring begins.
- System Interlocking: Interfaces with the 3300/03 System Monitor to open a normally energized OK Relay when critical power failures occur.