Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Discontinued / Obsolete by OEM
    Apter Power assists with IC670MDL330 quotation enquiries and official technical files.

IC670MDL330

/ 4.9
1001 reviews | Need a Specific Revision?
General Electric IC670MDL330 is a 16-point 12–120 VAC grouped discrete output module rated 1 A per point for Field Control stations.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for IC670MDL330
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IC670MDL330

  • Manufacturer:
    General Electric
  • Part Number:
    IC670MDL330
  • Product Family:
    GE Genius I/O
  • Product Type:
    12–120 VAC 1.0 A Discrete Output Module
  • Stock:
    1
  • Output Points:
    16 outputs in one group
  • Load Voltage:
    10–132 VAC, 47–63 Hz
  • Point Current:
    1 A maximum
  • Module Current:
    4 A maximum
  • Inrush Current:
    10 A for one cycle
  • Minimum Load:
    10 mA
  • On-State Drop:
    2 V maximum
  • BIU Current:
    275 mA maximum with all outputs on
  • Estimated shipping dimensions:
    8.2 x 5.25 x 7.3 cm
  • Tariff Code:
    8538900000
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Load Ratings Protection Switching

Features:

  • Switches sixteen 12–120 VAC loads from a single grouped output assembly.
  • Combines a 1 A point rating with a 4 A total module limit.
  • Handles 10 A one-cycle inrush while snubber networks protect the solid-state output paths.
IC670MDL330 switches sixteen AC loads from one field group over a 10–132 VAC, 47–63 Hz operating range.

The 1 A point rating and 4 A module limit must be considered together when several outputs are energized simultaneously.

Each solid-state path includes snubber protection, supports a 10 A one-cycle inrush, and changes state within half an AC cycle.

Even after OEM End-of-Life (EOL), the General Electric IC670MDL330 12–120 VAC 1.0 A Discrete Output Module may still be sourced and supported through Apter Power.
General Electric IC670MDL330 12–120 VAC 1.0 A Discrete Output Module Manuals,Datasheets,LinkImportant Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
General Electric IC670MDL330 12–120 VAC 1.0 A Discrete Output Module Specs

General

  • ManufacturerGeneral Electric
  • ModelIC670MDL330
  • ConditionNew Original ready stock
  • Product FamilyGE Genius I/O
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Grouped AC Load Capacity:

  • Output capacity: 16 AC output points in one group
  • Load range: 10–132 VAC at 47–63 Hz
  • Point current: 1 A maximum per output
  • Module current: 4 A maximum across all outputs

Output Load Protection:

  • Inrush capability: 10 A for one AC cycle
  • Minimum load: 10 mA
  • Snubber network: Each solid-state output includes load-transient suppression
  • On-state drop: 2 V maximum

AC Output Switching Behavior:

  • State response: Output changes occur within one-half AC cycle
  • BIU current: 275 mA maximum with all outputs on
  • Field grouping: All sixteen loads share one output group
  • System interface: Field Control Bus Interface Unit
Description
Sixteen solid-state outputs on IC670MDL330 switch AC loads from a single field group across the 10–132 VAC, 47–63 Hz operating range.

Each point is rated 1 A, while total module load is limited to 4 A. The outputs tolerate a 10 A one-cycle inrush and exhibit no more than a 2 V on-state drop.

Integral snubbers protect the switching paths and response remains under one-half AC cycle, making the module suitable for grouped contactor, lamp, and solenoid loads within the published current limits.
Alternative Names
IC 670 MDL 330 IC-670-MDL-330 GE IC670MDL330 GE Fanuc IC670MDL330 General Electric IC670MDL330 IC670 MDL330 IC670MDL 330 IC670MDL330 12–120 VAC 1.0 A Discrete Output Module
Technical notes
IC670MDL330 uses the published Field Control channel grouping, electrical limits, response behavior, and BIU load.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What output loading limit applies to each IC670MDL330 point?
Each IC670MDL330 output is rated up to 1 A, subject to the documented IC670MDL330 module loading limits.
How are the IC670MDL330 outputs electrically arranged?
IC670MDL330 provides 16 AC outputs in one group, so the IC670MDL330 common and load wiring must suit a grouped arrangement.
Can IC670MDL330 handle short starting-current surges?
IC670MDL330 is documented for a 10 A surge for one cycle, while normal point and module limits still apply.
Which AC source range is supported by IC670MDL330?
IC670MDL330 supports 10–132 VAC at 47–63 Hz.
What should be verified before replacing an IC670MDL330 module?
Before replacing IC670MDL330, verify the Field Control BIU, terminal block, grouped common, load current, field voltage, and exact order code.
What total module loading is documented for IC670MDL330?
IC670MDL330 is documented for up to 4 A total module output current.
How can a buyer request IC670MDL330 technical files and pricing?
A buyer can request an IC670MDL330 quotation and applicable official technical documentation from Apter Power.