Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
How We Verify Your Order
Before dispatch, we confirm the exact model, revision, condition, inspection requirements and shipping documents for your order.
See a real on-site verification case >>
  • Lifecycle status

    Active / Available from OEM
    Apter Power provides quotations, technical documents, sourcing support and GEM 80 system guidance.

8200-4006/8607-4001

/ 4.9
1001 reviews | Need a Specific Revision?
GEC Industrial Controls 8200-4006/8607-4001 is a GEM 80 Basic Processor and Personality Module assembly with visible memory, battery and port indications.
In Stock
Ships by Saturday, November 14
Fast Shipping Available
Get a quick price for 8200-4006/8607-4001
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 8200-4006/8607-4001

  • Manufacturer:
    GEC Industrial Controls
  • Part Number:
    8200-4006/8607-4001
  • Product Family:
    GEM80 Series
  • Product Type:
    GEM 80 Basic Processor and Personality Module Assembly
  • Stock:
    1
  • Front-panel designation:
    BASIC PROCESSOR
  • Companion board marking:
    PERSONALITY MODULE
  • Visible status indicators:
    MEMORY ERROR; BATTERY FAIL
  • Visible interface labels:
    PORT 1; PORT 2
  • Assembly form:
    Stacked dual-PCB plug-in assembly
  • Weight:
    0.8 kg
  • Estimated shipping dimensions:
    24.5 x 23.7 x 4 cm
  • Tariff Code:
    8537101190
  • Country of origin:
    United Kingdom
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Processor Assembly Front Panel Service Handling Product Applications

Features:

  • Paired assembly: Combines a BASIC PROCESSOR front panel with a PERSONALITY MODULE companion board.
  • Visible diagnostics: Provides MEMORY ERROR and BATTERY FAIL indications on the front panel.
  • Front interfaces: Carries PORT 1 and PORT 2 markings plus a visible D-sub connector.
Assembly decision: Keep the paired 8200-4006 and 8607-4001 boards together during service.

Documentation decision: Capture the rack position, connectors, port cables and indicator state before removal.

Startup decision: Use the approved GEM 80 sequence and verify processor and communication functions after installation.

Apter Power supports GEC Industrial Controls 8200-4006/8607-4001 quotations, available technical documents and GEM 80 system guidance.
GEC Industrial Controls 8200-4006/8607-4001 GEM 80 Basic Processor and Personality Module Assembly Manuals,Datasheets,Link Important Notice: Manuals, software, cables, calibration data and accessories are included only when listed in the quotation.
  • Front-panel section: The visible faceplate is marked BASIC PROCESSOR.
  • Companion board: The stacked upper board is marked PERSONALITY MODULE.
  • Board arrangement: The two PCBs form one supported plug-in assembly.
  • Rack connection: Protect the backplane contacts and inter-board connections during handling.
  • Memory indication: MEMORY ERROR provides a visible diagnostic state.
  • Battery indication: BATTERY FAIL provides a visible service indication.
  • Port markings: PORT 1 and PORT 2 distinguish the front connections.
  • D-sub connector: Use cabinet documentation for the connector protocol and pinout.
  • Isolation: Use the approved GEM 80 shutdown and zero-energy procedure.
  • ESD control: Handle the complete assembly at a grounded workstation.
  • Cable documentation: Label every port cable before disconnection.
  • Mechanical support: Support both boards without loading the front connector or rack contacts.
  • GEM 80 processing: Supports installed racks using the exact paired processor assembly.
  • Hardware personality: Retains the installed companion-board configuration.
  • Maintenance diagnostics: Uses visible memory, battery and port indications during service.
Description
The 8200-4006/8607-4001 is a GEC/CEGELEC GEM 80 plug-in processor assembly whose visible front panel is marked BASIC PROCESSOR and whose companion board is marked PERSONALITY MODULE. The paired markings identify the processor board and personality board as one installed assembly.

On 8200-4006/8607-4001, the front panel provides MEMORY ERROR and BATTERY FAIL indications together with PORT 1 and PORT 2 markings. A front D-sub connector is visible, but its communication protocol and pinout are not stated on the product and are therefore not assigned on this page.

Before maintenance involving 8200-4006/8607-4001, document the stacked-board arrangement, rack position, cable connections and indicator state, then use ESD-controlled handling for the complete assembly. Apter Power can provide quotations, available technical documents and GEM 80 system guidance.
Alternative Names
8200 4006 / 8607 4001 82004006 86074001 GEC 8200-4006/8607-4001 Cegelec 8200-4006/8607-4001 GEM 80 8200-4006/8607-4001 8200-4006 8607-4001 Basic Processor GEM80 8200 4006 8607 4001 8607-4001/8200-4006
Technical notes
User-supplied product photographs confirm the paired 8200-4006 and 8607-4001 markings, BASIC PROCESSOR front panel, PERSONALITY MODULE board, MEMORY ERROR and BATTERY FAIL indicators, PORT 1 and PORT 2 labels, and a stacked plug-in construction. No manufacturer-authored exact-model manual was located, so protocol, memory capacity, processor speed and connector pinout are intentionally omitted.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What should be recorded before 8200-4006/8607-4001 is removed from a GEM 80 rack?
Photograph the assembly in position and record the rack slot, both board markings, connector orientation, port cables, indicator state and any cabinet drawing reference.
How should a MEMORY ERROR indication on 8200-4006/8607-4001 be investigated?
Record the indication before power is removed, review the GEM 80 cabinet diagnostics and documentation, and check seating, power and the paired-board connection before disturbing programmed hardware.
What should be checked when BATTERY FAIL is shown on 8200-4006/8607-4001?
Follow the approved GEM 80 battery-service procedure, preserve any required program or configuration information and verify the indication after controlled restart.
How should the stacked boards of 8200-4006/8607-4001 be handled on a bench?
Use a grounded ESD workstation, support both boards together and protect their inter-board connections, rack contacts and front-panel connector from mechanical load.
How should PORT 1 and PORT 2 cables be restored on 8200-4006/8607-4001?
Label and photograph every cable before removal, restore each connector to its documented port and complete the system communication checks required by the cabinet procedure.
What should commissioning confirm after 8200-4006/8607-4001 is installed?
Confirm full seating, secure front-panel hardware, restored cable routing, normal indicator state and the documented processor and communication functions under controlled startup.