Features:
- Sixteen circuits can be configured individually as inputs or outputs
- 24 VDC sink circuitry is intended for distributed field wiring
- Block and circuit LEDs support local status checks
IC660BBD023 identifies the 24 VDC sink configuration within the sixteen-circuit Genius discrete I/O group, with a dedicated terminal assembly for its field connections.
At the point of control, the block exchanges discrete states over the Genius bus while carrying out input processing, output switching, and local fault reporting.
Commissioning should verify DC polarity, common wiring, bus termination, per-point load current, output defaults, and the configured device address before field power is applied.
The General Electric IC660BBD023 24 VDC 16-Circuit Sink I/O Block is available for quotation, official documentation, configuration review, and system-matching support from Apter Power.
General Electric IC660BBD023 24 VDC 16-Circuit Sink I/O Block Manuals, Datasheets, Links
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
General Electric IC660BBD023 24 VDC 16-Circuit Sink I/O Block Specs
General
- ManufacturerGeneral Electric
- ModelIC660BBD023
- ConditionNew Original ready stock
- Product FamilyGE Genius I/O
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Point assignment
- I/O selection: Configure each of the sixteen circuits for the required input or output role.
- Sink wiring: Arrange the external DC supply and load return for sink operation.
- Output defaults: Define the commanded state used if bus communication is lost.
- Indicators: Use the circuit LEDs to compare field voltage with commanded logic.
Fault visibility
- Block health: Unit OK and I/O Enabled LEDs indicate electronics and network status.
- Output protection: Electronic protection limits damage from abnormal output loading.
- Fault reporting: Enabled diagnostics are communicated to the controlling Genius interface.
- Service check: Clear a fault only after its field cause has been corrected.
Network preparation
- Device number: Assign a unique Genius bus address before connection.
- Baud rate: Match the block setting to the existing Genius network.
- Bus cable: Preserve conductor polarity, shielding, and daisy-chain continuity.
- Termination: Apply the documented impedance only at the two physical bus ends.