    Apter Power supports IS analog-channel and HART compatibility review.

SE4307T01

/ 4.9
1001 reviews | Need a Specific Revision?
Emerson SE4307T01 is a DeltaV intrinsically safe 4-20 mA HART analog-input CHARM for receiving transmitter signals through compatible IS baseplate and terminal hardware.
In Stock
Fast Shipping Available
Get a quick price for SE4307T01
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for SE4307T01

  • Manufacturer:
    Emerson
  • Part Number:
    SE4307T01
  • Product Family:
    DeltaV
  • Product Type:
    DeltaV Intrinsically Safe 4-20 mA HART Analog Input CHARM
  • Stock:
    1
  • Signal:
    4-20 mA
  • Digital Protocol:
    HART
  • Channel Architecture:
    Single channel
  • Marshalling:
    DeltaV IS Electronic Marshalling
  • Required Hardware:
    Compatible IS baseplate and terminal block
  • Device Data:
    Process variable and supported HART information
  • Area Use:
    Per approved IS system configuration
  • Reference Document:
    IS Electronic Marshalling AI HART ordering table
  • Tariff Code:
    Please confirm the destination before shipping.
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Applications Environmental Ratings Monitoring Safety

Features:

  • Accepts one 4-20 mA analog input from a compatible process instrument.
  • Carries HART communication on the channel for supported device information and maintenance access.
  • Establishes intrinsic-safety isolation through the approved CHARM and its matched termination assembly.
The current ordering configuration is SE4307T01, the DeltaV Intrinsically Safe 4-20 mA HART Analog Input CHARM documented by Emerson for DeltaV IS Electronic Marshalling.

SE4307T01 is used in IS transmitter loops that provide a 4-20 mA process variable and HART data. Its system role and configuration limits must remain aligned with the official specification.

Before commissioning SE4307T01, verify the installed assembly, project wiring, power, software and environmental conditions that apply to this exact part number.

Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Emerson SE4307T01: Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • IS transmitter loops that provide a 4-20 mA process variable and HART data.
  • Electronic-marshalling designs that configure each analog channel independently.
  • Maintenance of one intrinsically safe input without replacing a multi-channel analog card.
  • Use the CHARM within the approved IS electronic-marshalling enclosure.
  • Observe the product-label temperature and hazardous-area markings.
  • Maintain separation and installation conditions required by the IS baseplate.
  • Monitor the analog process variable and channel diagnostics in DeltaV.
  • Review supported HART status data when transmitter health is questioned.
  • Distinguish loop-current faults from communication faults during troubleshooting.
  • Verify intrinsic-safety entity parameters before connecting the transmitter loop.
  • Use only the terminal assembly approved for SE4307T01 service.
  • Follow the site's hazardous-area isolation procedure before replacement.
Description
SE4307T01 is an Emerson DeltaV single-channel intrinsically safe analog-input CHARM for 4-20 mA field transmitters with HART communication. Its code is explicitly listed in the current IS Electronic Marshalling ordering table.

The channel converts the analog process signal while carrying supported HART device information through the DeltaV marshalling architecture. Installation requires the compatible IS CHARM baseplate and terminal block specified for the project.

Confirm loop power, barrier parameters, HART device support, terminal selection, area classification and channel assignment before commissioning the SE4307T01 input.
Alternative Names
SE4307T01 SE4307 T01 SE4307-T01 Emerson SE4307T01 DeltaV IS SE4307T01 SE4307T01 4-20 mA HART Analog Input CHARM Emerson DeltaV Intrinsically Safe Analog Input CHARM
Technical notes
SE4307T01 is the IS analog-input CHARM for 4-20 mA HART service; it must not be configured as the adjacent DO or AO variants.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which field signal is assigned to SE4307T01?
It is the intrinsically safe 4-20 mA HART analog-input CHARM.
Does the channel carry HART information?
Yes. The official product family supports HART communication for this analog-input variant.
How many loops are handled by one SE4307T01?
Each CHARM serves one field channel in the electronic-marshalling architecture.
Which hardware must accompany this IS CHARM?
Use the approved IS baseplate and terminal block selected for the project.
What should be tested after replacing the analog-input CHARM?
Verify loop current, engineering scaling, HART communication, diagnostics and fail-state behavior.
Can SE4307T01 be substituted for SE4306T01?
No. SE4307T01 is analog input with HART, whereas SE4306T01 is a 45 mA discrete output.