Features:
- TipLoc Probe-Tip Construction
- System-Level EMC and RFI Performance
- ClickLoc Secure Locking Mechanism
The 3300 XL probe uses Bently Nevada’s TipLoc molding method to provide a robust bond between the probe tip and probe body. Its CableLoc design provides a rated pull strength of 330 N (75 lbf) between the probe case and probe lead.
When connected as part of a complete 3300 XL 8 mm system, the system supports vibration and position measurements. EMC and RFI performance depends on the complete installed transducer system and wiring configuration.
The probe uses a miniature coaxial ClickLoc connector. The locking mechanism helps prevent the connector from loosening, and two 3300 XL ClickLoc connectors are tightened finger-tight.
No official OEM end-of-life notice for 330101-00-39-10-02-05 was identified in the reviewed Bently Nevada documentation. Availability should be confirmed at the time of quotation.
Bently Nevada 330101-00-39-10-02-05 3300 XL 8 mm Proximity Transducer Probe Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Bently Nevada 330101-00-39-10-02-05 3300 XL 8 mm Proximity Probe
General
- Manufacturer Bently Nevada
- Model 330101-00-39-10-02-05
- Condition New — subject to verification against the actual item and quotation
- Product Family 3300 XL 8 mm Proximity Probe
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Radial vibration measurement on fluid-film bearing machines
- Axial or shaft position measurement
- Keyphasor phase-reference measurement
- Speed measurement, subject to the application guidance specified by Bently Nevada
- Standard probe operating and storage temperature: -52°C to +177°C (-62°F to +350°F).
- Avoid exposure below -34°C (-30°F) where premature pressure-seal failure is a concern.
- Minimum cable bend radius: 25.4 mm (1.0 in).
- The exact hazardous-area installation conditions must be verified against the applicable approval certificate and installation drawing.
- The probe connects to a compatible 1-meter 3300 XL Proximitor Sensor.
- The complete transducer system produces an output voltage proportional to the distance between the probe tip and the observed conductive surface.
- The system can measure static position and dynamic vibration values.
- Monitor and software compatibility must be verified for the selected monitoring channel and configuration.