Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Discontinued / Obsolete by OEM
    Apter Power reviews Genius network and terminal-block matching for quotation.

IC670GBI001

/ 4.9
1001 reviews | Need a Specific Revision?
General Electric IC670GBI001 is a Genius Bus Interface Unit for a Field Control Distributed I/O station on a Genius network.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for IC670GBI001
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IC670GBI001

  • Manufacturer:
    General Electric
  • Part Number:
    IC670GBI001
  • Product Family:
    GE Genius I/O
  • Product Type:
    Genius Bus Interface Unit
  • Stock:
    1
  • Network:
    Genius serial bus
  • Configuration Storage:
    Nonvolatile memory in terminal block
  • Host Function:
    Station I/O data exchange
  • Diagnostics:
    Network and I/O fault reporting
  • Service Access:
    Local status and configuration support
  • Mounting Arrangement:
    Separate Bus Interface Unit terminal block
  • Tariff Code:
    8517623990
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Genius Network Station Control Installation

Features:

  • Provides the Genius bus interface for an IC670 Field Control station
  • Coordinates station data exchange with a Genius-capable host
  • Separates the removable interface module from the retained terminal assembly
IC670GBI001 occupies the network-facing position in a Field Control station, presenting the local I/O group to the Genius bus rather than acting as an individual field channel.

Station servicing should begin with the complete catalog number and hardware revision because later Genius Bus Interface Unit variants are documented separately and are not interchangeable solely on the basis of appearance.

Configuration records, bus settings, terminal-block wiring, and active diagnostics should be captured before module removal so the replacement can be checked against the original station arrangement.

Apter Power can review Genius network, terminal assembly, and revision matching for the General Electric IC670GBI001 Genius Bus Interface Unit.
General Electric IC670GBI001 Genius Bus Interface Unit Manuals, Datasheets, Links
General Electric IC670GBI001 Genius Bus Interface Unit Specs

General

  • ManufacturerGeneral Electric
  • ModelIC670GBI001
  • ConditionNew Original ready stock
  • Product FamilyField Control Distributed I/O

Genius station interface

  • Bus role: Connects the Field Control station to the Genius serial bus.
  • Host side: Requires a Genius-capable PLC, controller, or computer interface.
  • Data path: Carries station input, output, and diagnostic information between the host and local modules.
  • Matching: Bus address, baud rate, and host configuration must agree with the installed network.

Field Control station duties

  • I/O coordination: Manages the station-level exchange for the connected Field Control modules.
  • Configuration: Station settings should be documented before a module change.
  • Diagnostics: Network and module faults should be reviewed together during troubleshooting.
  • Revision control: Use the complete IC670GBI001 catalog and revision when selecting a replacement.

Pre-installation verification

  • Terminal assembly: Confirm the Bus Interface Unit terminal block and retained wiring are undamaged.
  • Genius wiring: Verify bus polarity, shielding, termination, and continuity before startup.
  • Station records: Restore only the configuration approved for the installed I/O arrangement.
  • Commissioning: Check power, interface status, host communication, and each I/O module after replacement.
Description
The IC670GBI001 is a Genius Bus Interface Unit for connecting Field Control I/O modules to a host PLC or computer over a Genius bus. The interface manages station communications and transfers input and output data during each bus scan.

General Electric designed the IC670GBI001 as an intelligent station interface with configuration storage, diagnostic processing, selectable defaults, and analog-module support. A hand-held interface provides local access for setup and status review.

The IC670GBI001 mounts on a separate Bus Interface Unit terminal block so field power, bus wiring, and station configuration remain associated with the terminal assembly. This arrangement supports service work without rewiring the complete I/O station.
Alternative Names
IC 670 GBI 001 IC-670-GBI-001 GE IC670GBI001 GE Fanuc IC670GBI001 General Electric IC670GBI001 IC670 GBI001 IC670GBI 001 IC670GBI001 Genius Bus Interface Unit
Technical notes
IC670GBI001 provides the Genius network interface between a Field Control I/O station and its host bus controller.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How does IC670GBI001 fit into a Field Control station?
IC670GBI001 serves as the station bus interface, linking the installed Field Control I/O modules with the host Genius network.
Which network must be present for IC670GBI001?
IC670GBI001 is intended for a Genius serial bus and should be matched to a host controller or computer that supports Genius communications.
Can IC670GBI001 be selected only by its IC670 prefix?
No. IC670GBI001 must be matched by the complete catalog number because other IC670 bus interface units use different networks, power arrangements, or revisions.
What should be recorded before removing IC670GBI001?
Record the Genius bus settings, station configuration, terminal-block wiring, and observed diagnostics for IC670GBI001 before replacement work begins.
Does IC670GBI001 require the field wiring to be moved with the module?
IC670GBI001 uses a separate Bus Interface Unit terminal block, so verify that the retained terminal assembly and its wiring are suitable before installing a replacement module.
Which checks help diagnose an IC670GBI001 communication problem?
For IC670GBI001, check bus continuity, node configuration, host status, station power, module indicators, and any reported I/O diagnostics.
What information is useful when requesting IC670GBI001?
Provide the complete IC670GBI001 catalog number, hardware revision, terminal-block details, installed host, and Genius network configuration.