Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power confirms CE4033S2B10 software fit and hardware scope before quotation.

CE4033S2B10

/ 4.9
1001 reviews | Need a Specific Revision?
Emerson CE4033S2B10 is a redundant DeltaV M-series 16-channel 4-20 mA HART analog input Plus assembly for 2-wire and 4-wire transmitters.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for CE4033S2B10
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for CE4033S2B10

  • Manufacturer:
    Emerson
  • Part Number:
    CE4033S2B10
  • Product Family:
    DeltaV
  • Product Type:
    DeltaV Redundant 16-Channel 4-20 mA HART Analog Input Plus Card and Terminal Block
  • Stock:
    1
  • Channels:
    16
  • Signal Type:
    4-20 mA with HART
  • Card Platform:
    Traditional I/O Plus
  • Termination:
    Redundant terminal block for 2-wire and 4-wire inputs
  • Minimum DeltaV Version:
    v13.3.1
  • Architecture:
    DeltaV M-series redundant analog input
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Input Continuity Transmitter Signal Path Plus Platform Fit Product Applications

Features:

  • Recoverable input electronics: A standby path lets maintenance restore card protection without rebuilding the field termination.
  • Flexible transmitter landing: The common block supports the documented power arrangements without requiring separate input groups.
  • Instrument context: Compatible HART status accompanies the process current and adds information beyond the measured value.
CE4033S2B10 sits between a group of HART transmitters and the DeltaV control modules that consume their measurements.

The field conductors remain at one redundant termination while DeltaV monitors which electronic path is active and whether the standby remains available.

This makes the assembly useful when a plant wants a card fault to become a managed maintenance event instead of an immediate loss of the complete measurement group.

Apter Power can help confirm the software, carrier and redundant wiring fit for the Emerson CE4033S2B10 DeltaV Redundant 16-Channel 4-20 mA HART Analog Input Plus Card and Terminal Block before quotation.
Emerson CE4033S2B10 DeltaV Redundant 16-Channel 4-20 mA HART Analog Input Plus Card and Terminal Block Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • One logical input group: DeltaV presents the active and standby electronics as a redundant resource rather than requiring separate control-module references.
  • Automatic fault response: The controller scans both cards and can transfer input duty when the active side or its communication path reports a fault.
  • Stable field termination: Transmitter conductors remain at the common redundant block while the electronic pair is monitored or serviced.
  • Visible recovery state: Hardware alerts and diagnostics expose both card conditions so restored redundancy can be proven after an intervention.
  • Power-method flexibility: The field interface accommodates transmitters powered from the loop and instruments powered by a separate supply.
  • Correct supply ownership: Each channel must preserve the power and return arrangement that belongs to its transmitter type.
  • Analog and digital context: The process current and compatible HART information share the loop but provide different evidence about device condition.
  • Independent channel boundary: Optical isolation from the system helps contain investigation to the affected input circuit.
  • Software dependency: Traditional I/O Plus capability must exist in the installed DeltaV release before the hardware can be selected.
  • M-series carrier dependency: The input assembly mounts in the M-series I/O architecture rather than the physically different S-series controller carrier.
  • Complete redundant scope: Both electronic positions and the common terminal block are necessary to deliver the intended availability benefit.
  • Keyed signal identity: Card keying and the full order code protect the position from a simplex or different-signal substitution.
  • Redundant analog measurement groups: Maintains an alternate electronic path for M-series 4–20 mA HART inputs.
  • Mixed transmitter power methods: Lands documented two-wire and four-wire current transmitters on one redundant input assembly.
  • HART device maintenance: Carries supported device status alongside the process measurement for DeltaV maintenance workflows.
  • Traditional I/O Plus projects: Adds higher-density analog input while retaining the M-series control architecture.
Description
CE4033S2B10 is a redundant DeltaV M-series analog-input Plus assembly for bringing critical process measurements from both loop-powered and externally powered HART transmitters into the control system. Its paired electronics are intended to keep the measurement group available when one input-card path is unavailable.

The main advantage of CE4033S2B10 is that availability, mixed transmitter wiring and device visibility are handled through one coordinated input assembly. This makes it useful where operations need measurement continuity without giving up the diagnostic context carried by compatible smart instruments.
Technical notes
Verify that the installed DeltaV release supports the Traditional I/O Plus platform before fitting CE4033S2B10. Confirm the redundant card pair, 2-wire or 4-wire transmitter wiring, field supply and M-series carrier before installation. Do not infer fit from a similar terminal-block outline, and record both primary and standby card positions.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Will CE4033S2B10 keep a four-wire transmitter measurement available if the shared external transmitter supply fails?
No. The redundant cards protect the input-electronics path, not the independent field power source. Provide the required power-system resilience or separate the supply risk; two healthy cards cannot measure a transmitter that has lost operating power.
CE4033S2B10 switched to its standby card immediately after field-terminal work. What should be investigated before replacing electronics?
Read the hardware alert and Event Chronicle, then inspect the affected field wiring because a detected wiring fault can cause a switchover. Replace a card only when diagnostics identify the electronic path rather than the recently disturbed loop.
A loop-powered transmitter needs more than 13.5 V at 20 mA after cable loss is included. Is CE4033S2B10 a suitable power path?
Not on that requirement. The published transmitter-power point is 13.5 V minimum at 20 mA. Reduce the loop burden, provide an approved external supply arrangement or select another interface before commissioning.
A transmitter connected to CE4033S2B10 rises above 22 mA during a fault. Should DeltaV treat that value as a valid extension of the process range?
No. The published full-signal range ends at 22 mA. Configure and test the project response as an overrange or fault condition rather than scaling it into normal measurement service.
Can CE4033S2B10 create two independent measurements from one transmitter simply because it contains an active and standby card?
No. The pair duplicates the I/O electronics connected to the same field signal; it does not create a second sensor or an independent process tap. Use separate transmitters and an engineered voting strategy when sensor redundancy is required.
CE4033S2B10 does not require routine card calibration. Can a replacement be returned to service without an end-to-end loop test?
No. The no-calibration design concerns the module reference, not channel identity or field wiring. Prove the transmitter value through the correct terminal and DeltaV point before the measurement is released to control.