Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power provides IC5008TAW1000 quotation support and customer access to the appropriate official General Electric technical documentation when available.

IC5008TAW1000

/ 4.9
1001 reviews | Need a Specific Revision?
General Electric IC5008TAW1000 is an 18.1-inch Machine Edition development and runtime Panel PC providing an SXGA interface for projects licensed to 8000 I/O.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for IC5008TAW1000
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IC5008TAW1000

  • Manufacturer:
    General Electric
  • Part Number:
    IC5008TAW1000
  • Product Family:
    GE Intelligent Platforms
  • Product Type:
    18.1-Inch Machine Edition Development and Runtime Panel PC
  • Stock:
    1
  • Display:
    18.1 in TFT color touchscreen
  • Native resolution:
    1280 x 1024 SXGA
  • Display colors:
    64K
  • Brightness:
    250 cd/m2
  • Processor:
    750 MHz
  • Memory:
    128 MB
  • Hard drive:
    13 GB
  • Optical drive:
    CD-ROM
  • Operating system:
    Windows 2000
  • Application software:
    CIMPLICITY Machine Edition View and Logic Developer PC development and runtime
  • Machine Edition capacity:
    8000 I/O
  • Ethernet:
    Two 10/100BaseT RJ45 ports
  • Serial interfaces:
    COM1, COM2, COM3; touchscreen on COM4
  • USB:
    Two ports, one front and one side
  • Expansion:
    Two shared ISA/PCI and one PCI
  • Power input:
    100-240 VAC, 50-60 Hz
  • Power consumption:
    67 W typical, 75 W maximum
  • Operating temperature:
    0 to 40 deg C
  • Storage temperature:
    -20 to 60 deg C
  • Humidity:
    10-85% non-condensing
  • Front protection:
    NEMA 4 and IP65
  • Agency approvals:
    UL 1604 Class I, Division 2; CE
  • Weight:
    24.25 lbs (11 kg)
  • Estimated shipping dimensions:
    442 x 371 x 160 mm
  • Tariff Code:
    8471414000
  • Country of origin:
    United States
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Large-Screen Editing License Scope Connectivity Plan Recovery Readiness

Features:

  • 18.1-inch SXGA platform combining Machine Edition development and runtime.
  • View and Logic Developer PC license supporting up to 8000 I/O points.
  • Large-screen industrial station with dual Ethernet and full-length expansion.
A single panel can host project-development tools and then execute the resulting runtime application on the installed operator display.

The largest screen in the series provides 1280 x 1024 native resolution, supporting dense process pages and extensive engineering dialogs.

Full-length cards, two Ethernet adapters, and external serial connections let the engineering station interface with a broad legacy control architecture.

Apter Power can assist with pricing and official technical documentation for the General Electric IC5008TAW1000 18.1-Inch Machine Edition Development Panel PC.
General Electric IC5008TAW1000 18.1-Inch Machine Edition Development and Runtime Panel PC Manuals, Datasheets, Links
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

IC5008TAW1000 Engineering Interface

  • Native canvas: The SXGA panel supplies a 1280 x 1024 project workspace.
  • Touch selection: The resistive overlay provides direct interaction with editors and runtime controls.
  • Front shortcuts: Panel keys expose task switching, right-click, hot-key, brightness, and soft-keyboard functions.
  • Service peripherals: PS/2 keyboard and mouse ports support longer configuration sessions.

IC5008TAW1000 Machine Edition Capacity

  • Development rights: The order code includes supported View and Logic PC project creation.
  • Runtime rights: The development system also executes the configured application.
  • I/O ceiling: The licensed project may collect as many as 8000 device points.
  • Counting rule: PLC and CNC values count toward the total, unlike ordinary internal virtual points.

IC5008TAW1000 Control-System Links

  • Ethernet paths: Two 10/100BaseT adapters provide separate network connections.
  • Serial devices: Three external RS232 ports support point-to-point equipment.
  • Internal options: ISA/PCI positions accept supported communication or control cards.
  • Address records: Fixed addresses, DHCP choices, domains, and workgroups are documented before replacement.

IC5008TAW1000 Restoration Materials

  • Project archive: A current Machine Edition backup is stored separately from the panel.
  • Operating image: Recovery media returns the station to its supplied Windows state.
  • Driver set: Graphics, network, touch, chipset, and front-key packages are retained.
  • License record: Software license and I/O-capacity information accompany the project archive.
Description
IC5008TAW1000 combines an 18.1-inch SXGA operator interface with CIMPLICITY Machine Edition View and Logic Developer PC development and runtime software. The supplied license supports as many as 8000 device I/O points.

The 750 MHz standard computer in IC5008TAW1000 runs Windows 2000 with 128 MB memory and a 13 GB hard disk. CD-ROM and floppy drives retain compatibility with the software and project media used by this platform generation.

Its 1280 x 1024 workspace allows IC5008TAW1000 to present large process graphics while also providing room for project-development tools. The integrated touch surface and front control keys keep routine interaction at the cabinet door.

Three expansion positions and dual Ethernet interfaces broaden the station's connectivity for control, engineering, and supervisory networks. Cabinet design for IC5008TAW1000 must also carry the higher power and cooling requirements of the 18-inch chassis.
Alternative Names
IC5008-TAW1000 IC5008-TAW-1000 IC5008 TAW1000 IC 5008 TAW 1000 IC5OO8TAW1000 IC5008TAW1OOO 1C5008TAW1000 GE Fanuc IC5008TAW1000
Technical notes
IC5008TAW1000 uses a 4 MB SDRAM VGA controller for its SXGA panel, distinguishing its display hardware from the smaller models.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Can IC5008TAW1000 run the same project it develops?
IC5008TAW1000 includes both development and runtime rights for supported Machine Edition View and Logic PC applications.
What should be checked when an IC5008TAW1000 project approaches its license limit?
Review the collected device points in IC5008TAW1000 because PLC and CNC values count toward the 8000-I/O allowance while ordinary virtual points do not.
Which files are important when migrating IC5008TAW1000?
IC5008TAW1000 migration requires the project archive, license details, network settings, communication drivers, and records of installed expansion hardware.
How is touch input connected inside IC5008TAW1000?
IC5008TAW1000 routes the analog resistive touchscreen internally to COM4 at IRQ 10.
Why does IC5008TAW1000 open a project in the wrong screen layout after recovery?
Restore the IC5008TAW1000 graphics driver and its native 1280 x 1024 mode before evaluating the Machine Edition project layout.
Can IC5008TAW1000 be installed in a hazardous area?
IC5008TAW1000 follows the UL 1604 Class I, Division 2 power-clamp and nonincendive wiring requirements when used in the approved environment.
Why should IC5008TAW1000 cooling be checked after adding a card?
IC5008TAW1000 already has the highest base heat load in this panel range, and added cards must remain inside both the 20 W allowance and required cabinet airflow.