Features:
- The 1/4-28 UNF case is continuously threaded over a 3.6 in overall length.
- A 1.0 m unarmored FluidLoc lead ends at a protected miniature coaxial ClickLoc connector.
- The matched NSv system provides a 1.5 mm linear range around the specified target gap.
Bently Nevada 330901-00-36-10-11-05 brings the NSv sensing tip to the target through an adjustable threaded body.
The FluidLoc lead transfers the probe response to the protected extension-cable junction.
A matched extension cable and NSv Proximitor Sensor condition the signal before it reaches the monitor.
The Bently Nevada 330901-00-36-10-11-05 3300 XL NSv Proximity Probe may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Bently Nevada 330901-00-36-10-11-05 3300 XL NSv Proximity Probe Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Continuous Threaded Geometry
- Thread: The probe body uses a 1/4-28 UNF mounting thread.
- Plain section: Option 00 leaves no unthreaded length ahead of the case.
- Reach: The complete case extends 3.6 in from the sensing end to the cable transition.
- Adjustment: Axial movement of the threaded body establishes the final target gap.
Integral Cable Path
- Length: The integral lead contributes 1.0 m to the transducer system length.
- Construction: FluidLoc cable is used without external armor.
- Bend: Routing must preserve at least the documented 25.4 mm bend radius.
- Support: Clamps must restrain the cable without loading the probe or connector.
Protected Signal Junction
- Connector: The probe lead terminates in a miniature coaxial ClickLoc interface.
- Protector: A connector protector covers the installed junction.
- Mating: The extension-cable connector must be fully seated before the loop is tested.
- Separation: Mechanical protection at the junction does not replace strain relief along the lead.
NSv Measurement Behavior
- Gap: A 1.0 mm setting places the target near the recommended operating point.
- Range: The matched transducer chain provides 1.5 mm of linear measurement.
- Scale: Target movement changes the conditioned output by 7.87 V/mm.
- Bandwidth: Dynamic response extends from 0 to 10 kHz.